Level limit switch
Series RF 3000
Technical Information / Instruction manual
page
Mounting
Mounting: Rope version
Observe distance to
active probe
CORRECT
Long socket.
Use of inactive length.
CORRECT
Short socket.
Observe min. distance between two sensors and to
metal silo wall.
A
ct
iv
e p
ro
b
e
A
ct
iv
e p
ro
b
e
WRONG
Active probe
inside socket.
WRONG:
Active probe inside
intersection between
cylindric and conical part of
the silo (material may stay
when silo is empty)
Grounding reference
with non metal silos
The inner or outer PE terminal must be connected to reach a grounding reference.
Further mounting
requirements
• Observe distance to material flow (filling).
• Empty detector: Do not mount above the center of the silo outlet due to high traction force.
• Unit must be installed vertical.