NX-535N Voice Module Installation Manual
15
Connection diagram vs control panel
Connect the voice module NX-535N to the bus of the control panel. This can be
done by using the screw terminal or the 4 wired bus cable.
A special audio cable (included with the NX-535N) needs to be stuffed between
the control panel and the voice module NX-535N. If an NX-534E (listen-in) is
used in the system, also this should be connected by means of this cable.
Connect 1 lead of the audio cable between the “Audio tap” connector on the
control panel (connect white wire on the audio tap PIN 1 of the control panel –
see note below) and the connector on the NX-535N.
Connect the other lead to the “Audio tap” on the NX-534E if applicable (connect
the white wire towards the border side of the PCB).
Note:
For the correct pin layout of the Audio Tap on the control panel, check the
corresponding installation manual. Improper connections will cause the dialer of
the control panel or the NX-535N to malfunction.