Installation instructions
Heat pump dryer
One-family household
J296.113-0
25.6.08 ITH
3
Free-standing position
Positioning in a niche
A
Centre the installation plate in the niche.
A
Roughly adjust the rear adjuster feet.
A
To ensure smooth, fault-free operation, the appliance must be perfectly vertical. Use a
spirit level to position the appliance.
A
Slide the appliance in. Finely adjust the front adjuster feet until all 4 feet are standing
firmly on the floor.
– The appliance must not wobble.
A
Information on the necessary mains voltage, type of current and fuse protection is to be obtained from the identification plate.
If a tumble dryer and a washing machine are positioned side by side, keep a distance of min. 5 mm between installation plates
and min. 3 mm to walls.
* This only applies if no plumbing fittings are to be installed behind the appliance.
Add another 20 mm if the condensed water hose leads away to the left.
2. Levelling
3. Electrical connections
Electrical connections must be carried out by trained electricians in accordance with the guidelines and standards for low volt-
age installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. A
mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and socket
devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching are per-
missible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and fault-
free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should al-
ways be checked.
min. 3
597
595
50
505
min. 550*
min. 5
min. 5
min. 600*
Niche depth
min. 600
Niche width
Cut-out for lateral
connections, to the
left or right side
min. 100 × 100 mm
Niche height
min. 860 mm!