manualshive.com logo in svg
background image

 

Instructions Manual – Eline NPE 

12/21/2011 

 
 
 

STORAGE 

 

Units should be stored indoors, in a clean, dry location and winding should 

be protected from excessive moisture absorption.  

NOTE

: If motors are to be 

stored for more than one year, refer to US Motors. 

 
 
 

MAINTENANCE 

 

Inspect units at regular intervals. Keep units clean and ventilation openings clear 
of dust, dirt or other.  

WARNING: 

Disconnect all power sources to the unit and 

discharge all parts, which may retain an electrical charge before attempting any 
maintenance or repair Screen and covers must be maintained in place when unit 
is in operation Failure to observe this warning may result in personal injury.  All 
actions connected with installations of the motor shall be made by a qualified 
person. 

 
 
 

GREASE LUBRICATION INSTRUCTIONS 

 

Units are pre-lubricated at the factory and do not require any additional 
lubrication 

 
 
 

BEARING LIST 

 

E|ine 

Frame 

size  

Bearing 

Type DE & 

ODE 

140T 6205 

2Z 

C3 

180T 6306 

2Z 

C3 

210T 6308 

2Z 

C3 

250T 6309 

2Z 

C3 

280T 6311 

2Z 

C3 

 

Содержание NEMA Eline Series

Страница 1: ...Instructions Manual Eline NPE 1 12 21 2011 _____ _ INSTALLATION AND MAINTENANCE MANUAL...

Страница 2: ...sonnel in order to prevent possible accidents 7 Be sure shaft key is fully captive before unit is energized 8 Avoid contact with capacitors until safe discharge procedures have been completed 9 Provid...

Страница 3: ...urces to the unit and discharge all parts which may retain an electrical charge before attempting any maintenance or repair Screen and covers must be maintained in place when unit is in operation Fail...

Страница 4: ...to prevent vibration Drive belts and chains should be tensioned in accordance with supplier recommendations Couplings should be properly aligned and balanced For belt chain and gear drive selection re...

Страница 5: ...as measured with a 500V magneto Resistance control device between each phase and frame indicates excess moisture requiring that the windings be dried before installation WARNING Guards should be prov...

Страница 6: ...nected according to the following diagrams Connection Diagram for Frames 143T to184T nominal voltage 230 460V Connection Diagram for Frames 213T to 286T nominal voltage 230 460V Connection Diagram for...

Страница 7: ...with unscrewed conduit box After taking out the motor from the carton the conduit box should be assembled accordingly to the drawing below 1 Motor frame 140 2 T B body seal 3 Terminal box body 4 Scre...

Страница 8: ...Instructions Manual Eline NPE 8 12 21 2011 SERVICE For after sales service and warranty questions refer to you local US Motors representative or visit our website at www usmotors com...

Отзывы: