10. Fixed Reserve Capacity (Display Code RC)
Press the Extra Cycle button. Use this display to set the Reserve Capacity. This setting specifies a fixed volume that will be held as
a reserve. The reserve capacity cannot be set to a value greater than one-half of the calculated system capacity. The reserve
capacity is a fixed volume and does not change if the unit capacity or feed water hardness is changed. This option setting is
identified by “RC” in the upper left-hand corner of the screen. Use the Up and Down buttons to adjust the value as needed.
Range: 0-half the calculated capacity
WILL NOT BE DISPLAYED WHEN USING SF (SAFETY FACTOR)
11. Day Override (Display Code DO)
Press the Extra Cycle button. Use this display to set the Day Override. This setting specifies the maximum number of days between
regeneration cycles. If the system is set to a timer-type control, the day override setting determines how often the system will
regenerate. A metered system will regenerate regardless of usage if the days since last regeneration cycle equal the day override
setting. Setting the day override value to “OFF” disables this function. This option setting is identified by “DO” in the upper left hand
corner of the screen. Use the Up and Down buttons to adjust the value as needed.
Range: Off-99 days
This will most likely be set at 14 days unless you take vacations lasting more than two weeks. Most households will
eclipse the gallon capacity prior to the override engaging. However, if you are gone for two weeks it is a good idea to
set this at 10 days so it regenerates and is fresh when you return. Water standing in the system for longer than 14 days
can become stagnant.
12. Regeneration Time
Press the Extra Cycle button. Use this display to set the Regeneration Time. This setting specifies the time of day the control will
initiate a delayed, manually queued, or day override triggered regeneration. This option setting is identified by “RT” in the upper left
hand corner of the screen. Use the Up and Down buttons to adjust the value as needed.
This should be set to a time that is about 2 hours after everyone is sleeping in the
home.