US Water Systems 400-USUV-10 Скачать руководство пользователя страница 7

2. 

Select a suitable location for the disinfection system and its related components. As it is recommended to install a 

GFCI, make sure that this is taken into consideration prior to any installation. The system can either be installed verti-
cally (inlet port at the bottom) as shown in Figure 3 A, or horizontally as shown in Figure 3 B. However, the vertical 
installation is the most preferred method. When selecting a mounting location, leave enough space to allow the re-
moval of the UV lamp and/or quartz sleeve (typically leave a space equal to the size of the UV chamber itself). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3. 

Mount the system to the wall using the supplied clamps. Various connection methods can be used to connect the wa-

ter source to the system, however union type connectors are recommended. The use of a flow restrictor device will 
help to maintain the manufacturers rated flow. The flow restrictor should be installed on the outlet port and is de-
signed to be installed in one direction only. Ensure that the flow of the water matches the flow direction as indicated 
on the flow restrictor. Refer to Figure 4. 

Note: 

DO NOT solder connections while attached to the system as this could damage the O

-

ring seals.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4. 

Mount the US WATER SYSTEMS ICE controller horizontally to the wall, near the UV chamber. Ideally place the con-

troller above the chamber and away from any water connection point, to prevent any water from potentially leaking 
onto the controller by means of a leak at a connection point or a “sweating” system. Make sure you allow for a “drip-
loop” as shown in Figure 5 on the UV lamp, UV sensor, and power cord, again, to prevent any water from potentially 
entering the controller. 

Installation 

Figure 4 Flow Restrictor 

M

in

cl

e

a

ra

n

ce

 e

qu

al

 

to

 u

ni

o

ve

ra

ll 

le

n

g

th

 

Uni

o

ve

ra

ll 

le

n

gth

 

Unit overall length 

Min. clearance equal 
to unit overall length 

Figure 3 Disinfection Installation - Vertical and Horizontal 

Outlet port 

on cell 

Flow 

Flow 

Restrictor  

(NSF Products only) 

Flow direction must 

be the same as arrow 

on flow restrictor 

Optional 

by-pass 

assembly 

Optional 

drain 

cock 

Содержание 400-USUV-10

Страница 1: ...ance Class B Powered by US Water Systems Corporate Office 1209 Country Club Road Indianapolis IN 46234 info uswatersystems com www uswatersystems com 1 800 608 8792 Owner s Manual Visit us online at www uswatersystems com REVISION 1 0 REVISION DATE September 29 2015 Models 400 USUV 10 400 USUV 20 400 USUV 30 ...

Страница 2: ...hould US Water Systems replacement lamps be used Use of widely available non genuine replacement lamps has been shown to damage the control module of US Water Systems UV disinfection equipment An increasing number of calls to US Water Systems Technical Support are connected with non genuine lamps being used unknowingly as replacements Damage arising from the use of non genuine lamps poses a safety...

Страница 3: ...d be hot and should not be touched without care This symbol indicates there is a potential for VERY hot water when flow is started This symbol indicates there is Mercury present Hg Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electric shock special care should be taken since water is present near the electrical equipment Unless a situ...

Страница 4: ... heat and sharp edges Always disconnect the extension cord from the receptacle before disconnecting this system from the extension cord Never yank cord to pull plug from outlet Always grasp the plug and pull to disconnect SYSTEM PROTECTION To protect your Controller a UL1449 certified or equivalent transient voltage surge suppressor is strongly recommended The UV lamp in this system conforms to th...

Страница 5: ...nt life 9000 hours S200RL HO 400 USUV 10 S410RL HO 400 USUV 20 S600RL HO 400 USUV 30 4 Retaining Nut RN 001 Used on all systems 5 Controller for 100 240V 50 60HZ models only BA ICE CL 400 USUV 10 400 USUV 20 BA ICE C 400 USUV 30 6 IEC replacement power cords for controller sold separately 260010 400 USUV 10 400 USUV 20 400 USUV 30 7 Mounting Brackets Clamp Assembly 410067 Used on all systems 5 Gen...

