USR-DR404 user manual
Jinan USR IOT Technology Limited
84
Parameter takes affect after restarting the module.
4.3.4.67. AT+MODBPOLLEN
Function: Enable/Disable Modbus polling function
Format:
AT+MODBPOLLEN =on/off<CR>
+ok<CR>< LF ><CR>< LF >
Default is “off”. Parameter takes affect after restarting the module.
4.3.4.68.AT+UPDATE
Function: Query/Set remote upgrade parameters.
Format:
Query : AT+UPDATE<CR>
+ok=<state, server address, server port, interval ><CR>< LF ><CR>< LF >
Setting: AT+ UPDATE =< state, server address, server port, interval ><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
state: status,
on/off
server address: server address
default: ycsj1.usr.cn
server port: server port
Default: 30001
interval: reporting interval
Default is 30min, maximum time interval (max): 120min
Parameter takes affect after restarting the module.