PV Connection
Warning:
Note:
PV cable suggestion
Cross-section
4mm²
The hybrid inverter has two MPPT channels, can be connected with two strings of PV panels.
Please make sure below requirements are followed before connecting PV panels and strings to the
inverter:
The fatal high voltage may on the DC side, please comply with electric safety
when connecting.
Please make sure the correct polarity of the cable connected with inverter, other-
wise inverter could be damaged.
• The open-circuit voltage and short-circuit current of PV string should not exceed the reasonable
range of the inverters.
• The isolation resistance between PV string and ground should exceed 300 kΩ.
• The polarity of PV strings are correct.
• Use the DC plugs in the accessory.
• The lightning protector should be equipped between PV string and inverter.
• Disconnect all of the PV (DC) switch during wiring.
STEP 1
STEP 2
Positive Crimp Contact
Negative Crimp Contact
Note:
Note:
Please use PV connector crimper to pinch the point of the arrow.
You’ll hear click sound when the connector assembly is correct.