the lamp is running incorrectly, and the details
can be viewed from this sub-interface. After
viewing, you can press the "Clear" button to
clear the error record
total usage time
This time of use
temperature
Display the current temperature of the lamp
bead
Common error
messages
illustrate
MT board
connection
failed
The motor board is not responding. There is a problem with
the serial communication line connecting the display board
and the motor board, or there is a problem with the motor
board.
X axis reset
failed
There is a problem with the X-axis photoelectric switch, or
the X-axis motor or motor board
Y axis reset
failed
There is a problem with the Y-axis photoelectric switch, or
the Y-axis motor or motor board
X axis Hall error
X-axis Hall, or there is a problem with the motor board
Y axis Hall error
Y-axis Hall, or there is a problem with the motor board
Color wheel
reset failed
The color wheel Hall, or the color wheel motor has a
problem
Pattern disk
reset failed
Gobo Hall, or gobo motor is faulty
Focus reset
failed
Focusing Hall, or there is a problem with the focusing motor
11.Channel
17CH
CH
Function
CH Value
Effect
1
X
000-255
Horizontal 540 degree scan
2
X fine
000-255
Horizontal 1.2 degree fine-tuning
3
Y
000-255
Vertical 270 degree scan
4
Y fine
000-255
Vertical 1.2 degree fine-tuning
5
XY speed
000-255
Speed from fast to slow
6
Dimming
000-255
from dark to light
7
000-003
004-103
Shutter open
Strobe from slow to fast