background image

2 EASY

4) ID Module:

Parts and functions

Card Operation

Swiping card

area

LED indicator

Mounting 

screw

• 

Master Card Setting

Power on and short out EB+,EB- , a sound of “BP+” will be sent out, 
and the 

Unlock indicator

 is turned on.

Toggle DIP4 switch for four times, a sound  of “BP+,BP” will be sent 

out , the 

Talk  indicator

 and the 

Unlock indicator

 will be turned on.

Show the 

ADD CARD

, a sound of “BP+” will be sent out, the 

Unlock 

indicator

 is turned on.

Show the 

DELETE CARD

, a sound of “BP+” will be sent out, and all 

indicators will be turned off. After 10 seconds,it will exit out the 

Master 

Card Setting

 automatically. 

Power on and short out EB+,EB- , a sound of “BP+” will be sent out, 
and the 

Unlock indicator

 is turned on.

• 

User Card Setting

In standby mode, show the 

MASTER CARD ADD

, it will sound 

“BP+,BP”, the 

Talk indicator 

is turned on.

Input the room number you need to set (0 is default). Show 

User 

Cards

, it will sound “BP+”, and the 

Talk indicator

 blinks one time. 

(You can continuously show 

User Cards

).

Show the 

MASTER CARD ADD

 to exit out Add User Card Setting, 

it will sound “BP,BP+”, and all indicators are turned off. (without any 
operation for 10 seconds, it will return to standby mode)

In standby mode, show the 

MASTER CARD DELETE

, it will sound 

“BP+,BP”, and the 

Unlock indicator

 is turned on. and the 

Delete 

Card Mode

 is activated.

--

Delete by room number

: Input the room code, it will sound “BP+”, 

and the 

Unlock indicator

 blinks one time,all associated cards will be 

deleted..

--

Delete by User Card

: Show the 

User Cards

 which you need to 

delete. It will sound “BP+”, and he 

Unlock indicator

 blinks one time. 

(You can continuously show user cards that you need to delete)

In Delete Card Mode :

Show the 

MASTER CARD DELETE

 to exit out 

Delete Card Mode

It will sound “BP,BP+”, and all indicators are turned off. (without any 
operation for 10 seconds, it will return to standby mode)

i) Add User Card

ii) Delete User Card

In standby mode, show the 

MASTER CARD DELETE

, it will sound 

“BP+,BP”, and the 

Unlock indicator

 is turned on.

Show the 

MASTER CARD ADD

, it will sound “BP+,BP”, and the 

Talk 

indicator

 and the 

Unlock indicator

 are turned on.

Show the 

MASTER CARD ADD

, it will sound “BP”, the 

Talk indica-

tor

 and the 

Unlock indicator

 will blink, and after 10 seconds, it will 

return to standby mode and the format is finished.

iii) Format Card

DT System Test Manual

-11-

Содержание 2 easy DMR18S

Страница 1: ...2 wire Intercom System 2 EASY CONTENTS DT SYSTEM TEST MANUAL DMR18S DOOR STATION 2 DMR21 DOOR STATION 3 DT BDU BUS AMPLIFIER 12 1 2 3 6 5 4 7 8 9 0 RF CARD RF CARD...

Страница 2: ...t Cancel Save 2 Tone Select 01 00 Mute 01 Tune 02 English Cancel Save 0 3 0 5 Work Mode 0 Cancel Save 0 3 0 1 ID Code 0 Input Mode In standby mode Input 8001 Code 66666666 by default then select 5 ite...

Страница 3: ...he Doorplate Mode for example input 3 06 to call the monitor As the following picture shows 3 means the third BDU and 06 means the ID code of monitor is 06 Cancel Save 1 1 1 5 Doorplate Mode 11 0 1 12...

Страница 4: ...y Setting Attention All settings will be canceled if the Restore Factory Setting is activated Include the modules setting such as ID module Touch Keypad module etc Even if the modules are not connecte...

Страница 5: ...me list Press or to select name After that press to call the corresponding user Press Keypad Module to cancel the call Calling Display Conversation This is the user interface of calling process Know t...

Страница 6: ...You should press confirm button after finish input ting the code number each time otherwise the operation will be cancelled automatically in 10s Setting items Setting range Default value Setting code...

Страница 7: ...9 range 01 99 3 Setting the key illumination time 4 Setting the unlock time 2 Setting the master code Default 1234 Default 10s Default 1s Inputting of new master code ex 4321 1 12 digits Input the set...

Страница 8: ...u set last time When the operation tone is set to 0 pressing the digital keypad will sent out a sound of beep When the operation tone is set to 1 pressing the digital keypad will blink one time Cancel...

Страница 9: ...he CALL button Beep Beep Beep 11 SPK volume adjust setting Input the setting code Input the setting code 11 Inputting of code ex 5 range 0 9 5 Default 4 Unlock via password is still available even whe...

Страница 10: ...release the second lock the second lock need external device to support If the password length exceeds 12 digits the system will sent out the sound of beep beep beep beep and the digitals you input be...

Страница 11: ...nd BP BP and all indicators are turned off without any operation for 10 seconds it will return to standby mode In standby mode show the MASTER CARD DELETE it will sound BP BP and the Unlock indicator...

Страница 12: ...4 5 6 ON 1 2 3 4 5 6 ON Set to the Router mode Set to the Gateway mode Reserved Bit 3 Bit 5 1 2 3 4 5 6 ON Set to the third DT BDU Set to the second DT BDU 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON Set to the fo...

Страница 13: ...equal to the DT BDU num ber Wiring diagram Wiring diagram BUS IM BUS DS PC6 AC 1 2 3 6 5 4 7 8 9 0 OUT DS BDU IN IN BUS IM BUS DS PC6 AC OUT DS BDU IN IN BUS IM BUS DS PC6 AC DT BDU 1 2 3 6 5 4 7 8 9...

Отзывы: