17
You can configure this parameter to adjust the result of voltage measurement.
The default value is set to 0.20V, and you can input a value between -1.27 and 1.27 here.
Vout adjustment
You can configure this parameter to adjust the result of output voltage measurement.
The default value is set to 0.20V, and you can input a value between -1.27 and 1.27 here.
Iout adjustment
The output current is calculated by measuring the voltage drop on the 0.05 Ohm sampling
resistor. You can configure this parameter to adjust the result of output current calculation.
The default value is set to 0.00A, and you can input a value between -1.27 and 1.27 here.
10.
Reset Data…
If you want to erase some data you previously set (scheduled startup time, scheduled shutdown time,
currently used schedule script, low voltage threshold, recovery voltage threshold), you can choose
this option.
Once you select this option, the software will display a sub menu, which allows you to:
Clear auto startup time:
The auto-startup time will be erased and Witty Pi 3 will not auto-start your Raspberry Pi.
Clear auto shutdown time:
The auto-shutdown time will be erased and Witty Pi 3 will not auto-shutdown your Raspberry
Pi.
Stop using schedule script:
The “schedule.wpi” file will be deleted.
Clear low voltage threshold:
The low voltage threshold will be unset.
Clear recovery voltage threshold
The recovery voltage threshold will be unset.
Perform all actions above:
Clear all scheduled times, remove the “schedule.wpi” file and unset the low voltage and
recovery voltage thresholds.
11.
Exit
Selecting this option will simply exit the software and return to the console.