background image

21

IV  Appendix

IV UWATEC

®

 Aladin

®

 

ONE

IV

WARNING

WARNING

WARNING

1  Technical information  

Operating altitude: 

with decompression information: sea level up to approx. 4000 m (13120 ft);

 

w/o decompression, automatic gauge mode (at any altitude)

Max. displayed depth: 

120 m  (395 ft), resolution between 0.8 m and 99.9 m: 0.1 m, >99.9 m: 1 m

 

The resolution in feet is always 1 foot.

• Do not dive deeper than the limits given by the chosen fraction of oxygen 

(nitrogen narcosis, oxygen toxicity).

•  Never dive deeper than your training qualification (experience) allows you.
• Always observe local dive depth restrictions.

Decompression calculation depth range:

  0.8 to 120 m (3 to 395 ft)

Maximum environment pressure: 

13 bar (189 psi)

Clock:

 

Quartz clock, time, date, dive time display up to 199 minutes. 

O

2

% Mix:

 

Adjustable between 21%O

2

 (compressed air) and 50% O

Operating temperature:

  -10° to +50°C (14°F to 122°F).

Power supply:

 

CR2450, recommended brands: PANASONIC, DURACELL, RENATA, ENERGIZER, 
SONY, VARTA.

Life of the battery:

 

2-3 years or 200-300 dives. Actual life of the battery depends on the quantity 
of dives per year and the length of the dives. In cold water the life of the bat-
tery is reduced. Not all CR2450 batteries are the same, and low quality batteries 
can have very short life.

2  Maintenance

Aladin

®

 

ONE

 is virtually maintenance free. All you need to do is to rinse it carefully with fresh water after 

each use and to have the batteries changed when needed ->21. To avoid possible problems with your 
Aladin

® 

ONE

, the following recommendations will help assure that it will give you years of trouble free service:

• Avoid dropping or jarring your Aladin

® 

ONE

• Do not allow your Aladin

®

 

ONE

 to be exposed to direct, intense sunlight.

• Rinse your Aladin

®

 

ONE

 thoroughly with fresh water after each dive.

•  Do not store your Aladin

®

 

ONE

 in a sealed container; make sure there is free ventilation.

• If  there  are  problems  with  the  water  contacts,  use  soapy  water  to  clean 

Aladin

®

 

ONE

 and dry it thoroughly. The surface of your Aladin

®

 

ONE

 housing can 

be treated with silicone grease. Do not apply grease to the water contacts!

• Do not clean Aladin

®

 

ONE

 with liquids containing solvent (apart from water).

• If the battery icon appears, replace the battery ->21.
• Diving with a weak battery: Aladin

®

 

ONE

 may stop working during the dive, 

service icon and error code "E3" or "E6" appear. Close the dive and replace 
the battery ->21. 

•  On the surface: if service icon and error code "E3" appear, replace the battery ->21.
  All  error  codes  other  than  E3:  Aladin

®

 

ONE

  must  not  be  used  for  any  further 

dives. Take your dive computer to an authorized SCUBAPRO UWATEC dealer. 

2.1 Replacing the battery (Battery kit 06.201.919 includes battery and Teflon coated o-ring)

Removing the battery clears all physiological data including saturation. This 
means  that  for  a  repetitive  dive  the  computer  will  not  compute  correctly. 
Diving after replacing the battery when there is desaturation time left on the 
computer can lead to serious injury or death from decompression sickness. 
Change the battery only under these conditions:

•  After  a  dive  if  you  know  you  will  not  be  diving,  flying  or  going  to  higher 

altitude for the next 48 hours.

•  Before a dive if there is no desaturation left on the computer.

The  change  must  be  made  with  particular  care  in  order  to  prevent  water 
from seeping in. The warranty does not cover damages due to an improper 
replacement of the battery.

English

Содержание Aladin ONE

Страница 1: ...Operating Manual h s i l g n E SWISS MADE BY UWATEC AG ONE ...

Страница 2: ...d risk which are marked with a warning sign in this operating manual Aladin ONE has a ppO2 warning The limit is set at 1 4 bar ppO2max Frequently check the oxygen clock CNS O2 Ascend and finish the dive if the CNS O2 exceeds 75 Never dive deeper than the Maximum Operating Depth MOD pertinent to the gas mixture in use Always check the diving limits considering the oxygen content and standard sports...

