![V-TUF VSC240V Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/v-tuf/vsc240v/vsc240v_operators-manual_3090132011.webp)
11
Attach the lance to the high-pressure hose (1) and the other end to the output connection (Water outlet).
Fit the sheath (B) in order to protect the hydraulic connection and to avoid the risk of scalding by contact.
The high pressure pump is supplied already full of lubricating oil. Attach a water tube (not supplied) to the
entry connection (Water inlet) and the other end to the tap of the water source (4) which must be able to
provide a minimum flow rate equal to that of the pump.
Check that the electric supply socket has the appropriate characteristics and differential protection, and
conforms to safety standards in force, then insert the plug into the power socket.
Wherever possible, avoid the use of extension cables with the electrical supply cable. If an electric
extension is required, please use the correct specification such as EXTENSION LEAD ' Motor Saver' - 30M
240VOLT 2.5mm (13AMP) - I10.1630
ATTENTION:
The electrical power supply should be provided by a magneto thermic switch adequate to the power of the
machine.
Also, there should always be installed a high sensitivity differential switch with a cut-off threshold of
Idn=0.030 A.
It is necessary that the machine is earthed in such a way as to guarantee a contact voltage of no more than
25V.
Operation of the machine should be carried out in such a way that damage cannot be caused to people or
property and, wherever possible, away from paths of transit.
In the United Kingdom, it is specified that an external socket (external to the building) must have an RCD.
This can be a ‘plug in’ IP rated 13amp RCD. If the External socket is 16amp than the RCD must be IP rated
and part of the socket.
RCD on internal sockets (which are part of the ring main electric supply), are normally on the main control
board and it is now specified that these are tested on the test button, at least every three months.
What is electric RCD?
An RCD, or residual current device, is a life-saving device which is designed to prevent you from getting a
fatal electric shock if you touch something live, such as a bare wire. ... RCDs offer a level of personal
protection that ordinary fuses and circuit-breakers cannot provide.
Fuel filler
Fuel filter
Pressure
Adjustment
Water inlet
Water outlet