Page 7
UTS SALES & REPAIRS LTD
LOCKING CASTORS
Castor wheels should be pointed outwards at approximately 45
degrees and locks engaged as shown opposite.
FITTING STABILISERS
Attach a stabiliser to each corner of the tower at approximately
45 degrees for maximum stability (refer to relevant illustrations)
and attach the clamps where indicated.
On the S3 stabiliser use the telescopic leg for adjustment on
uneven ground.
Make sure that all stabilisers are firmly in contact with the ground
when using the structure.
CORRECT FITTING OF
HORIZONTAL BRACING
THE CORRECT FITTING OF HORIZONTAL
BRACING IS IMPORTANT.
The diagrams opposite illustrate the CORRECT
brace positions.
REMEMBER: Always fit braces DOWNWARD
or from the inside facing OUTWARD –
BUT
NEVER INWARD
FITTING ADJUSTABLE LEGS
Take the adjustable leg assembly complete with its
castors, make sure that all the adjusting nuts are
positioned down at the castor and slide them into the
vertical tube, turn the base unit the right way up and with
the aid of a spirit level placed on the platform, the
adjusting nuts can be used to level the structure. (and not
to gain additional height).
BRACE CLAMP LOCKING
Ensure that the brace clamp is locked as shown.
Always make sure the brace is not clamped too close to the weld
as indicated by the arrow on the drawing on the right.
Un
-
Locked Locked
AGR CLAMP LOCKING
Hook over AGR clamp
Unscrew palm wheel
Then rotate bottom block into locked position.
Retighten palm wheel.
ALWAYS ENSURE BOTH BOTTOM AGR
CLAMPS ARE LOCKED BEFORE CLIMBING
UP TOWER TO LOCK TOP AGR CLAMPS.