Страница 3: ...xture to the intended dive Do not attempt a repetitive dive if the microbubble warning NO is visible on the display Plan a day without diving once a week If you have to change computers wait at least 48 hours before carrying out your next dive Diving after a reset of the remaining saturation reset see page 12 or battery replacement see page 21 may lead you into potentially hazardous situations whi...

Страница 4: ... provide divers with data they however do not provide the knowledge how this data should be understood and applied Dive computers cannot replace common sense You must therefore carefully read and understand this entire manual before using your Aladin ONE Indicates a potentially hazardous situation which if not avoided could result in death or serious injury WARNING Quick reference Current depth Lo...

Страница 5: ...___________________________11 3 2 Preparation for the dive and function check __________________________________12 3 3 Overview Aladin ONE settings __________________________________12 4 Functions during the dive __________________________________13 4 1 Immersion __________________________________13 4 2 Phosphorescent display __________________________________13 4 3 Dive time _____________________...

Страница 6: ...ure Aladin ONE SmartTRAK software CD is included with the Aladin ONE Package Infrared interfaces are available in PC stores A list of recommended interfaces is available on the UWATEC homepage www uwatec com 2 Operation 2 1 Water contacts On submerging in water the water contacts switch on Aladin ONE automati cally On the surface you can switch on the Aladin ONE by bridging the water contacts with...

Страница 7: ...e then select Dive Computer Settings under OPTIONS on the main menu bar If Aladin ONE detects an infrared device within range appears The following settings may be changed with SmartTRAK Range 21 50 O2 no reset 1 48 hrs metric imperial on off 13 hrs increments 15 min hours minutes 1 low 12 high Default 21 O2 no reset no reset GMT 4 Page 11 12 8 Number of past dives Total duration of dives Deepest ...

Страница 8: ...in altitude range is detected Aladin ONE switches on for 3 minutes automatically 20 2 4 Switching off the display On the surface Aladin ONE switches off automatically after 3 minutes without operation STOP S L O W NO DECO CNS O2 DEPTH NO STOP DIVE TIME DESAT AMPM STOP Time of day display 2 5 Battery warning and battery alarm When the computer senses that the battery needs to be replaced the steady...

Страница 9: ...depth reached during the dive Temperature No stop time Remaining time at a given depth during which ascent is allowed without decompression stop min Nitrogen loading bar Oxygen toxicity CNS O2 Dive time Duration of the dive min CNS O2 DEPTH NO STOP DIVE TIME Total ascent time to surface 7 min 6 m 35 7 m Decompression range No stop range 3 m Time Depth Decompression stop depth Deepest stage is disp...

Страница 10: ...ch ppO2 max is reached is called Maximum Operating Depth MOD When you enter the settings for the gas mixture with SmartTRAK SmartTRAK will display the corresponding MOD Aladin ONE warns the diver visually once the depth is reached at which the ppO2 reaches the maximum allowed value 15 The setting of ppO2 max is 1 4 bar CNS O2 Oxygen toxicity With the increased percentage of oxygen the oxygen in th...

Страница 11: ...arms given by Aladin ONE 3 Preparation for the dive Aladin ONE is set to 21 oxygen air from the factory If you wish to change this or any other setting you need to do so using the SmartTRAK software and the infrared interface Chapter III describes the most common settings On the next page you will find an overview with all possible Aladin ONE settings and page references 3 1 Setting the gas mixtur...

Страница 12: ...e dive and function check Check the display Switch on Aladin ONE by bridging the water contacts and check the test dis play Are all elements of the display activated Do not use Aladin ONE if the display does not show all elements Check the displayed O2 mix It is absolutely necessary to check the set mixture before each dive and to compare it to the gas mixture currently used Always remember settin...

Страница 13: ... 3 feet within 5 minutes While the dive time is running the colons on the right of the figures are flash ing in one second intervals Maximum dive time displayed is 199 minutes If a dive lasts longer than 199 minutes the dive time display starts again at 0 minutes 4 4 Current depth O2 mix Current depth is given in 10 cm increments 1 foot At a diving depth of less than 0 8 m 3 ft the display shows T...

Страница 14: ...ONE may require a decompression stop even within the no stop phase because of the danger of microbubble formation The decompression duration necessary for the prevention of microbubbles can increase massively if the ascent rate is exceeded From great depth a slow ascent may cause heightened saturation of tissues and an extension of both decompression duration and total ascent time At shallow depth...

