![V-TUF VSC240V Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/v-tuf/vsc240v/vsc240v_operators-manual_3090132019.webp)
19
The boiler is producing
excessive amounts of fumes
Presence of water in the fuel
tank.
Empty the fuel tank, and refill with
clean fuel.
The fuel pump pressure is not
correct
Restore the correct pressure,
turning the appropriate screw in
order to reach approximately 10
Bar.
The starter electrodes are not
positioned correctly.
Check the distance of the
electrodes.
The fuel nozzle is dirty
Clean the fuel nozzle
The fuel nozzle is worn out
Replace the fuel nozzle
The boiler coil is blocked
Clean the boiler coil
The fuel pump is dirty
Clean the fuel pump
The fuel electrovalve is not
working.
Replace the fuel electrovalve.
The boiler switches itself off.
The fuel level is low.
Refill the fuel tank.
The filter on the fuel suction tube
is dirty.
Clean the fuel filter.
Presence of water in the fuel
tank.
Empty the fuel tank, and refill with
clean fuel.
The pressure switch is not
working.
Replace the pressure switch.
The starter transformer is broken.
Replace the starter transformer.
The starter electrodes are not
positioned correctly.
Reposition the starter electrodes
into the correct position.
The fuel nozzle is dirty.
Clean the fuel nozzle.
The fuel nozzle is worn out.
Replace the fuel nozzle.
The fuel pump is damaged.
Replace the fuel pump.
The fuel electrovalve is damaged.
Replace the fuel electrovalve.
Presence of water in the
pump oil
Worn out pump seals
Replace the oil seal.
High percentage of humidity on
the air.
Change the oil twice as often as is
normally prescribed.
Excessive noise
Air is being sucked in.
Dirty water filter
Insufficient water supply.
Check the seals in the tubing.
Clean the water filter.
Check that the machine has a
water supply superior to the flow
rate of the pump.
The springs on the suction and/or
delivery valves are worn out or
broken.
Replace the valves.
Foreign bodies in the suction
and/or delivery valves.
Check and clean the valves.
Worn out ball bearings.
Replace the ball bearings.
The temperature of the water
being pumped is excessive.
Lower the temperature of the
water being pumped.