Installation instructions
Built-in variants of gas hob
Multi-sliders GAS411/421/641/951
1014422-R09
27/07/2017
1014422-R09
6
Minimum distances and installation conditions
The distance from the appliance cut-out to the back wall must be ≥50 mm and to the side walls ≥200 mm. Parts such
as side walls and reinforcing strips which protrude into the installation space under the cooking zone must be made
of fire-resistant material.
The distance between the underside of the appliance tray and any part of the cabinet beneath that is made of com-
bustible material must be ≥20 mm.
≥750
≥450
When a range hood is installed above the gas hob, the minimum distance given for
the particular range hood must be observed.
Furthermore, the minimum distances illustrated must be strictly complied with if a
lower value is stated for the range hood.
▪
The worktop must be flat in order that it is sufficiently sealed against the ingress of
liquids.
▪
In order to guarantee good ventilation, a space of at least 20 mm in height is ne-
cessary beneath the appliance.
▸
The appliances are designed for use up to a max. altitude of 2000 m above sea
level.
Gas connection
The gas connection and the conversion to another gas type must be carried out by an authorized installer.
67
187
67
187
67
125
69
330
GAS411
GAS421
GAS641
GAS951
32.5
G½ ISO 228/1
32.5
G½ ISO 228/1
65
65