UTS UTS 700 ONEMAN Скачать руководство пользователя страница 7

Page 7

 

UTS SALES & REPAIRS LTD

 

LOCKING CASTORS

 

Castor wheels should be pointed outwards at approximately 45 
degrees and locks engaged as shown opposite.

 

FITTING STABILISERS

 

Attach a stabiliser to each corner of the tower at approximately 
45 degrees for maximum stability (refer to relevant illustrations) 
and attach the clamps where indicated.

 

On the S3 stabiliser use the telescopic leg for adjustment on 
uneven ground.

 

Make sure that all stabilisers are firmly in contact with the ground 
when using the structure.

 

CORRECT FITTING OF 
HORIZONTAL BRACING

 

THE CORRECT FITTING OF HORIZONTAL 
BRACING IS IMPORTANT.

 

The diagrams opposite illustrate the CORRECT 
brace positions.

 

REMEMBER: Always fit braces DOWNWARD 
or from the inside facing OUTWARD –

 

BUT 

NEVER INWARD

 

FITTING ADJUSTABLE LEGS

 

Take the adjustable leg assembly complete with its 
castors, make sure that all the adjusting nuts are 
positioned down at the castor and slide them into the 
vertical tube, turn the base unit the right way up and with 
the aid of a spirit level placed on the platform, the 
adjusting nuts can be used to level the structure. (and not 
to gain additional height).

 

BRACE CLAMP LOCKING

 

Ensure that the brace clamp is locked as shown. 

 

Always make sure the brace is not clamped too close to the weld 
as indicated by the arrow on the drawing on the right.

 

Un

-

Locked    Locked

 

AGR CLAMP LOCKING

 

Hook over AGR clamp

 

Unscrew palm wheel

 

Then rotate bottom block into locked position.

 

Retighten palm wheel.

 

ALWAYS ENSURE BOTH BOTTOM AGR 
CLAMPS ARE LOCKED BEFORE CLIMBING 
UP TOWER TO LOCK TOP AGR CLAMPS.

 

 Un

-

Locked                            Locked

 

Содержание UTS 700 ONEMAN

Страница 1: ...ssembly Personnel should be qualified or competent to erect this tower Please consult the PASMA s code of practice for full information on the use of Mobile Access Towers Remember to do a risk assessm...

Страница 2: ...UTS 700 ONEMAN INSTRUCTION MANUAL Page 2...

Страница 3: ...nce 6 Components and Weights 8 Assembly 9 Dismantling 17 Configurations and Weights 18 Risk Assessment Form 19 UTS 700 ONEMAN Instruction Manual Mobile Access Tower UTS SALES REPAIRS LTD UNIT 1A CANTE...

Страница 4: ...efore assembly or erection of this Mobile Access Tower MAT please ensure that A risk assessment has been done and all safety equipment is on site The ground conditions will take the working loads of M...

Страница 5: ...and only from the base Beware of overhead obstructions live wires hanging apparatus or other objects Do not move with people or material on the tower Do not move the assembled MAT if wind speeds exce...

Страница 6: ...ded as a complete structure Always keep this instruction manual safe Broken damaged or incorrect components must never be used The equipment shall be quarantined and assessed for replacement repair or...

Страница 7: ...braces DOWNWARD or from the inside facing OUTWARD BUT NEVER INWARD FITTING ADJUSTABLE LEGS Take the adjustable leg assembly complete with its castors make sure that all the adjusting nuts are positio...

Страница 8: ...em Description Weight Kg 1 150mm Locking Caster 3 4 6 1 3m OMT Brace 6 2 Adjustable Leg 500mm 1 1 7 Complete Toe Board Set 6 3 1m 4 Rung Frame 5 6 8 OMT Hanging Bracket 1 4 1 3m Trapdoor Platform 9 1...

Страница 9: ...e never the outside When working on the platform never overreach The end frames should provide a firm hand hold Insert adjustable leg assembly with castors or base plates into the base of a rung end f...

Страница 10: ...sure bottom clamps are locked refer to page 7 Insert 4 rung sides onto each end of the tower ensure they clip in refer to page 6 Fit OMT Brace to 6th and 8th rungs of towers ensure bottom clamps are l...

Страница 11: ...S SALES REPAIRS LTD Fit a trap door platform to 4th rung of the tower engage the wind locks If completing at 1 2m fit toe boards to the working platform see instructions on page 4 5 If not continue to...

Страница 12: ...ng frames together using the clips then climb the tower on the inside using the rungs of the end frames Fit these double 4 rung ends to each end of the tower as shown Fit a OMT Brace to the 9th and 11...

Страница 13: ...2th rung lock wind locks From a seated position within the trap door of the platform fit a OMT Braces to the 14th and 16th rungs of the tower then ensure the bottom clamps are locked Fit toe boards to...

Страница 14: ...er using the clips then climb the tower on the inside using the rungs of the end frames Insert these onto each end of the tower ensure they clip in refer to page 6 Fit a OMT Brace to the 5th and 7th r...

Страница 15: ...d From a seated position within the trap door of the platform fit a OMT Braces to the 14th and 16th rungs of the tower then ensure the bottom clamps are locked If completing at 2 2m fit toe boards to...

Страница 16: ...hown Add a platform on the 16th rung lock wind locks Fit a OMT Brace to the 13th and 15th rungs of the tower the hang an assembly bracket from it to all the easy moving of components to higher levels...

Страница 17: ...tower at approx 45 degrees The bottom clamp should be fitted as low as possible refer to the diagram opposite Ensure that all four rubber feet are in contact with the ground and that the clamps are s...

Страница 18: ...g 500mm 4 4 4 4 1m 4 Rung Frame 4 6 8 10 1 3m Trapdoor Platform 1 1 2 1 3m Horizontal Brace 1 1 1 3m OMT Brace 3 4 Complete Toe Board Set 1 1 OMT Assembly Tool 0 1 Instruction Manual 1 1 S3 Stabiliser...

Страница 19: ......

Страница 20: ...20 UTS SALES REPAIR LTD UNIT 1A CANTERBURY INDUSTRIAL PARK ISLAND ROAD HERSDEN CANTERBURY KENT CT3 4HQ TEL 01227 860085 WWW TOWERSANDPODIUMS CO UK Notes DOC NO OM001 VERSION 1 1 DATE 01 01 21 APPROVE...

Отзывы: