background image

PROGRAMMING

36

Press the  MENU key to confirm, on the
display will appear: LUCi.

If the function is CiCL, on the display will
appear: LUCi.

FLASHLIGHT IN PAUSE

This menu permits to activate or to disactivate
the flashlight during the pause time.

Press the keys UP or DOWN until the display
shows:

Press the MENU key,the display shows one
of the 2 writings:

no

not activated flashlight in pause

Si

activated flashlightin in pause

Press the MENU key,the display shows one
of the 2 writings.

Press the  MENU key to confirm, on the
display will appear: LP.PA.

FLASHLIGHT WITH

 INTERMITTENCE

The control unit PD2 permits the connection
of a flashlight with or without intermittence.If
the flashlight is equipped with an inner
intermittence effect, it is necessary to select
the option "Si", but if it has no inner
intermittence, it is necessary to select the
option "no" in oder to make it flash.

Press the keys UP or DOWN until the display
shows:

Press the MENU key,the display shows one
of the 2 writings.

no

if the flashlight has no inner
intermittence

Si

the clock function is activated

Set the wished functions pressing the UP or
DOWN keys.

Press the  MENU key to confirm, on the
display will appear: in.LP.

CLOCK FUNCTION

This function permits to program the time
bands of opening and closing. It is necessary
to connect a 24h timer with a contact
normally open in parallel with the START
or PEDONAL START input. When the ti-
mer contact is closed, the gate gets into
opening phase and remains opened until the
contact of the timer opens causing the
re-closing of the gate.

IMPORTANT: 

FOR A CORRECT

FUNCTIONING IT IS NECESSARY TO
ACTIVATE THE AUTOMATIC CLOSING
(menu Ch.AU.)

Press the keys UP or DOWN until the display
shows:

Press the MENU key,the display shows one
of the 2 writings:

GB

PROGRAMMING

37

no

the clock function is not activated

Si

the clock function is activated

Set the wished functions pressing the UP or
DOWN keys.

Press the  MENU key to confirm, on the
display will appear oroL.

BRAKE

This menu enables the activation of the brake
function by which it is  possible to avoid
unproper motion of the gate after impulse or
safety intervention ( the gate continues
moving instead of immediately stopping).
This inconvenience occurs when a plate-
clutch motor is employed on a very heavy
gate: because of the inertia, the gate does not
stop immediately but keeps moving for a few
dozens centimetres undermining its safety.

Press UP or DOWN, until the display shows:

Press MENU, the display shows:

no

the brake function is disconnected

Si

the brake function is activated

Press UP or DOWN to select the wished function.

Press  MENU to confirm: the display
shows: FrEn.

INPUT STOP

This menu permits to select the functions
associated to the command of STOP.
Press the  UP or  DOWN keys until on the
display appears:

Press the MENU key,the display shows one
of the 3 writings:

no

the input STOP is not available

ProS

the input STOP stops the gate:
pressing the command START the
gate continues the motion

invE

the command STOP stops the
gate: at the next START the gate
starts moving in the opposite
direction.

NOTE: During the pause STOP stops the
gate: pressing the command START will
always re-closing the gate.

Press  UP or Down to select the wished
function.

Press menu to confirm. the display shows
StoP.

INPUT PHOTO 1

The photocell 1 (contact normally closed) is
a safety device which is active during opening
and closing: the intervention of the photocell
during the closing halts the gate, after the
photocell is cleared the gates reverses the

GB

Содержание PD2

Страница 1: ...OCELL IN PAUSE 33 AUTOMATIC CLOSING 34 COURTESY LIGHTS 34 FLASHLIGHT IN PAUSE 36 FLASHLIGHT WITH INTERMITTENCE 36 GB 27 INDEX CLOCK FUNCTION 36 BRAKE 37 INPUT STOP 37 INPUT PHOTO 1 37 INPUT PHOTO 2 38...

Страница 2: ...SERTION GB PROGRAMMING 29 PROGRAMMING PD2 has a menu programming structure Each menu corresponds to a function of the unit function menu or to the setting of a working time time menu The time menus en...

Страница 3: ...MENU key to confirm the display shows the writing t APP CLOSING TIME This menu is adjustable from 0 to 120 seconds 0 5 which is the closing time for gate To avoid the uncompleted closing of the gate w...

Страница 4: ...gate APEr the command START open the gate Press the MENU key the display shows one of the 2 writings GB PROGRAMMING 33 Press the MENU key to confirm on the display will appear St Ch START IN PAUSE Th...

Страница 5: ...5 PD2 control unit enables the connection of the courtesy lights I E garden lights which can work automatically lights on for the whole cycle or timed lights on for a time adjustable from 0 to 999 sec...

Страница 6: ...ess the keysUP orDOWN until the display shows Press the MENU key the display shows one of the 2 writings GB PROGRAMMING 37 no the clock function is not activated Si the clock function is activated Set...

Страница 7: ...d the intervention of the rib 1 during closing blocks the gate the next START or START P restores the closing PressUP or DOWN until the display shows GB PROGRAMMING 39 Press MENU the display shows eit...

Страница 8: ...e channel in which it is memorized Ex tEL3 INPUT RADIO 2 tEL2 PressUP or DOWN until the display shows GB PROGRAMMING 41 Press MENU the display shows Press and keep pressed the button of the transmitte...

Страница 9: ...acilitate the connections the PD2 control unit is equipped with two entirely removable terminal blocks 1 Antenna masquade 2 Antenna shield 3 Opening control for the connection of push button panel key...

Страница 10: ...t AP1 t AP2 etc will be appear press UP key to flow the chart from the bottom to the top press MENU key to flow the chart horizontally for example if the t ChP function is displayed by pressing the M...

Страница 11: ...Start off Si 8 St AP no ChiU PAUS Start in opening START command is not available command close the gate stop the gate and goes in Pause PAUS 9 St Ch Stop APEr Start in closing command START stop the...

Страница 12: ...he motion STOP command stops the gate START command starts moving in the opposite direction no 20 Fot 1 no APCh Input PHOTO 1 not available photocell active during the opening the closing no 21 Fot 2...

Отзывы: