Always disconnect power before performing any work on the disinfection system.

Always shut-off water flow and release water pressure before servicing.

Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present.

Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection.

Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.

Maintenance 

Section 4 

Maintenance 

4.1  Replacing UV Lamp 

WARNING 

NOTICE 

Reset UV lamp life timer after UV lamp replacement. Refer to

 Section 5.1.3.

 Refer to

 www.lamprecycle.org

 for UV lamp disposal.

DO NOT use water during replacement of UV lamp.

UV lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000 hours 
of continuous operation (approximately one year) in order to ensure adequate disinfection. 

 

Procedure: 

 

10 MINS 

Shut off the water line to 

chamber and release 
system pressure before 
servicing. 

Disconnect main power

source and allow the unit
to cool for 10 minutes.

Remove the lamp connector 

by squeezing the plastic
locking tabs on the side of
the connector.

Remove the lamp in 
upward direction from
the chamber and lamp 
connector base.

Always hold the lamp 
at the ceramic ends.

Insert the new lamp fully into 

the chamber leaving about
two inches of the lamp 
protruding from the chamber. 

Attach the connector to 

the lamp and note that 
the connector will only 
allow correct installation 
in one position. 

Push the lamp connector

against lamp connector 
base together until an audi-
ble click is heard. 

Re-pressurize the system to 

check for leaks. 

Hold down the timer reset
button and reapply power
to the controller until you 
see           , then release 
timer reset button.

A 5 second delay will occur 
until you hear an audible 
tone and the LED display
will read one again           .

10 

Содержание 400-USUV-10

Страница 1: ...ance Class B Powered by US Water Systems Corporate Office 1209 Country Club Road Indianapolis IN 46234 info uswatersystems com www uswatersystems com 1 800 608 8792 Owner s Manual Visit us online at www uswatersystems com REVISION 1 0 REVISION DATE September 29 2015 Models 400 USUV 10 400 USUV 20 400 USUV 30 ...

Страница 2: ...hould US Water Systems replacement lamps be used Use of widely available non genuine replacement lamps has been shown to damage the control module of US Water Systems UV disinfection equipment An increasing number of calls to US Water Systems Technical Support are connected with non genuine lamps being used unknowingly as replacements Damage arising from the use of non genuine lamps poses a safety...

Страница 3: ...d be hot and should not be touched without care This symbol indicates there is a potential for VERY hot water when flow is started This symbol indicates there is Mercury present Hg Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electric shock special care should be taken since water is present near the electrical equipment Unless a situ...

Страница 4: ... heat and sharp edges Always disconnect the extension cord from the receptacle before disconnecting this system from the extension cord Never yank cord to pull plug from outlet Always grasp the plug and pull to disconnect SYSTEM PROTECTION To protect your Controller a UL1449 certified or equivalent transient voltage surge suppressor is strongly recommended The UV lamp in this system conforms to th...

Страница 5: ...nt life 9000 hours S200RL HO 400 USUV 10 S410RL HO 400 USUV 20 S600RL HO 400 USUV 30 4 Retaining Nut RN 001 Used on all systems 5 Controller for 100 240V 50 60HZ models only BA ICE CL 400 USUV 10 400 USUV 20 BA ICE C 400 USUV 30 6 IEC replacement power cords for controller sold separately 260010 400 USUV 10 400 USUV 20 400 USUV 30 7 Mounting Brackets Clamp Assembly 410067 Used on all systems 5 Gen...

Страница 6: ...e exposed to the weather Install the disinfection system on cold water line only before any branched lines A 5 micron sediment filter must precede the disinfection system Ideally the disinfection system should be the last treatment the water receives before it reaches the faucet Procedure 1 Figure 2 shows the installation of a typical disinfection system and the related components that may be used...

Страница 7: ...ned to be installed in one direction only Ensure that the flow of the water matches the flow direction as indicated on the flow restrictor Refer to Figure 4 Note DO NOT solder connections while attached to the system as this could damage the O ring seals 4 Mount the US WATER SYSTEMS ICE controller horizontally to the wall near the UV chamber Ideally place the con troller above the chamber and away...

Страница 8: ...nywhere in the house for a minute to flush out the warm water 3 2 Disinfection Procedure UV disinfection is a physical disinfection process and does not add any potentially harmful chemicals to the water As UV does not provide a disinfection residual it is imperative that the entire distribution system located after the UV be chemi cally disinfected to ensure that the plumbing system is free from ...

Страница 9: ...ment for the UV unit 2 The above disinfection procedure will result in a massive chlorine residual far in excess of the 0 5 to 1 0 mg L typically present in municipally chlorinated water and of a magnitude consistent with the minimum 50 mg L chlorine solution recommended for the disinfection of distribution systems known to be contaminated DO NOT consume water until complete system has been flushe...

Страница 10: ...us operation approximately one year in order to ensure adequate disinfection Procedure 2 3 4 10 MINS 1 2 Shut off the water line to chamber and release system pressure before servicing Disconnect main power source and allow the unit to cool for 10 minutes Remove the lamp connector by squeezing the plastic locking tabs on the side of the connector Remove the lamp in upward direction from the chambe...

Страница 11: ...LR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be cleaned completely or it is scratched or cracked then re place the sleeve Reinstall the quartz sleeve in the chamber allowing the sleeve to protrude an equal distance at both ends of the chamber Slide supplied O rings onto each end of the quartz sleeve Reinstall the top and bottom retaining nuts floating spring a...

Страница 12: ... reset button for 5 seconds which is located on the left side of the controller Each time the timer reset button is pressed the controller alarm is deferred seven days Once the final 7 day de ferral has been reached the alarm can only be silenced by changing the UV lamp and manually resetting the controller tim er refer to Section 4 1 5 1 3 Resetting UV lamp Life Refer to Section 4 1 Note Even tho...

Страница 13: ...urged Unit Leaking Water Problem with O ring seal on retaining nut and or UV sensor Ensure O ring is in place check for cuts or abrasions clean O ring moisten with water lubricant and re install replace if necessary 410867 Condensation on UV chamber caused by excessive humidity cold water Check location of disinfection system and control humidity Inadequate inlet outlet port connec tions Check thr...

Страница 14: ...Specifications Standard and Validated Section 7 Manufacturer s Dose Flow Chart 18 400 USUV 10 400 USUV 20 400 USUV 30 ...

Страница 15: ...3 2 x 2 5 22 3 cm x 8 1 cm x 6 4 cm 8 8 x 3 2 x 2 5 Inlet Outlet Port Size Combo 3 4 FNPT 1 MNPT Combo 3 4 FNPT 1 MNPT 1 MNPT Shipping Weight 5 4 kg 12 lbs 7 7 kg 17 lbs 8 6 kg 19 lbs Electrical Voltage 100 240V 50 60Hz 100 240V 50 60Hz 100 240V 50 60Hz Power Consumption 35 W 60 W 78 W UV Lamp Watts 25 W 46 W 58 W Total Running Time Yes Yes Yes Maximum Operating Pressure 8 62 bar 125 psi 8 62 bar ...

Страница 16: ...g that purchaser uses bulbs and sleeves purchased from US Water During this time US WATER SYSTEMS will repair or replace at its option any defective parts covered by the warranty Please return the defective part to process your claim If this product is used in a commercial application the warranty on the chamber is 10 years One Year Limited Warranty for UV lamps Sleeves and UV Sensors US WATER SYS...

Отзывы: