Operations Manual UWEX
®
722 C
19
_________________________________________________________________________
___________________________________________________________________
© 2005, Ebinger Prüf- und Ortungstechnik GmbH.
Pic.
7
Delay adjuster version
until serial no 436
Turn upper trimmer marked 'Z' (approx. 3 - 4 turns) in clockwise direction
to increase
the
delay, which reduces interference signals from saltwater and scrap metal.
Now recalibrate detector sensitivity to audio threshold (lower trimmer marked 'Tone).
To increase detector sensitivity to small metal objects turn adjuster anti-clockwise to
lower delay values.
Detectors with serial no.> 436 have a double micro switch
Pic.
8
: Delay switch version
from serial no. <436
New detector version (ser.no.>436) with micro switch for DELAY
The new detector version has a double micro switch in the battery compartment which
replace the previous trimmer for selecting preset delay values. The setting for land use is
also recommended for use in fresh / sweet water.