Page 29
RELAY OUTPUT
The indicator can output 4 signals, which when connected to outside equipment, can perform
an automatic control function and an upper/lower limit alarm function. You can change
parameter setting C33 following Table 6 below:
Table 6: Relay Output Parameter Setting
Output
Port
Port Definition
Function
C33=0
Out1
Turn off output
function
No Output Signal
Out2
Turn off output
function
No Output Signal
Out3
Turn off output
function
No Output Signal
Out4
Turn off output
function
No Output Signal
C33=1
Out1
Turn on overload
control function
Output overload control signal
Out2
Turn on compliance
control function
Output compliance control signal
Out3
Turn on under-load
control function
Output under-load control signal
Out4
Turn on stable
control function
Output stable control signal
C33=2,3
Preserved, no function
The RS232 port for the relay output option is shown in the Table 7 below, which also includes
a definition of its pin.
Table 7: Relay Output Pin Definition
DB�9 Pin
Definition
Port
1
Red
1
st
output signal pin
Out1
6
Red
1
st
output signal pin
Out1
2
Green
2nd output signal pin
Out2
7
Green
2nd output signal pin
Out2
3
White
3rd output signal pin
Out3
8
White
3rd output signal pin
Out3
4
Black
4th output signal pin
Out4
9
Black
4th output signal pin
Out4