Programming
Setting the Time of Day
1. Press and hold either the Up or Down buttons until the programming icon replaces the service icon and the
parameter display reads DO.
2. Adjust the displayed time with the Up and Down buttons.
3. When the desired time is set, press the Extra Cycle button to resume normal operation. The unit will also return to
normal operation after 5 seconds if no buttons are pressed.
Queuing a Regeneration
1. Press the Extra Cycle button and release. The service icon will flash to indicate that regeneration is queued.
2. To cancel a queued regeneration, press the Extra Cycle button and release.
Regenerating Immediately
Press and hold the Extra Cycle button for five seconds.
Entering Master Programming Mode
Set the Time Of Day display to 12:01 P.M. Press the Extra Cycle button (to exit Setting Time of Day mode). Then press
and hold the Up and Down buttons together until the programming icon replaces the service icon and the Display Format
screen appears.
Exiting Master Programming Mode
Press the Extra Cycle button to accept the displayed settings and cycle to the next parameter. Press the Extra Cycle button
at the last parameter to save all settings and return to normal operation. The control will automatically disregard any
programming changes and return to normal operation if it is left in Master Programming mode for 5 minutes without any
keypad input.
Resets
Soft Reset:
Press and hold the Extra Cycle and Down buttons for 25 seconds while in normal Service mode. This resets all
parameters to the system default values, except the volume remaining in meter immediate or meter delayed systems and
days since regeneration in the time clock system.
Master Reset:
Hold the Extra Cycle button while powering up the unit. This resets all of the parameters in the unit. Check
and verify the choices selected in Master Programming Mode.
THE HIGHLIGHTED VALUES ARE THE SELECTIONS THAT SHOULD BE MADE. SOME PARAMETERS WILL REFER
TO THE SETTINGS CHART FOR VALUES.
1. Display Format (Display Code DF)
This is the first screen that appears when entering Master Programming Mode. The Display Format setting specifies the
unit of measure that will be used for volume and how the control will display the Time of Day. This option setting is
identified by “DF” in the upper left hand corner of the screen. There are three possible settings:
Display Format Setting
Unit of Volume
Time Display
GAL
U.S. Gallons
12-Hour AM/PM
Ltr
Liters
24-Hour