Installation instructions
CTI4T64/74
CookTopInduction V4000
Glass ceramic hob
1065985-R01
23/04/2019
1065985-R01
9
Installation of the ventilation protective plate with 3 mm ventilation gap at the front
A protective plate is necessary for the adequate ventilation of the hob.
The distance between the underside of the appliance and the protective plate must be ≥10 mm.
393
(30)
≥
67.5
5..10
53.5
56
ø4
≥
15
(X)
H
≥
3
≤
0.5
2.5
Caution: Mains cable must
not touch protective plate!
Well-fitting seal over
width of cabinet element
Air gap over entire width of
cabinet element
≥
17 cm²
According to template
Drawer
Fan
Type
X
Remarks
CTI4T64MMSLC, CTI4T64MMSOLC, CTI4T74MMSLC, CTI4T74MMSOLC
12 mm
Normal mounting frame
CTI4T64MMSLD, CTI4T64MMSOLD, CTI4T74MMSLD, CTI4T74MMSOLD
12 mm
Surface-mounted installation
CTI4T64MMSLD, CTI4T64MMSOLD, CTI4T74MMSLD, CTI4T74MMSOLD
10 mm
Flush installation
CTI4T64MMSLU, CTI4T64MMSOLU
13 mm
With oversize mounting frame
H
Dimension from the top of the work surface to the underside of the hob (ventilation opening).
Cool air supply with regard to drawer or cabinet installed below
In order to guarantee good ventilation, a space of ≥ 10 mm height is necessary beneath the appliance.
≥5
≥15
(30)
550/600
825/900
H
B
Drawer
Centre of fan
≥25 cm²
Air gap over the entire cabinet element width
A
A
Necessary space below the worktop for the appliance.
B
Necessary space below the worktop for the ventilation of the appliance.
H
Dimension from the top of the work surface to the underside of the hob (ventilation opening)