Страница 6: ...e exposed to the weather Install the disinfection system on cold water line only before any branched lines A 5 micron sediment filter must precede the disinfection system Ideally the disinfection system should be the last treatment the water receives before it reaches the faucet Procedure 1 Figure 2 shows the installation of a typical disinfection system and the related components that may be used...

Страница 7: ...ned to be installed in one direction only Ensure that the flow of the water matches the flow direction as indicated on the flow restrictor Refer to Figure 4 Note DO NOT solder connections while attached to the system as this could damage the O ring seals 4 Mount the US WATER SYSTEMS ICE controller horizontally to the wall near the UV chamber Ideally place the con troller above the chamber and away...

Страница 8: ...nywhere in the house for a minute to flush out the warm water 3 2 Disinfection Procedure UV disinfection is a physical disinfection process and does not add any potentially harmful chemicals to the water As UV does not provide a disinfection residual it is imperative that the entire distribution system located after the UV be chemi cally disinfected to ensure that the plumbing system is free from ...

Страница 9: ...ment for the UV unit 2 The above disinfection procedure will result in a massive chlorine residual far in excess of the 0 5 to 1 0 mg L typically present in municipally chlorinated water and of a magnitude consistent with the minimum 50 mg L chlorine solution recommended for the disinfection of distribution systems known to be contaminated DO NOT consume water until complete system has been flushe...

Страница 10: ...us operation approximately one year in order to ensure adequate disinfection Procedure 2 3 4 10 MINS 1 2 Shut off the water line to chamber and release system pressure before servicing Disconnect main power source and allow the unit to cool for 10 minutes Remove the lamp connector by squeezing the plastic locking tabs on the side of the connector Remove the lamp in upward direction from the chambe...

Страница 11: ...LR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be cleaned completely or it is scratched or cracked then re place the sleeve Reinstall the quartz sleeve in the chamber allowing the sleeve to protrude an equal distance at both ends of the chamber Slide supplied O rings onto each end of the quartz sleeve Reinstall the top and bottom retaining nuts floating spring a...

Страница 12: ... reset button for 5 seconds which is located on the left side of the controller Each time the timer reset button is pressed the controller alarm is deferred seven days Once the final 7 day de ferral has been reached the alarm can only be silenced by changing the UV lamp and manually resetting the controller tim er refer to Section 4 1 5 1 3 Resetting UV lamp Life Refer to Section 4 1 Note Even tho...

Страница 13: ...urged Unit Leaking Water Problem with O ring seal on retaining nut and or UV sensor Ensure O ring is in place check for cuts or abrasions clean O ring moisten with water lubricant and re install replace if necessary 410867 Condensation on UV chamber caused by excessive humidity cold water Check location of disinfection system and control humidity Inadequate inlet outlet port connec tions Check thr...

Страница 14: ...Specifications Standard and Validated Section 7 Manufacturer s Dose Flow Chart 18 400 USUV 10 400 USUV 20 400 USUV 30 ...

Страница 15: ...3 2 x 2 5 22 3 cm x 8 1 cm x 6 4 cm 8 8 x 3 2 x 2 5 Inlet Outlet Port Size Combo 3 4 FNPT 1 MNPT Combo 3 4 FNPT 1 MNPT 1 MNPT Shipping Weight 5 4 kg 12 lbs 7 7 kg 17 lbs 8 6 kg 19 lbs Electrical Voltage 100 240V 50 60Hz 100 240V 50 60Hz 100 240V 50 60Hz Power Consumption 35 W 60 W 78 W UV Lamp Watts 25 W 46 W 58 W Total Running Time Yes Yes Yes Maximum Operating Pressure 8 62 bar 125 psi 8 62 bar ...

Страница 16: ...g that purchaser uses bulbs and sleeves purchased from US Water During this time US WATER SYSTEMS will repair or replace at its option any defective parts covered by the warranty Please return the defective part to process your claim If this product is used in a commercial application the warranty on the chamber is 10 years One Year Limited Warranty for UV lamps Sleeves and UV Sensors US WATER SYS...

Отзывы: