UVP BioDoc-It Скачать руководство пользователя страница 18

BioDoc-It and VisiDoc-It Imaging Systems 

 

18 

Warranty 

 

UVP's products are guaranteed to be free of defects in materials, workmanship and manufacture for one (1) 
year from date of purchase. Consumable and disposable parts including, but not limited to tubes and filters, are 
guaranteed to be free from defects in manufacture and materials for ninety (90) days from date of purchase. 
Transilluminators carry a two (2) year warranty from date of purchase. If equipment failure or malfunction 
occurs during the warranty period, UVP shall examine the inoperative equipment and have the option of 
repairing or replacing any part(s) which, in the judgment of UVP, were originally defective or became so under 
conditions of normal usage and service. 

No warranty shall apply to this instrument, or part thereof, that has been subject to accident, negligence, 
alteration, abuse or misuse by the end-user. Moreover, UVP makes no warranties whatsoever with respect to 
parts not supplied by UVP or that have been installed, used and/or serviced other than in strict compliance with 
instructions appearing in this manual.  

In no event shall UVP be responsible to the end-user for any incidental or consequential damages, whether 
foreseeable or not, including but not limited to property damage, inability to use equipment, lost business, 
lost profits, or inconvenience arising out of or connected with the use of instruments produced by UVP. Nor 
is UVP liable or responsible for any personal injuries occurring as a result of the use, installation and/or 
servicing of equipment. 
 
This warranty does not supersede any statutory rights that may be available in certain countries. 

 

 

 

 

VisiDoc-It and BioDoc-It are trademarks of UVP, LLC. Doc-It is a registered trademark of UVP, LLC.

 

Содержание BioDoc-It

Страница 1: ...Products Ltd 2066 W 11th Street Unit 1 Trinity Hall Farm Estate Upland CA 91786 Nuffield Road Cambridge CB4 1TG UK Phone 800 452 6788 909 946 3197 Phone 44 0 1223 420022 Fax 909 946 3597 Fax 44 0 1223...

Страница 2: ...transilluminator in the lab Configurations include a compact hood or camera stand The compact hood fits on top of UVP s High Performance and Benchtop Transilluminators The VisiDoc It System is simila...

Страница 3: ...efer to the packing slip and pictured components for parts included with the system VisiDoc It with Hood Transilluminator check the packing slip to determine if the system includes a transilluminator...

Страница 4: ...ransilluminator with UV Blocking Cover check the packing slip to determine if the system includes a transilluminator FluorCam 210 Camera with Lens Kit EtBr Filter is Mounted under the Lens 8 LCD Touch...

Страница 5: ...front 4 in the back USB storage device capacity 1GB minimum Software TS software Ethidium Bromide Filter EtBr The Ethidium Bromide EtBr Filter 50mm sq UV blocking band pass interference filter blocks...

Страница 6: ...hs and high low intensities or the high end FirstLight transilluminator Note For UV protection there is a 10 minute timer installed in the BioDoc It system The timer shuts off the transilluminator aft...

Страница 7: ...aviolet transilluminator The converter plate is specially coated to convert the 302nm UV output to white light rather than using a separate white light box The Visi Blue Converter Plate converts UV to...

Страница 8: ...m is turned OFF during cleaning Keep the equipment away from motors or other large magnetic equipment apparatus Installing the Filter Systems include a 50mm sq EtBr filter The filter is pre installed...

Страница 9: ...nly fit one way Using the four thumb screws provided secure the bracket to the base Slide the camera and lens assembly into the camera bracket Slide the lens through the center hole in the gasket The...

Страница 10: ...her end into a UBS port on back of the darkroom Connect the jumper cord from the darkroom to the transilluminator Connect the main power cord from the back of the darkroom to a surge protector power o...

Страница 11: ...diopter will only fit one way Using the four thumb screws provided secure the bracket to the base Slide the camera and lens assembly into the camera bracket Slide the lens through the center hole in...

Страница 12: ...nect the power cord from the transilluminator to a surge protector power outlet Connect the main power cord from the back of the processor to a surge protector power outlet Printer Set up The thermal...

Страница 13: ...er Using the System Powering Up the System In the BioDoc It Power up the system by pushing once on the MAIN POWER button located on the right side of the unit All internal components will now have pow...

Страница 14: ...desired angle Turn each knob clockwise to tighten Operating the TS Software The system will go through the boot up process When ready the LCD will display the TS software screen similar to the one be...

Страница 15: ...any exposure to UV Using the Gel Viewing Window in the BioDoc It The Gel Viewer has a pressure sensitive clasp Press firmly to open the viewer The glass is UV blocking while providing a clear view to...

Страница 16: ...01 Fluorescent Standard Step Tablet 33 0014 02 Doc It LS Analysis Software 97 0185 02 Spectacles UV Blocking UVC 303 98 0002 01 Goggles UV Blocking UVC 503 98 0002 02 Faceshield UV Blocking UVC 803 9...

Страница 17: ...r copy of Windows please contact your system administrator for assistance If an error message appears repetitively and your system administrator does not recognize it as a Microsoft Windows error cont...

Страница 18: ...rument or part thereof that has been subject to accident negligence alteration abuse or misuse by the end user Moreover UVP makes no warranties whatsoever with respect to parts not supplied by UVP or...