background image

5

•DRAWINGS FOR ILLUSTRATION PURPOSES ONLY•

Your Ashley Furnace is designed to be a

supplemental or central heating source for your
home. This solid fuel furnace may be installed in
conjunction with a properly operating central fur-
nace that is listed or certified in accordance with
nationally recognized safety standards and
equipped with the required controls and other
safety features and which has been installed with
appropriate standards of  National Fire Protection
Association with  installation clearances specified
in the furnace nameplate marking. The installation
must be   accomplished by a qualified agency (one
who is engaged in, and is responsible for, or is
thoroughly familiar with the installation and   opera-
tion of the gas, oil, and solid fuel burning heating
appliances, who is experienced in such work,
familiar with all precautions required, and has
complied with all the requirements of the authority
having jurisdiction.) The installation shall be in
strict accordance with the manufacturer's installa-
tion instructions furnished with the solid fuel fur-
nace.

The chimney connector of the furnace is to be

installed to provide clearances to combustible
material not less than specified in the individual
classifications and marked on the furnace. The
chimney connector must be connected to a    chim-
ney suitable for use with residential type or building
heating appliances which burn solid fuel.

The furnace is designed to operate in either

parallel or series air flow arrangement with the
central furnace or as a central furnace.
CENTRAL FURNACE INSTALLATION: As a cen-
tral furnace, the unit functions independently of
any other system. The blower will come on when
the plenum temperature reaches the  setting on the
blower control.

HOW THE FURNACE FUNCTIONS

Your Furnace is designed to be installed in a parallel air flow arrangement with a gas or oil-fired
forced air upflow-type central furnace, or it may be installed as a central furnace.

CARING FOR PAINTED PARTS - This furnace has a painted outside jacket, which is durable but it
will not stand rough handling or abuse. When installing you furnace, use care in handling. Clean with
soap and warm water when furnace is not hot. DO NOT use any acids or scouring soap, as these
wear and dull the finish. DISCOLORATION WILL OCCUR IF THE FURNACE IS OVERFIRED.
FOLLOW OPERATING INSTRUCTIONS CAREFULLY.

Keep the feed and ash doors closed at all times except while tending the furnace.

14.

15.

RULES FOR SAFE INSTALLATION AND OPERATION

PARALLEL INSTALLATION: The design is such
that when the blower comes on, the blower on the
central system also comes on.

The blower will only come on when the

temperature in the plenum has reached the  setting
on the blower control. This is to insure that there is
sufficient warm air in the system to make it
efficient for the unit to operate. When the central
system thermostat calls for heat, the central sys-
tem will operate by the burner igniting and the
blower coming on. It is possible that both systems
will operate simultaneously. It is recommended
that for the most efficient use of your Ashley
Furnace, that it be fired as much as possible in
order to reduce the demand on your existing central
heating system.  This unit has an Optional forced
draft kit that operates from a wall thermostat.
When the temperature falls below the setting on the
wall thermostat, the forced draft will come on. (U.S.
Stove Option 11 DIK)

The warm air supply outlet of the Ashley

furnace shall not be connected to the cold air return
inlet of the central furnace because the possibility
exists of components of the central furnace over-
heating and causing the central furnace to operate
other than is intended.
SERIES INSTALLATION: (U.S. & CANADA)
This type of installation uses only the blowers of
the existing central furnace.  The solid fuel fan/limit
control must also control the functions of the
existing furnace.  All electrical power must come
from a single branch circuit.

Содержание Ashley 22AF

Страница 1: ...E OR TRAILER 851533A FOR INSTALLATION AS A CENTRAL FURNACE CERTIFIED UNDER ANSI UL 391 CAN CSA B366 1 M91 C R US Model 22AF OWNER SMANUAL SOLID FUEL WARM AIR FURNACE UNITED STATES STOVE COMPANY 227 Industrial Park Road P O Box 151 South Pittsburg TN 37380 423 837 2100 Keeping North America W Keeping North America W Keeping North America W Keeping North America W Keeping North America Warm Since 18...

Страница 2: ... or Existing Masonry Chimney SEE Page 8 Electrical Wiring 6 Draft Regulator 1 2 Conduit ConduitConnectors FurnaceCement ManufacturerRecommends Rutland Black Code 78 or Equivalent Plenum and Duct Work as Required CONGRATULATIONS You ve purchased one of America s Finest Wood and Coal Burning Furnaces By heating with wood and coal you re helping to CONSERVE AMERICA S ENERGY Wood is our Renewable Ener...

Страница 3: ...operly installed a house fire may result For your safety follow the in stallation directions Contact local building or fire officials about restrictions and installation in spection requirements in your area SAFETY NOTICE DANGER RISK OF FIRE OR EXPLOSION DO NOT burn garbage gasoline drain oil or other flammable liquids WARNING FIRE HAZARD DO NOT operate with fire draft exceeding 06 inches W C DO N...

Страница 4: ... CRACKING BUILD ONLY SMALL FIRES ON FIRST USE To prevent injury do not allow anyone to use this furnace who is unfamiliar with the correct operation of the furnace For further information on using your furnace safely obtain a copy of the National Fire Protection Association NFPA publication Chimney s Fireplaces and Solid Fuel Burning Appliances NFPA 211 The address of the NFPA is Batterymarch Park...

Страница 5: ... fired forced air upflow type central furnace or it may be installed as a central furnace CARING FOR PAINTED PARTS This furnace has a painted outside jacket which is durable but it will not stand rough handling or abuse When installing you furnace use care in handling Clean with soap and warm water when furnace is not hot DO NOT use any acids or scouring soap as these wear and dull the finish DISC...

Страница 6: ...6 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY MODEL 22AF DIMENSIONS FIG 1 ...

Страница 7: ...mm Unit to backwall 30 760 mm Chimney connector pipe to sidewall 18 530 mm Chimney connector pipe to backwall 18 460 mm Hot air ducts to combustibles 2 50 mm NOTE Install only on a noncombustible floor REFER TO FIG 2 3 Place the furnace on a noncombustible floor Check figures 2 and 3 Be sure you have the clearances shown from the furnace and the connector pipe to combustible surfaces If you have a...

Страница 8: ...he flue liner to be sure it is safe to use Make repairs before attaching the furnace See Page 4 item 5 Look at Fig 4 The connector pipe and fittings you will need to connect directly to a masonry chimney are shown The chimney connection should be as short as possible If the connector pipe must go through a combustible wall before entering the masonry chimney consult a qualified mason or chimney de...

Страница 9: ...tal screws at each chimney pipe joint to make the piping rigid Thechimneyconnectormayincludeasec tionforabarometricdraftregulatorbetween the furnace and the chimney Fig 4 5 6 7 The barometric draft regulator must be installed in the same room same pressure zone as the furnace Installthebarometricdraftregulatorstrictly in accordance with the instructions that are providedwiththebarometricdraftregul...

Страница 10: ...himney connector can be connected to a masonry chimney by passing through a combustible wall NFPA Standard 211 allows the following wall pass through systems FIGURE 8 CONNECTION OF CHIMNEY CONNECTOR TO A MA SONRY CHIMNEY THROUGH A COMBUSTIBLE WALL MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 AIRTIGHT CLEANOUT DOOR FLOOR PROTECTOR COMBUSTIBLE WALL TO HEATER CHIMNEY CONNECTOR CEILING SEE PARTS A B C D AN...

Страница 11: ...mney connector by means of sheet steel support plates on both ends of the chimney section The opening in the combustible wall shall be covered and the chimney section supported on both sides with sheet steel supports which are at least 24 gauge 0 024 in thickness The sheet steel supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold the chimney section...

Страница 12: ...NFPA 211 SHEET STEEL SUPPORTS 24 GAUGE MIN THICKNESS CHIMNEY FLUE MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY WHEN CHIMNEY CONNECTOR DOES NOT PASS THROUGH A COMBUSTIBLE WALL PART E Figure 8 In addition to the methods shown by A B C and D of Figure 8 a listed factory built wall pass through system may be ...

Страница 13: ...t using two 2 10 x 1 2 Tek screws Then Mount the bracket to the rear of the furnace with four 4 10 x 1 2 Tek screws Also Attach the Conduit from the Limit Control to the Junction Box 4 Installthefive 5 ClipNutstothebackofthefurnace InstalltheBlower 3 andBlowerGasket 4 tothefurnace using the 1 4 20 x 3 4 bolts provided in the parts bag Attach the remaining piece of Conduit from the junction box to ...

Страница 14: ... LOAD LIMIT LINE BREAK OFF JUMPER FOR LOW VOLTAGE FAN OFF INDICATOR FAN ON INDICATOR LIMIT INDICATOR Honeywell LIMIT SWITCH R1 R2 G W 110 VAC 60 HZ GROUND G B W ELECTRICAL JUNCTION BOX M1 M2 BLOWER MOTOR B WIRE NUTS IMPORTANT POWER SUPPLY WIRING MUST NOT BE LESS THAN 90 CENTIGRADE Fig 10 WIRECOLORCODE G GREEN GROUND B BLACK POWER SUPPLY W WHITE POWER SUPPLY R1 WHITE FAN CONTROL R2 BLACK FAN CONTRO...

Страница 15: ...ing Furnace as close as practical to the existing central hot air heating system maintainingclearancesasstatedonthelabellocatedon the side of the furnace c Clearances from combustible materials must be complied with as stated on the label below the fuel door Theinstallationmustbemadeonlyonanoncombustible floor d Installthesmokepipeconnectortothechimney with 26 gauge pipe and elbows to be purchased...

Страница 16: ...CTIONS Operation after loss of power Remove filter if provided Do not expect to keep home at normal temperatures Do not load fuel above bottom of feed door Set Fuel door and Ash door spin draft maximum closed per the factory installed stops 1 2 3 4 U S ONLY FIG 11 ...

Страница 17: ...17 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY CENTRAL INSTALLATION U S CANADA FIGURE 12 ADD ON INSTALLATION U S ONLY FIGURE 13 ...

Страница 18: ...COMBINATION CONTROL LIMIT FAN JUMPER IN H H POWER SUPPLY GAS OIL ELECTRIC POWER SUPPLY JUNCTION BOX CENTRAL FURNACE BLOWER MOTOR WOOD FURNACE BLOWER MOTOR CAUTION DO NOT CONNECT PLENUM FAN CONTROL SWITCH ACROSS FURNACE LIMIT CONTROL This unit is certified for parallel installation with exitsting forced air gas or oil fired furnace U S Only ...

Страница 19: ...or residential furnaces or any of the specially packed fireplace coals can be used Coalwithalowashcontent 2 to6 isrecommended WOODFUEL Hardwood 18 to26 shouldbesplitandairdried seasoned for 6 months LIGHTING 1 2 3 4 Open the draft controls to HIGH for maximum draft Openthefeeddoorandplacepaperandkindlingonthegrate for starting the fire Light the fire and close the feed door Add wood or about 15 lb...

Страница 20: ...of the chimney should be at least 3 feet above the roof and be at least 2 feet higher than any point of the roof within 10 feet Fig 5 See page 28 for list of trouble shooting tips 4 5 6 A DRAFT READING OF 05 TO 06 W C IS SUGGESTED FOR PROPER BURNING OF THIS UNIT WHEN USING WOOD SERVICE HINTS Creosote and Soot Formation and Need for Removal When wood is burned slowly it produces tar and other organ...

Страница 21: ...21 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY MODEL 22AF PARTS ...

Страница 22: ...uit Assembly 1 24 80131 4 x 4 Junction Box 1 N S 80231 JunctionBoxCover 1 25 68232 Blower Connection Conduit Assembly 1 26 80230 Blower Motor 1 20 hp 1 27 40256 Grate Frame 1 28 40257 Shaker Grate 1 29 40260 Shaker Handle 1 69355 FeedDoorAssembly OrderONLYiftheentireAssemblyisneeded 1 30 25105B Feed Door Painted 1 N S 88066 5 8 Rope Gasket 4 58 ft 31 83872 Door Pin 2 32 89354 Feed Door Handle 1 33...

Страница 23: ...23 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY APPENDIX INSTALLATIONA NOTE ANTI BACKDRAFT FLAPPERS OR BAFFLE ARE REQUIRED FOR THIS INSTALLATION ...

Страница 24: ...24 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY APPENDIX INSTALLATIONB NOTE ANTI BACKDRAFT FLAPPERS OR BAFFLE ARE REQUIRED FOR THIS INSTALLATION ...

Страница 25: ...25 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY APPENDIX INSTALLATIONC NOTE ANTI BACKDRAFT FLAPPERS OR BAFFLE ARE REQUIRED FOR THIS INSTALLATION ...

Страница 26: ...26 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY APPENDIX INSTALLATION D U S ONLY INSTALLATION E U S ONLY ...

Страница 27: ...27 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY APPENDIX INSTALLATION F INSTALLATION G ...

Страница 28: ... a Burning green wood not seasoned or dry b Thermostat setting too low for type fuel a Insufficient draft b Smothering fire when adding fresh fuel a Open spin dampers b Clean chimney c Add raincap to chimney a Allow wood to season in a dry well ventilated area for six months b Set blower control to higher temperature See Page 19 c Set flue draft See Page 9 a Wire unit properly b Replace blower con...

Страница 29: ...29 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY NOTES ...

Страница 30: ...30 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY NOTES ...

Страница 31: ...White Oak 48 4100 9 Fair 28 6 Red Oak 46 3900 8 Fair 27 4 Beech 45 3800 7 Hard 26 8 Sugar Maple 44 3700 6 Fair 26 2 Black Oak 43 3700 6 Fair 25 6 Ash 42 3600 5 Well 25 0 Yellow Birch 40 3400 4 Hard 23 8 Red Maple 38 3200 3 Fair 22 6 Paper Birch 37 3100 3 Easy 22 1 Elm Sycamore 34 2900 2 Very Difficult 20 1 Red Spruce 29 1800 1 Easy 16 1 HEATING WITH WOOD ...

Страница 32: ...VE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST 1 THE PART NUMBER 2 THE PART DESCRIPTION 3 THE MODEL NUMBER 22AF 4 THE SERIAL NUMBER ____________________ HOW TO ORDER REPAIR PARTS UNITED STATES STOVE COMPANY 227 INDUSTRIAL PARK ROAD P O BOX 151 SOUTH PITTSBURG TN 37380 423 837 2100 WWW ...