background image

Installation instructions

CTI4T64/74
CookTopInduction V4000
Glass ceramic hob

1065985-R01

23/04/2019

1065985-R01

8

Variable areas of the special cut-out dimensions

CTI4T64MMSLU, CTI4T64MMSOLU

560–585

490–530

=

=

(30)

6 adjusting braces

Aim for
≤R10

Reinforcement of the cut-outs with 
a complete chrome-nickel steel cover

Arrangement of the adjusting braces

≤25

≤32

E

D

40

30

(≤ screw length)

(≤ screw length)

Warning, glass breakage:
Do not overtighten screws

Reinforcing slats:

≥25 × 25 mm

Plate for chrome-nickel steel cover

The installation instructions with regard to electrical and safety-related issues remain fully valid for this installation.

1.

Make a precise, right-angled cut-out in the work surface (if not already present). Aim to keep the cut-out dimensions to a minimum.

2.

Securely clamp the appliance in the cut-out using the enclosed adjusting braces 

D

 and screws 

E

. If necessary, install reinforcing

slats and use these to make the cover flat.

Содержание CookTopInduction V4000 CTI4T64 Series

Страница 1: ...size mounting frame 31115 CTI4T64MMSLC CTI4T64MMSOLC CTI4T64MMSLD CTI4T64MMSOLD CTI4T64MMSLU CTI4T64MMSOLU 31116 CTI4T74MMSLC CTI4T74MMSOLC CTI4T74MMSLD CTI4T74MMSOLD General notes If installing into...

Страница 2: ...niche width 900 mm H61085 Surface mounted installation Designation Art no Stainless steel intermediate support for the surface mounted combination of several hobs 1014361 Black intermediate support f...

Страница 3: ...e Check old installa tions If the hobs are used at an altitude of over 2 000 meters above sea level a reduced performance must be expected The appliance is equipped with a connection cable which must...

Страница 4: ...550 600 Ra CTI4T74MMSLC CTI4T74MMSOLC CTI4T64MMSLC CTI4T64MMSOLC Cable length 1 7 m Cable length 1 7 m The required clearance must be observed Cut out if niche width 550 mm Type A Depends on producer...

Страница 5: ...rance must be observed Type A Depends on producer B H Corner radius Ra Ri CTI4T64MMSLD CTI4T64MMSOLD CTI4T74MMSLD CTI4T74MMSOLD 20 mm 60 mm 50 mm 5 1 5 mm A Worktop depth in combination with directly...

Страница 6: ...uilt under oven does not apply to small appliances B Required clearance for ventilation and service replacement over the entire cut out area H Dimension from the top of the work surface to the undersi...

Страница 7: ...with directly built under oven does not apply to small appliances B Required clearance for ventilation and service replacement over the entire cut out area H Dimension from the top of the work surface...

Страница 8: ...30 screw length screw length Warning glass breakage Do not overtighten screws Reinforcing slats 25 25 mm Plate for chrome nickel steel cover The installation instructions with regard to electrical and...

Страница 9: ...TI4T74MMSOLC 12 mm Normal mounting frame CTI4T64MMSLD CTI4T64MMSOLD CTI4T74MMSLD CTI4T74MMSOLD 12 mm Surface mounted installation CTI4T64MMSLD CTI4T64MMSOLD CTI4T74MMSLD CTI4T74MMSOLD 10 mm Flush inst...

Отзывы: