CAUTION:
PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TO
PREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.
WARNING:
Before installing or maintaining the luminary, make sure all powers are
TURNED OFF
.
Verify that supply voltage is correct by comparing it with the label information on all
fixtures.
Make all connections in accordance with the NEC requirements, and make sure all
luminaries are properly secured to prevent any wire complications. This luminary is
to always be installed with the lens facing down and its not to exceed the maximum
ambient temperature rating noted on the specification sheet.
USSLxxxWPL
Series LED Area Light
Installation Sheet
STANDARD INSTALLATION STEPS
DRILLING TEMPLATE
5.50 in
4.25 in
7. Adjust the Tilt Angle on the
luminaire,
once the Tilt Angle is as
desired, finish
tightening the Socket
Head bolt to firmly
tighten the
fixture
with
the Arm Mount.
LED DRIVER
V(-)
[BLACK]
V(+)
[RED]
TO LOAD
[LED BOARD]
[WHITE]
[BLACK]
ACN [BLUE/WHITE]
ACL [BROWN/BLACK]
GROUND [GREEN]
NEUTRAL [WHITE]
GROUND [GREEN]
HOT [BLACK]
INPUT
OUTPUT
DIM
WHITE (-)
BL
UE(+)
Inside F2SB
PRE-CONNECTED
(DO NOT DISCONNECT)
Using a J-Box (not included), Connect the ACL and the ACN from the driver to the conduit with the AC Power Supply cords.Follow the Wiring Diagram provided.
* LED DRIVER Input Ground (green) wire only available for selected fixtures.
If the Ground Wire is missing and the Power Supply includes a ground wire, connect the power supply ground wire to the fixture.
(FOR DIMMABLE VERSION)
3.6875 in
.625 in
2. Place mount against round tube.
3. Install the provided [2] Socket head
M8-1.25 x 40 mm bolts with lock washer and
washer to secure the Mount firmly
in place, insert the flatbar with threaded holes
inside the round tube and use the threaded
holes to secure the mount. Make sure all
bolts are tightened and holes are
properly sealed.
1. Use provided Hole Pattern for drilling. Make sure to make an extra notch for
the power cables to run through the Round Tube.
ARM MOUNT (ROUND POLE)
CAUTION:
PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TO
PREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.
WARNING:
Before installing or maintaining the luminary, make sure all powers are
TURNED OFF
.
Verify that supply voltage is correct by comparing it with the label information on all
fixtures.
Make all connections in accordance with the NEC requirements, and make sure all
luminaries are properly secured to prevent any wire complications. This luminary is
to always be installed with the lens facing down and its not to exceed the maximum
ambient temperature rating noted on the specification sheet.
Includes:
F2SB048, F2SB080,
F2SB100,
F2SB150,
F2SB200,
F2SB300
F2SB Series LED Area Light
Installation Sheet
0200015-170815-1
Need help? Tech help line:
(800) 988-6386
Email:
Website:
www.paclights.com
Copyright © 2017 PacLights
All Rights Reserved Note: Instructions are subject to change at any time without notice
(F2SB048)
STANDARD INSTALLATION STEPS
MOUNTING METHODS:
Please select the installation instructions based on proper mounting method:
SKU
Description
AC2SBF
Slipfitter Mount for 2 3/8 inch OD (2” Pipe
Bracket) Tenon (0º to 90º Vertical Aiming Angle)
AC2SBTM Trunnion Mount
AC2SBAM1 6” Arm Mount for Square Pole
AC2SBAM2 6” Arm Mount for Round Pole
LED DRIVER
V(-)
[BLACK]
V(+)
[RED]
TO LOAD
[LED BOARD]
[WHITE]
[BLACK]
ACN [BLUE/WHITE]
ACL [BROWN/BLACK]
GROUND [GREEN]
NEUTRAL [WHITE]
GROUND [GREEN]
HOT [BLACK]
INPUT
OUTPUT
DIM
WHITE (-)
BL
UE(+)
Inside Junction Box
(Not Included)
PRE-CONNECTED
(DO NOT DISCONNECT)
1. Connect the ACL and the ACN from the driver to the conduit with the AC Power Supply cords.Follow the Wiring Diagram provided.
* LED DRIVER Input Ground (green) wire only available for selected fixtures.
If the Ground Wire is missing and the Power Supply includes a ground wire, connect the power supply ground wire to the fixture.
(FOR DIMMABLE VERSION)
AC2SBF
AC2SBAM1
AC2SBAM2
AC2SBTM
TROUBLESHOOTING
1) Make sure the Power Outlet matches the Voltage on the driver. It is very
important for the Power Outlet and the driver to match. If these values do not match,
this can cause the LED fixture to not turn on or damage the driver.
2) Check the LED Driver Input Connections. Make sure the ACL on the driver is
connected to the hot power outlet cable and the ACN on the driver is connected to the
Neutral wire on the power outlet.
3) Check the LED Driver Output Connections. These connections will already come
installed when the fixture is purchased. However, if the Input Connections are double-
checked and the lumen is not turning on. It might be a good idea to make sure there are
no cuts in the wires and everything is properly connected.
Please select the installation instructions based on proper mounting method:
SKU
Description
AC2SBPS Photocell,Twist Lock, 1.5 FC, 120-277 vAC, Instant On, 2-5 sec
OFF Delay
AC2SBPS480 Photocell,Twist Lock, 1.5 FC, 480 vAC, Instant On, 2-5 sec
OFF Delay
AC2SBSU Surge Protector. VMAX AC: 277v, maximum Lightning Surge
Current: 20,000A
AC2SBSU480 Surge Protector. VMAX AC: 277v, maximum Lightning Surge
Current: 20,000A
OPTIONAL ADDONS
5.
Run the power cord from the arm mount to the luminaire, Once the cable
has
been inserted inside the
fixture
, connect the power cable to the LED Driver inside
the
fixture
. In order to access the LED Driver cables, the electrician must first remove
the
[6] screws from the service door using a #2 Phillips screw driver and make all
connections inside the luminaire.
6.
Once all wiring is complete,
Close the service door and use
the M12 bolt to fasten the
Arm Mount to the
fixture
.
Do not fasten completely.
4. Once the Arm Mount is properly
fastened to the mounting round pole, run
the power cord cable from the inside of
the pole and out the notch from the
Arm Mount. This cable
will then be inserted into
the fixture.