Страница 15: ...e display changes back to the indication of the CNS value Aladin ONE will display CNS O2 values exceeding 199 with 199 CNS O2 DEPTH NO STOP DIVE TIME CNS O2 DEPTH NO STOP DIVE TIME CNS O2 DEPTH NO STOP DIVE TIME WARNING WARNING Oxygen toxicity Max Operating Depth MOD 4 7 Partial pressure of oxygen ppO2 max Maximum Operating Depth MOD The maximum partial pressure of oxygen ppO2 max 1 4 bar determin...

Страница 16: ...that require decompression stops are not recommended 16 4 Functions during the dive III UWATEC Aladin ONE DEPTH NO STOP DIVE TIME CNS O2 No stop time Nitrogen loading bar No stop time less than 1 minute WARNING WARNING CNS O2 DEPTH NO STOP DIVE TIME Decompression values On entering the decompression phase NO STOP disappears and the STOP DECO symbol appears The nitrogen loading bar stops flashing a...

Страница 17: ...scent rate is not ideal 100 Ascent time greater than 99 minutes is displayed as On all dives with Aladin ONE make a safety stop for at least three minutes at a depth of 5 m 15 feet STOP DECO CNS O2 DEPTH DIVE TIME STOP NO DECO CNS O2 DEPTH DIVE TIME Total ascent time Ignored decompression alarm WARNING WARNING 5 Functions at the surface 5 1 End of a dive After reaching the surface 0 8 m 3 ft Aladi...

Страница 18: ...ents in the residual nitrogen bar graph will gradually turn off as Aladin ONE follows the offgassing of your tissues during your surface interval There is a 1 1 equivalence in the meaning of the segments between diving and surface Thus on a repetitive dive the bar will resume from its status on the surface just prior to the dive There are two exceptions however the uppermost segment will stay lit ...

Страница 19: ... decompression stops The dive will be entered in the logbook with SOS Serious injury or death may result if a diver does not seek immediate treatment should any signs or symptoms of decompression sickness occur after a dive Do not dive to treat symptoms of decompression sickness Diving in SOS mode is extremely dangerous and you must assume full responsibility for such behaviour UWATEC will assume ...

Страница 20: ...titude ranges Aladin ONE measures the atmospheric pressure every 60 seconds even while the display is switched off If the computer detects a sufficient increase in altitude it switches on automatically and indicates the alti tude symbol the adaption time desaturation time as a bar graph and the time interval since the change in altitude class Desaturation time refers to adaptation time at this alt...

Страница 21: ... or jarring your Aladin ONE Do not allow your Aladin ONE to be exposed to direct intense sunlight Rinse your Aladin ONE thoroughly with fresh water after each dive Do not store your Aladin ONE in a sealed container make sure there is free ventilation If there are problems with the water contacts use soapy water to clean Aladin ONE and dry it thoroughly The surface of your Aladin ONE housing can be...

Страница 22: ...ng is in perfect condition and that o ring o ring groove and the sealing surfaces are free of dust and dirt If necessary clean the parts with a soft cloth Fit the o ring in the o ring groove of the battery cap 7 Use only an original UWATEC o ring PN 06 201 610 This o ring is Teflon coated and does not require additional lubrication 8 Do not lubricate the o ring as the lubricant will chemically att...

Страница 23: ...___________________ 10 11 15 Operating Aladin ONE _________________4 6 8 PC transfer to PC logbook _____________ 6 18 Phosphorescent display____________________ 13 ppO2 see O2 partial pressure Reset to air ____________________________ 7 12 Residual Nitrogen bar graph _______________ 18 SmartTRAK ___________________ 6 7 10 12 18 SOS mode_______________________________ 19 Surface interval __________...

Страница 24: ...scubapro uwatec it SCUBAPRO UWATEC Japan 4 2 Marina Plaza 5F Kanazawa Ku Yokohama Japan t 81 45 775 2288 f 81 45 775 4420 www scubapro co jp SCUBAPRO UWATEC France Les Terriers Nord 175 Allée Belle Vue F 06600 Antibes t 33 0 4 92 91 30 30 f 33 0 4 92 91 30 31 www scubapro uwatec fr SCUBAPRO UWATEC Benelux Avenue des Arts 10 11 Bte 13 1210 Bruxelles t 32 0 2 250 37 10 f 32 0 2 250 37 11 www scubapr...

Отзывы: