Installation instructions
Heat pump dryer
One-family household
1068340-06
03/10/2022
1068340-06
7
Connecting the condensate drain
The drain hose for the tumble dryer must not be lengthened!
Otherwise water from the drain hose of the tumble dryer can flow into the condensate tank of the tumble dryer when the con-
densate pump is switched off.
Never connect the drain hose from a tumble dryer to the drain hose from a washing machine so that it is watertight
(hydraulically)!
Otherwise water from the drain hose of the washing machine can flow into the condensate tank of the tumble dryer!
Do not immerse the end of the drain hose from the tumble dryer in the water in the drain trap!
Otherwise water in the drain-trap bend can flow into the condensate tank when the condensate pump is switched off.
Single connections
▸
For connection to sink drain trap, use set
W53070
.
▸
For drainage into open-top fixed upright outflow pipe, use condensate
drain kit
W56298
. Use an open-top fixed upright outflow pipe with the
drain trap.
▸
Leave a gap of ≥5 cm between the end of the drain hose from the
tumble dryer and the level of the water in the drain trap.
▸
Position the drain hose from the tumble dryer above the overflow line
1
.
Do not exceed the maximum pumping height (≤1200)!
W56298
W53070
≥35
0
1
≤1200
Tumble dryer positioned next to washing machine: Separately routed drainage pipe
▸
Use an open-top fixed upright outflow pipe with the drain trap.
▸
Leave a gap of ≥5 cm between the end of the drain hose from the
tumble dryer and the level of the water in the drain trap.
▸
Insert the drain hoses from both appliances into the riser pipe of the
drain trap.
▸
Position the drain hose from the tumble dryer above the overflow line
1
.
Do not exceed the maximum pumping height (≤1200)!
Tumble dryer positioned next to washing machine: Combi drain kit
▸
Use an open-top fixed upright outflow pipe with the drain trap.
▸
Use condensate drain kit
W55969
.
▸
Leave a gap of ≥5 cm between the end of the drain hose from the
tumble dryer and the level of the water in the drain trap.
▸
Do not exceed the maximum pumping height (≤700)!
≤700
W55969