Level limit switch
Series VN 1000 / 2000 / 5000 / 6000
Technical information / Instruction manual
page
Assembly VN ..040 with standard housing
2. Preparing the cables
Shorten the earth cable to
220 mm (8.66“) and sensor cables
to 150 mm (5.9“). Prepare cables
as shown.
3. Connecting the cables
Connect sensor cables to the
terminal connection piece. Fix the
cables with cable clamps. Connect
electronic module and terminal
connection piece. Be sure that all
terminals are tightly screwed in.
Take care that the non isolated
shield wire (M) does not touch
other metal parts (keep wire
short or isolate with a hose)
Connect the earth cable from the
vibrating fork to the housing (see
figure at the bottom of this page).
4. Fixing the electronic
module
Insert electronic module into
housing. The terminal connection
piece is used to guide the cables.
Fold connection cables as shown.
Use cylinder head screws to fix the
electronic module.
Connect the earth cable from the
electronic module to the housing
(not on all versions).
Earth cable (green-yellow)
Sensor cables
4= black (T)
3= shield (M)
2= red (R-)
1= white (R+)
Earth cable from
the electronic module
Earth cable from
vibrating fork
Terminal connection piece
Electronic module:
Flat side must
shown upwards!
Vibranivo
®
1
2
3
4
5
6
7
8
9
10
11
12
VN 1000 / 2000 / 5000 / 6000 g
gi180713
35