Troubleshooting Guide
Monitor is set to Kilometres and needs changing to Miles
Remove one of the Monitor’s AA Batteries and wait for 30 seconds. Refit the Battery while
holding down the Reset Button and press again to set either M or K in the left corner of the
centre screen.
Feet are sliding out of the Footplates in use
The Footstraps (16) on your Air Rower can be set to two different positions.
Slide the Foot-straps out of the guides in the Footplates (15) and refit using the lower set of
holes in the Footplates. This will ensure that your ankles are pulled tightly into the Footplate
and will reduce the possibility of slipping in use.
There does not appear to be any “drive” to the Air Fan
The Drive Chain (31) has come off the Drive Gear Spindle (32) at the front of the Air Rower.
Remove the 2 x M5 x 12mm Machine Screws (39) that are securing the Drive Gear Cover (33)
and pull it towards you. Facing the Air Rower from the side with the Air Fan (27) on the left and
the Seat (8) on the right, with your LEFT hand, lift the Row Arm (24) vertically and with your
right hand underneath the Main Frame (1) pull the Drive Chain from right to left so that you can
carefully feed the Drive Chain back onto the Drive Gear Spindle at the front of the Air Rower.
When secured, slowly lower the Row Arm into its storage location at the top of the Exercise
Monitor Console (20).
The Stokes per Minute Counter does not work
First, check the above step regarding Drive to Fanwheel. If this does not work then check and
remake the connections between all of the Sensor Cables (21, 22, and 23). Fold the Rowing
Rail (2) over the top of the Main Frame (see Page 24 for Folding Instructions) and slightly
rotate the Seat Sensor (22) about its fitting screw and then move the Seat (8) up and down to
check if the Exercise Monitor (19) responds. Continue to move until the Monitor indicates a
Stroke Count or SPM figure.
The Speed Counter does not work
Unscrew the 6 (3 inside, 3 outside) x M4 x 63mm S/T Screws holding the Fan Covers (28) together.
Remove the Outer Fan Cover and the 4 x Air Fan Cover Inserts (29). Check to see if the Air Fan
Magnet is still in place in its location in a recess towards the centre of the Air Fan. If it is secure,
rotate the tip of the Air Fan Sensor Cable (23) about its fixing point until spinning the Air Fan (27)
causes the Exercise Monitor to register.
The Seat “bumps” when in use
Make sure that the lower part of the Rowing Rail (2) is always kept clean and dust / debris free as
dust will become compacted and as a consequence damage the Rail and the Seat Carriage Wheel
Assemblies (10). Clean the groove with a clean damp cloth and if necessary remove the complete
Seat Assembly and clean each Wheel before refitting.