page 28
Parameter adjustment
8.3.1 Main menu
This menu item enables you to adapt the sensor to the different
measuring conditions of the media " Liquid" or " Bulk solid". This
selection adapts the signal processing to the expected reflections.
This menu item enables you to optimally adapt the sensor to the
application, the place of use and the measuring conditions. The
adjustment possibilities depend on the selection made under "
Medium", " Liquid" or " Bulk solid".
The vessels as well as the measuring and process conditions are
described in the following as an overview.
With " Liquid", the applications are based on the following features,
to which the measuring characteristic of the sensor is adjusted in
particular:
Storage tank
•
Vessel:
–
Large volume
–
Upright cylindrical, horizontal round
•
Process/measurement conditions:
–
Slow filling and emptying
–
Smooth medium surface
–
Multiple reflections from dished vessel ceiling
–
Condensation
Stirrer vessel
•
Vessel:
–
Large agitator blades of metal
–
Installations like flow breakers, heating spirals
–
Nozzle
•
Process/measurement conditions:
–
Frequent, fast to slow filling and emptying
Medium
Application
Application - liquid