![V2 ELETTRONICA PD2 Скачать руководство пользователя страница 11](http://html2.mh-extra.com/html/v2-elettronica/pd2/pd2_manual_3094898011.webp)
FUNCTION CHART
46
GB
FUNCTION TABLE PD2
47
N. DISPLAY
DATAS
DESCRIPTION
DEFAULT
DATAS
MEMO
DATAS
0
dEF
no/Si
Load V2 standard datas
no
1
t.AP
0 - 120 s
Opening time
22.5
2
t.APP
0 - t.AP1
Opening time of pedestrian gate
6.0
3
t.Ch
0 - 120 s
Closing time
23.5
4
t.ChP
0 - t.Ch1
Closing time of pedestrian gate
7.0
5
t.PrE
0 - 120 s
Pre-flashing time
1.0
6
Pot.
30 to 100% Motor power
40
7
SPUn
no/Si
Start off
Si
8
St.AP
no
ChiU
PAUS
Start in opening
- START command is not available
- command close the gate
- stop the gate and goes in Pause
PAUS
9
St.Ch
Stop
APEr
Start in closing
- command START stop the gate
- command START open the gate
StoP
10
St.PA
no
chiU
Start in pause
- START command is not available
- START command closes the gate
ChiU
11
SP.AP
no
ChiU
PAUS
Pedestrian in opening
- P START command is not available
- P START closes the gate
- gate goes in pause
PAUS
12
Ft.PA
rPAU
t.PCh
Photocell in pause
- Pause time recharged
- gate stop for a time to be set
between 0 to 120 seconds
r.PAU