26
5.5.4.2 EPS enable
Interface
Description
When the Grid and PV are powered off, Enable the battery to
supply power to the load, default option is enable.
EPS ENABLE
1:DISABLE
2:ENABLE
5.5.4.3 Battery wake-up
Interface
Description
When the battery is low and the battery relay has been
disconnected, the inverter will send instructions to the battery
forcibly sucking relay by BMS, and the inverter will charge.
The default option is disabled. (Partial battery support)
If you want to use this feature, please consult the battery brand
supported by the dealer. Use it only when the batter
y
is too low.
WAKE-UP EN
1:DISABLE
2:ENABLE
5.5.4.4 REMOTE CTRL
Interface
Description
Remote control the inverter on or off. (Subsequent support…)
The default option is disabled.
REMOTE CTRL
1:DISABLE
2:ENABLE
5.5.4.5 START DELAY
Interface
Description
The input value ranges from 20 to 300, which varies with different
standards.
START-UP DELAY
INPUT:
60
UNIT:
SEC
5.5.4.6 PV INPUT MODE
Interface
Description
Setup of PV Input mode.
INDEPENDENT: The default Settings
PARALLEL: This feature is for test use only, not customer use.
CV: This feature is for test use only, no customer use.
The factory setting by default is Independent,When parallel input
is set to be stand-alone mode,PV power will be imbalanced.
INPUT MODE
1.INDEPENDENT
2.PARALLEL
3.CV