19
System Start-Up
1. Plug the valve into an approved power source.
2. When power is supplied to the control, the screen will display “INITIALIZING WAIT
PLEASE” while it finds the service position.
3. Start an Immediate Manual Regeneration. The valve will immediately start moving to the
BACKWASH position.
4. Partially open the inlet on the bypass valve
slowly
and allow water to enter the unit. Allow
all air to escape from the unit before turning the water on fully then allow water to run to
drain for 3-4 minutes or until all media fines are washed out of the filter indicated by clear
water in the drain hose.
5. Press any button to advance to the RINSE position. Slowly open the bypass inlet valve
during the rinse cycle until it is fully opened. Check the drain line flow. Allow the water to
run for 3-4 minutes or until the water is clear.
6. The valve will automatically advance to the SERVICE position after the RINSE cycle is
complete. Open the outlet valve on the bypass, then open the nearest treated water fau-
cet and allow the water to run until clear, close the tap and replace the faucet screen.
7. Program time, date, and number of days between regenerations into controller using the
following Programming Instructions
Start-up Instructions
Key Pad Configuration
DELAYED REGENERATION
Press and release the MANUAL REGEN.
Button to set a delayed regeneration that will
occur at the regeneration time. The main dis-
play page will show DELAYED REGEN ON.
To cancel press and release the MANUAL
REGEN. Button. The main display page will
show DELAYED REGEN OFF.
IMMEDIATE REGENERATION
To start an immediate regeneration (or step
valve through each position), press and hold
the MANUAL REGEN. Button for 3 seconds
(until beeps). The valve will start an immedi-
ate regeneration. Press any key to skip to
the next cycle.
Manual Regeneration (Step / Cycle Valve)
SET-
TINGS
This function is to enter the basic set up
information required at the time of installa-
tion.
MANUAL
REGEN
This function is to initiate an immediate or
delayed manual regeneration.
DOWN /
UP
Increase or decrease the value of the set-
tings while in the programming mode.