V-TAC VT-8051 Скачать руководство пользователя страница 2

INSTALLATION

MANUAL OVERRIDE FUNCTION

1. To override the automatic mode, the sensor must be switched ON in the automatic mode. Now switch wall switch OFF-ON, 

OFF-ON twice within 3 seconds. The sensor will now hold your light ON continuously just likes a normal light.

2. To return your sensor to the automatic mode, switch your wall switch OFF, then switch ON after 0.3seconds.

3. If the light left ON (not change the sensor to AUTO mode by hand), the sensor itself will also automatically return to the automat-

ic mode after 8 hours.

 

 

 

Warning! 

Please make sure to turn off the power before starting the installation. Install only by certified Electrician. 

• Bevor Sie beginnen, schalten Sie den 

Strom aus!

• Installation nur von Elektrofachkräften

• WYŁĄCZYĆ zasilanie przed przystąpieniem 

do instalacji!

• Instalacja powinna być wykonywana 

wyłącznie przez elektrotechnika posiada

-

jącego certyfikat.dado!

• DESLIGAR a alimentação antes de iniciar

• A instalação só pode ser feita por 

electricista autorizado.
• ΚΛΕΙΣΤΕ την ηλεκτροδότηση προτού 

αρχίσετε!

• Τοποθέτση μόνο από αδειούχο 

ηλεκτρολόγο.

(DE) 

(PL)

(PT)

(EL)

• ISKLJUČITE struju prije nego što 

počnete ugradnju!

• Tijekom ugradnje morate osigurati 

odgovarajuće uzemljenje.
• DECONECTAŢI alimentarea cu energie 

electrică înainte să începeţi instalarea!

• Instalarea se va realiza numai de către un 

electrician autorizat. 

 

• COUPER l’électricité avant de commencer!

• Installation par électricien certifié
• KAPCSOLJA KI a villamos ellátást a 

kezdet előtt!

• Csak szakképzett villanyszerelő 

szerelheti fel.

(HR) 

(RO)

(FR)

(HU)

• ИЗКЛЮЧЕТЕ електричеството преди 

да започнете!

• Инсталация само от сертифициран 

електротехник
• IApague la electricidad antes de 

comenzar!

• Instalación solo por electricista 

certificado.
• Spegnere l'elettricità prima di iniziare!

• Installazione soltanto da parte di un 

elettricista certificato  

• VYPNĚTE elektřinu, než začnete!

• Instalaci smí provést pouze certifiko

-

vaný elektrikář

(BG) 

(ES)

(IT)

(CZ)

This marking indicates that this product should not 

be disposed of with other household wastes.

Caution, risk of electric shock.

• Unload the transparent vinyl cover which is at the bottom of the sensor.

• Loose the screws in the connection terminal, and then connect the power to connection terminal of sensor according 

to connection-wire diagram.

• Install back the transparent vinyl cover into the original location.

• Fold the metal spring of the sensor upwards, until they are in “I” position with sensor, and then put the sensor into the 

hole or installation box which is on the ceiling and has the similar size with the sensor. Releasing the spring, the sensor 

will be set in this installation position.

• After finishing installing, turn on the power and then test it

STEP 1

STEP 2

STEP 3

 

CONNECTION-WIRE DIAGRAM

SENSOR INFORMATION

TEST

Height of installation: 2.2-4m

Detection Distance: Max 6m

• Turn the TIME knob anti-clockwise on the minimum (10s).Turn the LUX knob clockwise on the maximum (sun).

• Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After Warm-up 30sec, the sensor 

can start work .If the sensor receives the induction signal, the lamp will turn on. While there is no another induction signal any 

more, the load should stop working within 10sec±3sec and the lamp would turn off. 

• Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX, the sensor would not work and the 

lamp stop working too. If the ambient light is less than 3LUX (darkness), the sensor would work. Under no induction signal condi-

tion, the sensor should stop working within 10sec±3sec.