DIAGNOSTIC PROGRAMMING MODE   

 
 

Diagnostic Programming Mode Options 

Abbreviation 

Parameter 

Description 

FR 

Flow Rate 

Displays the current outlet flow rate 

PF 

Peak Flow 

Rate 

Displays the highest flow 

rate measured since the last 

regeneration 

HR 

Hours in 

Service 

Displays the total hours that the 

unit has been in service 

VU 

Volume Used 

Displays the total volume of water 

treated by the unit 

RC 

Reserve 

Capacity 

Displays t

he system’s reserve 

capacity calculated from the system 

capacity, feedwater hardness, and 

safety factor 

SV 

Software 

Version 

Displays the software version 

installed on the controller 

 

NOTE: Some items may not be shown depending on timer configuration. The timer will exit Diagnostic Mode after 60 

seconds if no buttons are pressed. Press the Extra Cycle button to exit Diagnostic Mode at any time. 

Diagnostic Programming Mode Steps 

1.  Press the Up and Extra Cycle buttons for five seconds while in service. 

2.  Use thi

s display to view the current Flow Rate. This option setting is identified by “FR” in the upper left hand corner of the 

screen. 

 

3.  Press the Up button. Use this display to view the Peak Flow Rate since the last regeneration cycle. This option setting is 

ide

ntified by “PF” in the upper left hand corner of the screen. 

 

4.  Press the Up button. Use this display to view the Hours in Service since the last regeneration cycle. This option setting is 

identified by “HR” in the upper left hand corner of the screen. 

 

5.  Press the Up button. Use this display to view the Volume Used since the last regeneration cycle. This option setting is 

identified by “VU” in the upper left hand corner of the screen. 

 

 

6.  Press the Up button. Use this display to view the Reserve Capacity. Thi

s option setting is identified by “RC” in the upper 

left hand corner of the screen. 

 

 

Содержание Fusion

Страница 1: ...Fusion Fusion Hybrid and Prelude Water Softener Service Manual IMPORTANT Fill in Pertinent Information on Page 3 for Future Reference ...

Страница 2: ...t the time of installation If daytime operating pressure exceeds 80 psi nighttime pressures may exceed pressure limits A pressure reducing valve must be installed Do not install the unit where temperatures may drop below 32 F 0 C or above 125 F 52 C Do not place the unit in direct sunlight Black units will absorb radiant heat increasing internal temperatures Do not strike the valve or any of the c...

Страница 3: ...B 164 minute available regeneration time 1 30 RPM 2 Type of Meter Mechanical Valves Gallon Settings Meter Standard Range Extended Range 3 4 125 2 125 625 10 625 1 310 5 270 1 150 26 350 1 1 2 625 10 625 3 125 53 125 3 Timer Gallon Setting Gallons 4 Regeneration Program Setting A Backwash ___________________ Minutes B Brine and Slow Rinse _________ Minutes C Rapid Rinse _________________ Minutes D ...

Страница 4: ...ion or watering from a spigot Grass and other plants do not like soft water and damage to the lawn or landscaping can occur 2 Check the distributor tube in each tank and make sure they are secured to the tank if the system is using Vortech tanks If the system is using standard tanks the distributor will be loose in the tank with a lower basket on the tube For standard tanks make sure the distribut...

Страница 5: ...rge units pour the gravel in first Pour the resin in the tank next The tank should be 60 80 full when the media is installed Use all the resin that was shipped with the unit 6 During cold weather it is recommended that the installer warm the valve to room temperature before operating 7 Perform all plumbing according to local plumbing codes including the drain Use a 1 2 minimum pipe tube size for t...

Страница 6: ...8 The distributor tube must be flush with the top of the tank Cut if necessary Remove the duct tape Lubricate the tube and nylon seal ring on the tank Use only non aerosol food grade silicone lubricant ...

Страница 7: ...9 Lubricate the distributor o ring seal and tank o ring seal on the control valve Install the upper basket by pushing in the slotted holes and turn it clockwise until it locks in place ...

Страница 8: ...the plumbing according to local codes The inlet and outlet pipes will attach to the 1 female threads on bypass valve The bypass valve will be labeled with arrows The inlet port will have an arrow pointing toward the unit and the outlet will have an arrow pointing away from the unit If soldering is necessary it is recommended that solder joints closer than 6 to the unit be completed prior to screwi...

Страница 9: ......

Страница 10: ...if tubing is not used Be sure not to over tighten this fitting 14 Once the fittings are installed and tight push the 5 8 drain line on the barb and secure it using a hose clamp This tube should be attached to a sanitary drain An air gap fitting should be installed on the drain pipe where this tube will be connected check local codes If this is being conveyed to a floor drain sink or sump pump be s...

Страница 11: ... place the nut over the tube install the brass sleeve in the tube Install the cone screen in brass insert Install the plastic flange over the tube Install the tube in the control valve and tighten the nut by turning it clockwise Tighten it hand tight then snug it an additional to turn ...

Страница 12: ...18 Remove the white cap from the white tube in the brine tank Place the other end of the tube through the hole in the side of the bine tank ...

Страница 13: ...19 Remove the nut from the brine safety valve BE CAREFUL not to drop the nut and sleeves 2 in the brine tube 20 Place the nut over the tube Be sure the brass insert is in the tube ...

Страница 14: ...21 Now place the black split ring on the tube with the coned side facing the nut 22 Now place the white ring on the tube with the shoulder touching the black split ring ...

Страница 15: ...23 Insert the tube in the brine safety valve elbow and tighten the nut by turning it clock wise Tighten the nut hand tight and snug it an additional to turn Place the white cap back on the white tube ...

Страница 16: ...salt should be used then refilled It is not a good practice to top off the salt weekly It is better to use it all then refill it 26 Place the unit in the Bypass position There is a pointer on the bypass valve handle This pointer should be pointing to bypass on the valve When the bypass valve is in the bypass position the handle will bisect the plumbing connections Turn on the main water supply Ope...

Страница 17: ...system The bypass valve pointer should be pointing toward service and the handle should be in line with the plumbing connections Electrical 28 Make all electrical connections according to codes Plug the valve into an approved power source 29 The valve position will be displayed on the control panel If the unit is in the regeneration process the cycle will be shown on the screen When the system is ...

Страница 18: ... be illuminated during programming or regeneration 7 The extra cycle button serves as an enter return button when programming The up and down arrows allow value changes in each parameter programming mode Once the value is reached the extra cycle button can be pushed to save the value and move to the next parameter 8 The extra cycle button also initiates immediate or delayed regenerations Pushing a...

Страница 19: ...will illuminate when values are multiplied by 1000 capacity setting 11 The system will hold the values for up to 48 hours after a power outage Outages exceeding 48 hours should have the programming values revisited It is a good idea to write down the programming parameters values so they are available if a reprogramming is required ...

Страница 20: ...ke certain the current supply is always energized and cannot be turned off with another switch EXISTING PLUMBING Condition of existing plumbing should be free from lime and iron buildup Piping that is built up heavily with lime and or iron should be replaced If piping is clogged with iron a separate iron filter unit should be installed ahead of the water softener LOCATION OF SOFTENER AND DRAIN The...

Страница 21: ...Cycle button at the last parameter to save all settings and return to normal operation The control will automatically disregard any programming changes and return to normal operation if it is left in Master Programming mode for 5 minutes without any keypad input Resets Soft Reset Press and hold the Extra Cycle and Down buttons for 25 seconds while in normal Service mode This resets all parameters ...

Страница 22: ...ter UFbd Upflow Brine First 8500 TwinFlo 100 Othr Other 3 Control Type Display Code CT Press the Extra Cycle button Use this display to set the Control Type This specifies how the control determines when to trigger regeneration For details on how the various options function refer to the Timer Operation section of this service manual This option setting is identified by CT in the upper left hand c...

Страница 23: ... desired volume capacity when configuring a filter system This option setting is identified by C in the upper left hand corner of the screen The Unit Capacity parameter is only available if the control type has been set to one of the metered options Use the Up and Down buttons to adjust the value as needed Range 1 999 900 gallons 100 9 999 000 Liters Use the following chart to determine your capac...

Страница 24: ...serve Selection Display Code RS Press the Extra Cycle button Use this display to set the Safety Factor Use this display to select the type of reserve to be used in your system This setting is identified by RS in the upper left hand corner of the screen The reserve selection parameter is only available if the control type has been set to one of the metered options There are two possible settings SF...

Страница 25: ...generate regardless of usage if the days since last regeneration cycle equal the day override setting Setting the day override value to OFF disables this function This option setting is identified by DO in the upper left hand corner of the screen Use the Up and Down buttons to adjust the value as needed Range Off 99 days This will most likely be set at 14 days unless you take vacations lasting mor...

Страница 26: ...ns to adjust the value as needed Press the Extra Cycle button to accept the current setting and move to the next parameter Abbreviation Cycle Step BW Backwash 10 Mins BD Brine Draw 60 Mins RR Rapid Rinse 10 Mins BF Brine Fill see chart Range 0 199 minutes This setting is determined by the chart used for the capacity setting Input the number of minutes that corresponds to the capacity setting that ...

Страница 27: ...g Mode USER PROGRAMMING MODE User Programming Mode Options Abbreviation Parameter Description DO Day Override The timer s day override setting RT Regeneration Time The time of day that the system will regenerate meter delayed timeclock and day of week systems H Feed Water Hardness The hardness of the inlet water used to calculate system capacity for metered systems RC or SF Reserve Capacity The fi...

Страница 28: ...fied by H in the upper left hand corner of the screen Range 1 199 hardness 5 Press the Extra Cycle button Use this display to adjust the Fixed Reserve Capacity This option setting is identified by RC or SF in the upper left hand Corner of the screen 6 Press the Extra Cycle button Use this display to set the Current Day of the Week This option setting is identified by CD in the upper left hand corn...

Страница 29: ...xit Diagnostic Mode at any time Diagnostic Programming Mode Steps 1 Press the Up and Extra Cycle buttons for five seconds while in service 2 Use this display to view the current Flow Rate This option setting is identified by FR in the upper left hand corner of the screen 3 Press the Up button Use this display to view the Peak Flow Rate since the last regeneration cycle This option setting is ident...

Страница 30: ... the Up button Use this display to view the Software Version This option setting is identified by SV in the upper left hand corner of the screen Press the Extra Cycle button to end Diagnostic Programming Mode ...

Страница 31: ...g B Excessive water in brine tank B See problem 7 4 Loss of water pressure A Iron buildup in line to water conditioner A Clean line to water conditioner B Iron buildup in water condi tioner B Clean control and add mineral cleaner to mineral bed Increase frequency of regeneration C Inlet of control plugged due to foreign material broken loose from pipes by recent work done on plumbing system C Remo...

Страница 32: ...cycle F Check drive motor and switches 9 Control cycles continuously A Misadjusted broken or shorted switch A Determine if switch or timer is faulty and replace it or replace complete power head 10 Drain flows continuously A Valve is not programming cor rectly A Check control program and positioning of control Replace power head assembly if not positioning properly B Foreign material in control B ...

Страница 33: ...Control Dimensions ...

Страница 34: ...NOTES ...

Отзывы: