background image

Installation instructions

Built-in variants of gas hob

Dials GAS641/731

1014402-10

26/07/2023

1014402-10

3

Surface-mounted installation

The layout of the hob to be fitted may differ from the hob illustrated!

Y

Y

H

Y – Y

B

Drawer/
cabinet

Side panel

S*

 ≥81

T

 ≥90

Ri

Ra

600

560±1

490

±1

≥5

0

≥50

600

H

50

1

571

GAS641GKAZ (31089)

  ≥50

H

Y

Y

501

691

Ri

GAS731GKBZ (31075)

490±1

≥5

0

600

Ra

680±1

600

* The required clearance must be observed!

Type

B

H

Corner radius Ra/Ri

GAS641GKAZ, GAS731GKBZ

≥95 mm

84 mm

0–5/2 mm

B

Required clearance for service replacement

H

Dimension from the top of the work surface to the underside of the gas connection

Ri

Corner radii of appliance for base plate

Ra

Outer corner radii of cut-out

S

Minimum distance between the top of the work surfaces and any drawer

T

Minimum distance between the cut-out in the back and any drawer

Installation

Do not damage the sealing bead.
The sealing bead must lie all around the edge of worktop.

Create an accurate installation cut-out.

Carefully put the appliance in the installation cut-out and press against the worktop with sufficient overlap.

Fit the four adjusting braces along the circumference of the appliance to the bore holes provided and tension the appliance against
the worktop.

Combination installation

Surface-mounted combination installation is described in document 1013773. The intermediate support 1014361 or 1019199 is re-
quired for this.

Содержание GAS641

Страница 1: ...a combustible material the guidelines and standards for low voltage installations and fire protection must be strictly observed All leak tests should be done with a soapy water solution Never use an...

Страница 2: ...the surface mounted combination of several hobs 1019199 Flush installation Designation Article no Steel angle set hob size 60 H63772 Designation Art no Instant adhesive for installation of the steel a...

Страница 3: ...of the gas connection Ri Corner radii of appliance for base plate Ra Outer corner radii of cut out S Minimum distance between the top of the work surfaces and any drawer T Minimum distance between the...

Страница 4: ...Ra Outer corner radii of cut out S Minimum distance between the top of the work surfaces and any drawer T Minimum distance between the cut out in the back and any drawer Installation Create an accurat...

Страница 5: ...information on the required mains voltage current type and fuse protection The connection cable has either a plug or three stranded wires Plug in appliances must be connected to an easily accessible...

Страница 6: ...performance must be expected Model number Type X 31075 GAS731GKBZ 73 1 31089 GAS641GKAZ 46 7 Gas connection The gas connection and the conversion to another gas type must be carried out by an authoriz...

Страница 7: ...ed All the nozzles are numbered to avoid any mix up Always disconnect the appliance from the electricity and gas mains before changing the nozzles Changing the injector nozzles Remove the pan supports...

Страница 8: ...ains After the nozzles have been changed leak testing must be carried out and then the flame pattern checked in the min max position for each burner Nozzle table Change injector nozzles using a 7 inch...

Отзывы: