IMPORTANT INFORMATION
For any installation problem please contact our Customer
Serviceat the 39-0172.812411 operating Monday to
Fridayfrom 8:30 to 12:30 and from 14:00 to 18:00
V2 reserves the right to make modifications to the product
without any prior warning; furthermore, the company
declines all responsibility for damages to people or property
resulting from improper use or incorrect installation.
m
Read the following instruction manual thoroughly
prior to proceeding with installation and programming of
the system.
• This instruction manual is intended solely for use by technical
staff, qualified in the field of installation of automation devices
• None of the information contained in the manual is of interest
or use to end users.
• All maintenance or programming operations should be
conducted exclusively by qualified staff.
The installation, testing and commissioning of door and gate
automation devices should be performed by qualified and skilled
personnel, who must assume responsibility for setting up the
tests envisaged depending on the risks present; and verify
compliance in accordance with legal and regulatory requirements.
• V2 accepts no responsibility for injuries and damage resulting
from improper use of the product; other than that described in
this manual.
• Packing materials must be disposed of in full compliance with
local regulations.
EU DECLARATION OF CONFORMITY
The manufacturer V2 S.p.A., headquarters in Corso Principi di
Piemonte 65, 12035, Racconigi (CN), Italy
Under its sole responsibility hereby declares that the products:
WES
comply with the following directives:
2014/53/EU, ROHS-3 2015/863/EU
Racconigi, 01/06/2019
Legal representative, V2 S.p.A.
Sergio Biancheri
TECHNICAL INFORMATION
DESCRIPTION
WES (Wireless Edge System) is the new V2 system allowing safety
edges to be controlled by radio.
The system consists of a base unit connected directly to the
control unit, and one or more sensors (up to 8 per base unit)
connected to the safety edges.
The base unit is powered from the control unit and constantly
monitors the status of the sensors connected.
Up to a maximum of 8 sensors may be connected to each base
unit.
The system is compatible with standard safety edges with NC
breakers, resistive safety edges (8k2).
The system is compatible with all control unit models.
System operation
The system operates independently of the status of the control
unit. The relay corresponding to each sensor unit is kept closed if
no edges are activated.
If an edge is pressed, the relay opens, signalling the anomaly to
the control unit.
The base unit communicates with each sensor every 15 seconds,
so as to verify their presence and function.
Sensor
Power supply:
2 LR6/AA batteries (1.5 V-2600 mAh)
Stand-by time:
>2 years
Dimensions:
170,5x45x19,5 mm
Operating temperature: -15/+50 °C
Inputs:
2 mechanical or resistive edges
Maximum range:
10 m