PROGRAMMING

30

Press  MENU key: the display shows  no.

Select the option Si pressing UP or DOWN.

Press  MENU key to confirm: the display
shows the control panel.

The default standard data have been
memorized and the control unti is ready to
be used.

PERSONALIZED PROGRAMME

This type of programme enables you to
change the working times and all the main
functions, according to the user's
requirements: by pressing UP or DOWN keys
is possible to select the wished menu (For a
quick shifting keep the key pressed. After the
amendment, press the key "END OF
PROGRAMMING" and quit: the new data
has been memorized.
ATTENTION: in case no inputs are made for
more than 1 minute, the control box goes
automatically out from the programme and
the amendment are not memorized.

OPENING TIME

This menu is adjustable from 0 to 120 seconds
(±0,5) and determines the time for the
opening of the gate.

Press  UP or DOWN keys, until the display
shows:

Press the  MENU key, the display shows:

Set the wished time pressing the  UP or
DOWN keys.

Press the MENU key to confirm:the display
shows the writing: t.AP.

OPENING TIME OF PEDESTRIAN GATE

This menu is adjustable from 0 seconds to
t.AP (±0,5) and determines the opening time
of gate.

Press  UP or DOWN keys, until the display
shows:

Press the  MENU key, the display shows:

Set the wished time pressing the  UP or
DOWN keys.

Press the MENU key to confirm:the display
shows the writing: t.APP.

CLOSING TIME

This menu is adjustable from 0 to 120
seconds(±0,5) which is the closing time for
gate. To avoid the uncompleted closing of
the gate, we suggest to set a longer opening
time of t.AP.

GB

PROGRAMMING

31

Press  UP or DOWN keys, until the display
shows:

Press the  MENU key,the display shows:

Set the wished time pressing the  UP or
DOWN keys.

Press the MENU key to confirm:the display
shows the writing t.Ch.

CLOSING OF PEDESTRIAN GATE

This menu is adjustable from 0 to t.Ch (±0.5)
and determines the closing time of gate. In
order to avoid the uncompleted closing of the
gate, we suggest to set a longer opening time
of t.APP.

Press  UP or DOWN keys, until the display
shows:

Press theMENU key, the display shows:

Set the wished time pressing the  UP or
DOWN keys.

Press the  MENU key to confirm: on the
display will appear: t.ChP.

PRE-FLASHING TIME

This menu permits the introduction of a pre-
flashing that occurs before any movement of
the gate either in opening or in closing phase:
the time of pre-flashing can be adjusted from
0 to 120 seconds (± 0,5).

Press the keys UP or DOWN until the display
shows:

Press the  MENU key,the display shows:

Set the wished time pressing the  UP or
DOWN keys.

Press the  MENU key to confirm, on the
display will appear t.PrE.

MOTOR POWER

This menu permits to adjust the motor power
from 30 to 100% with a scanning of ±0,5.

Press the keys UP or DOWN until the display
shows:

Press the  MENU key,the display shows:

Set the wished value pressing the  UP or
DOWN keys.

GB

Содержание PD2

Страница 1: ...OCELL IN PAUSE 33 AUTOMATIC CLOSING 34 COURTESY LIGHTS 34 FLASHLIGHT IN PAUSE 36 FLASHLIGHT WITH INTERMITTENCE 36 GB 27 INDEX CLOCK FUNCTION 36 BRAKE 37 INPUT STOP 37 INPUT PHOTO 1 37 INPUT PHOTO 2 38...

Страница 2: ...SERTION GB PROGRAMMING 29 PROGRAMMING PD2 has a menu programming structure Each menu corresponds to a function of the unit function menu or to the setting of a working time time menu The time menus en...

Страница 3: ...MENU key to confirm the display shows the writing t APP CLOSING TIME This menu is adjustable from 0 to 120 seconds 0 5 which is the closing time for gate To avoid the uncompleted closing of the gate w...

Страница 4: ...gate APEr the command START open the gate Press the MENU key the display shows one of the 2 writings GB PROGRAMMING 33 Press the MENU key to confirm on the display will appear St Ch START IN PAUSE Th...

Страница 5: ...5 PD2 control unit enables the connection of the courtesy lights I E garden lights which can work automatically lights on for the whole cycle or timed lights on for a time adjustable from 0 to 999 sec...

Страница 6: ...ess the keysUP orDOWN until the display shows Press the MENU key the display shows one of the 2 writings GB PROGRAMMING 37 no the clock function is not activated Si the clock function is activated Set...

Страница 7: ...d the intervention of the rib 1 during closing blocks the gate the next START or START P restores the closing PressUP or DOWN until the display shows GB PROGRAMMING 39 Press MENU the display shows eit...

Страница 8: ...e channel in which it is memorized Ex tEL3 INPUT RADIO 2 tEL2 PressUP or DOWN until the display shows GB PROGRAMMING 41 Press MENU the display shows Press and keep pressed the button of the transmitte...

Страница 9: ...acilitate the connections the PD2 control unit is equipped with two entirely removable terminal blocks 1 Antenna masquade 2 Antenna shield 3 Opening control for the connection of push button panel key...

Страница 10: ...t AP1 t AP2 etc will be appear press UP key to flow the chart from the bottom to the top press MENU key to flow the chart horizontally for example if the t ChP function is displayed by pressing the M...

Страница 11: ...Start off Si 8 St AP no ChiU PAUS Start in opening START command is not available command close the gate stop the gate and goes in Pause PAUS 9 St Ch Stop APEr Start in closing command START stop the...

Страница 12: ...he motion STOP command stops the gate START command starts moving in the opposite direction no 20 Fot 1 no APCh Input PHOTO 1 not available photocell active during the opening the closing no 21 Fot 2...

Отзывы: