USA Measurements US-PC-PH-15 Скачать руководство пользователя страница 16

 

                                                          US-PC-PH & US-PC-PL 

  . 

14 

.

 

          <LF>Tare:              xxx.xxx kg(or lb)<CR> <EXT> 
          <LF>Net:                xxx.xxx kg(or lb)<CR> <EXT> 
          <LF>Unit    price: xxxxxx.xx $/kg(or $/lb)<CR><EXT> 
          <LF>Total price: xxxxxx.xx $<CR> <EXT> 
NOTE

The ID information can only be printed out after setting. 

        Press Enter key to confirm the input and go to the next step, or use ON/OFF key to exit this mode. 

7.    RS-232 connects between scale and host

 

  SCALE(Indicator) -------CABLE

9 pins

----------------------------HOST 

DB9(Female)-------------DB9(Male)--------DB9(Female)-----------DB9(Male) 
PIN2 TXD------------------2--------------------2---------------------------PIN2    RXD 
PIN3 RXD------------------3--------------------3---------------------------PIN3    TXD 
PIN5 GND------------------5--------------------5---------------------------PIN5    GND 
PIN4 DSR------------------4--------------------4---------------------------PIN4    DTR 
PIN6 DTR------------------6--------------------6---------------------------PIN6    DSR 
PIN7 CTS------------------7--------------------7---------------------------PIN7    RTS 
PIN8 RTS------------------8--------------------8---------------------------PIN8    CTS 
PIN1 NC--------------------1--------------------1---------------------------PIN1    NC 
PIN9 NC--------------------9--------------------9---------------------------PIN9    NC 
Note: PIN4 and PIN6, PIN7 and PIN8 are shorted in the scale! 
 

8. RS-232 cable connects between scale and OS-2130D

 

 

 

 

 

 

 

 

 

 

9.

9.

9.

9.

 

Date and time setting

Date and time setting

Date and time setting

Date and time setting         

1.    Under the normal working mode, press and hold 5 and ON/OFF key for more than 3s to enter into this mode. In this   

      mode, you can set the system date and time.

Note: the date and time in scale will be lost after the scale power off if   

      no RTC module is installed

 

2.    After entering into this mode, the WEIGHT window will display “SETUP”, the UNIT PRICE window will display   
      “dAtE”(date, prompt to input date) and the TOTAL PRICE will display the current date xx.xx.xx. Use the numerical   
      keys to input the date (format: YY.MM.DD), use Enter key to confirm and go to the time setting mode.   
3.    When the WEIGHT window remains “SETUP”, the unit price displays “TiME”(time, prompt to input time) and the   

      TOTAL PRICE window displays the current time xx.xx.xx, Use the numerical keys to input the time (Format: hh.mm.ss)

 

      press Enter key to confirm the input and exit this mode. 
 

10.

10.

10.

10.     Business name setting

Business name setting

Business name setting

Business name setting         

Содержание US-PC-PH-15

Страница 1: ...US US US US P P P PC C C C PH PH PH PH US US US US P P P PC C C C PL PL PL PL User Technical Manual Contents subject to change without notice Version 1 0 01 2022...

Страница 2: ...g 10 6 6 6 6 Auto Auto Auto Auto off time setting off time setting off time setting off time setting 11 7 7 7 7 Display A D inner code and working voltage Display A D inner code and working voltage Di...

Страница 3: ...n storing the scale for extended periods the battery must be charged every 60 days to avoid premature performance degradation If the operating time is no longer acceptable even after recharging the ba...

Страница 4: ...us use when backlight is on with 12 hour recharge time when the battery voltage is below 5 6v Lo bat is displayed and beep for 10 seconds and then auto off Platter size LxD 288x210 2 2 2 2 Unpacki Unp...

Страница 5: ...d US PC PL Follow below procedure to install the tower display 1 Pass the socket on bottom of scale base through the pole bracket and plug it to the connector 2 Connect the column to the base and tigh...

Страница 6: ...splay reading is net weight tare is not not not not 0 SAVE SAVE SAVE SAVE Unit price fixing indicator k k k kg g g g lb lb lb lb oz oz oz oz Weight unit indicator UNIT PRICE UNIT PRICE UNIT PRICE UNIT...

Страница 7: ...Used to clear the recorded data ENT ENT ENT ENTER ER ER ER Used to confirm the operation or entered data SAVE SAVE SAVE SAVE Save the tare weight and unit price when input the unit price so that the...

Страница 8: ...lay A D inner code or working voltage ON OFF ON OFF ON OFF ON OFF 4 4 4 4 Used to enter RS232 parameters setup mode ON OFF ON OFF ON OFF ON OFF 5 5 5 5 Used to enter the date and time setup mode ON OF...

Страница 9: ...g to resolve 4 To change the weighing unit of measure press the Unit key to toggle between kg lb or oz 5 Set the tare weight if desired 6 Place objects on the scale platter and read the weight on the...

Страница 10: ...press the RC PLU key Press the ON OFF key to return to weighing Note Note Note Note The previously stored tare weight can only be recalled with the RC PLU key when in tare setting mode c To clear the...

Страница 11: ...it total value Note After unit price is entered if there is no operation in 3s the scale with automatically confirm the unit price and exit the mode If under non save mode the unit price will be clear...

Страница 12: ...it tare the UNIT PRICE window displays the entered data 14 Use the numerical keys 0 9 CLEAR key to input the tare weight use ENTER key to store and confirm 15 The TOTAL PRICE window displays ItEm C se...

Страница 13: ...ime till the UNIT PRICE window shows CodE 2 to enter this mode Now WEIGHT window will show UoL x x Voltage x x V this means the inner working voltage is x x V If the scale uses AC power adaptor the vo...

Страница 14: ...r key to confirm the input and go to the next step or use ON OFF key to exit this mode 6 Then the UNIT PRICE window shows USb oUt USB output content format and the TOTAL PRICE window shows HOST the sc...

Страница 15: ...igits P Total Price If the weight window display zero it will be unit price W Weight C Check sum for all characters Press ENTER key to confirm press ON OFF key to exit Note if the price weight or code...

Страница 16: ...ing Date and time setting Date and time setting 1 Under the normal working mode press and hold 5 and ON OFF key for more than 3s to enter into this mode In this mode you can set the system date and ti...

Страница 17: ...setting 1 Under the normal working mode press and hold 6 and ON OFF key for more than 3s to enter this mode In this mode you can set ID code Note the data will be lost after the scale reset 2 The wei...

Страница 18: ...xls files The following is Example for US PC PH 1530 2 Software searches all serial ports on PC and tries to connect with the scale In the Status bar it will separately display present serial port bau...

Страница 19: ...US PC PH US PC PL 17...

Страница 20: ...the information of PLU1 250 Download successful will be displayed after downloading finished In downloading to use Serial Download Stop or F9 can stop down load PLU 6 Choose Upload in Serial menu the...

Страница 21: ...alibration mode the WEIGHT window will display CAL ON which means the calibration switch is on The UNIT PRICE window displays Unit 0 or Unit 1 which means the chosen calibration weighing unit is kg Un...

Страница 22: ...window and then please remove any weight on the scale 7 When the WEIGHT window displays unLoAd again the scale is ready to re confirm the zero point remove any weight on the scale after the scale is r...

Страница 23: ...splay not go to 0 Something wrong with the keys or faulty PCB board or Load cell Check the key button Replace the PCB or load cell Missing segment or marks on LCD LCD connect pin broken Replace LCD Po...

Страница 24: ...dust proof wash Clear the objects Replace the load cell Calibration can t be finished The inner code at zero point is too small or too big not enough with the full capacity inner code not stable ther...

Отзывы: