7
REVISION 1.0, 1-19-15
SYSTEM INSTALLATION AND START-UP PROCEDURES
1. Inspect the system for any damage that could have occurred during shipment. Although all sys-
tems have been individually inspected, complete a quick inspection of the fittings, tubing and other
components.
2. Please provide a reasonable amount of space for installation and leave 6 inches of space below the
filter housings for easy removal during maintenance endeavors.
NOTE: THE REVERSE OSMOSIS SYSTEM SHOULD BE INSTALLED
INDOORS AND IT IS SUGGESTED THAT IT NOT BE IN DIRECT SUNLIGHT OR
EXTREME COLD.
3. Connect the 3/8” tube fitting to an incoming water source. The minimum feed water pressure
should be at least 30 psi. The system’s minimum operating (membrane) pressure is 80 PSI, but the
optimum operating pressure is 100 psi.
NOTE: DO NOT OPERATE AT A PRESSURE EXCEEDING 125 PSI.
The operating
pressure
can be increased on the face of the booster pump by turning the hex screw clock-
wise.
4. Connect the concentrate 3/8” tubing (waste) line to drain.
5. Turn on the feed water and plug the booster pump transformer into a power supply of 110 volts 60 Hz.
6. This system has been designed with an auto-flush restrictor. This restrictor automatically flushes the
reverse osmosis system for 30 seconds every time it starts up and once every hour when the system is
producing water.
NOTE: THE TANK PRESSURE SWITCH WILL SHUT THE SYSTEM OFF
AUTOMATICALLY WHEN THE BLADDER TANK IS FULL.
Содержание L1-200
Страница 1: ...1 REVISION 1 0 1 19 15 US Water Systems 300 GPD Premium Wall Mount Light Commercial RO System...
Страница 9: ...9 REVISION 1 0 1 19 15...
Страница 10: ...10 REVISION 1 0 1 19 15...
Страница 11: ...11 REVISION 1 0 1 19 15...
Страница 12: ...12 REVISION 1 0 1 19 15 SYSTEM IDENTIFICATION...
Страница 17: ...17 REVISION 1 0 1 19 15 SPECIFICATIONS...
Страница 24: ...24 REVISION 1 0 1 19 15 SYSTEM DRAWING...
Страница 25: ...25 REVISION 1 0 1 19 15 L1 300 FLOW DIAGRAM...
Страница 26: ...26 REVISION 1 0 1 19 15 L1 SERIES ELECTRICAL SCHEMATIC 110V 60HZ...
Страница 27: ...27 REVISION 1 0 1 19 15 L1 SERIES ELECTRICAL SCHEMATIC 220V 50HZ...