background image

Installation instructions

Built-in variants of gas hob

Dials GAS641/731

1014402-10

26/07/2023

1014402-10

6

Minimum distances and installation conditions

The distance from the appliance cut-out to the back wall must be ≥50 mm and to the side walls ≥200 mm. Parts such
as side walls and reinforcing strips which protrude into the installation space under the cooking zone must be made
of fire-resistant material.
The distance between the underside of the appliance tray and any part of the cabinet beneath that is made of com-
bustible material must be ≥20 mm.

≥750

≥450

X

When a range hood is installed above the gas hob, the minimum distance given for
the particular range hood must be observed.
Furthermore, the minimum distances illustrated must be strictly complied with if a
lower value is stated for the range hood.

The worktop must be flat in order that it is sufficiently sealed against the ingress of
liquids.

In order to guarantee good ventilation, a space of at least 20 mm in height is ne-
cessary beneath the appliance.

If the hobs are used at an altitude of over 2,000 metres, a reduced performance
must be expected.

Model number

Type

X

31075

GAS731GKBZ

73.1

31089

GAS641GKAZ

46.7

Gas connection

The gas connection and the conversion to another gas type must be carried out by an authorized installer.

51

46

GAS641

51

46

22.4

G½ ISO 228/1

GAS731

65

The gas connection must be positioned so that the stop-cock and the supply connection point are accessible with the appliance in-
stalled.

The gas connection must be positioned so that it does not get detrimentally hot during operation. In particular, the gas hose assem-
blies and the appliance’s connection fittings must be clear of hot exhaust gases (e.g. from an oven).

It must be ensured that the gas hose and the mains connection do not touch any hot parts of the appliance, otherwise the gas hose
and the mains cable could become damaged through heat.

A flexible connection lead (max. length 1.5 m) must be positioned so that it runs freely and does not come into contact with any mov-
able parts of the kitchen cabinets (e.g. a drawer).

½-inch metric thread

The gas connection on the appliance has a ½-inch external thread in accordance with ISO 228/1. If the gas installation on site already
has a corresponding counterpart, the gas appliance can be directly connected to it.

It is imperative to use the sealing ring for the front-end seal!

Содержание GAS641

Страница 1: ...a combustible material the guidelines and standards for low voltage installations and fire protection must be strictly observed All leak tests should be done with a soapy water solution Never use an...

Страница 2: ...the surface mounted combination of several hobs 1019199 Flush installation Designation Article no Steel angle set hob size 60 H63772 Designation Art no Instant adhesive for installation of the steel a...

Страница 3: ...of the gas connection Ri Corner radii of appliance for base plate Ra Outer corner radii of cut out S Minimum distance between the top of the work surfaces and any drawer T Minimum distance between the...

Страница 4: ...Ra Outer corner radii of cut out S Minimum distance between the top of the work surfaces and any drawer T Minimum distance between the cut out in the back and any drawer Installation Create an accurat...

Страница 5: ...information on the required mains voltage current type and fuse protection The connection cable has either a plug or three stranded wires Plug in appliances must be connected to an easily accessible...

Страница 6: ...performance must be expected Model number Type X 31075 GAS731GKBZ 73 1 31089 GAS641GKAZ 46 7 Gas connection The gas connection and the conversion to another gas type must be carried out by an authoriz...

Страница 7: ...ed All the nozzles are numbered to avoid any mix up Always disconnect the appliance from the electricity and gas mains before changing the nozzles Changing the injector nozzles Remove the pan supports...

Страница 8: ...ains After the nozzles have been changed leak testing must be carried out and then the flame pattern checked in the min max position for each burner Nozzle table Change injector nozzles using a 7 inch...

Отзывы: