Descaling instructions boiler / introduction
The boiler must be descaled, at the latest, when the error E05 appears on the display. Be-
cause the hardness of the water varies signi
fi
cantly depending on the location, scheduled
descaling may need to be brought forward if you notice a signi
fi
cant drop in steam emission,
or particles of limescale coming out of the steam accessories.
MAKE SURE THE APPLIANCE HAS COOLED DOWN COMPLETELY
Warning!
Descalers can be harmful. Read the information on the descaler packaging and
follow the safety instructions.
Descalers or vinegar may cause damage to surfaces. Wipe up drops immediately. Only use
suitable and recommended descalers.
Only perform descaling on a cooled appliance.
Recommended descaler:
Entkalkungsanleitung B
You must perform descaling at the latest when the “Probe cap with Clean” symbol appears on the
display. As water quality varies hugely by region, descaling may also be required before this. Check
the probe cap for limescale accordingly. Heavy limescale build-up indicates that descaling is required.
Warning: Only perform probe check on a cooled appliance.
Fig.01
Warning!
Descalers can be harmful. Read the information on the descaler packaging and follow the
safety instructions.
Descalers or vinegar may cause damage to surfaces. Wipe up drops immediately. Only use suitable
and recommended descalers.
Only perform descaling on a cooled appliance.
Recommended descaler:
beam descaler item no.: 8050
Descaling instructions boiler / introduction
Fig. 1
\n\nThe procedure must be
completed completely.
To start the descaling procedure
press the OK button.
ATTENTION!
Descaling procedure
BACK
OK
26
1. Preparation
Boiler descaling / step 1
a)
b)
-
Warning:
Before starting, disconnect from the main power by pulling out oft he
plug.
Remove the sound-proo
fi
ng casing on the un-
derside of the appliance. To remove, loosen
the middle
fi
xing screw by hand, which will en-
able you to fold down, detach and remove the
sound-proo
fi
ng casing.
Place a suitable container under the appliance
and open the drain plug by turning it to the
left with the included Inbus key (label blue ring
“Water Only”).
Drain the reservoir and then screw the drain
plug back in and tighten slightly
(Do not screw
too tight)
.
Содержание BlueEvolution S+
Страница 1: ...1 US STEAM 2440 Chambers Street Ste AVenus Texas 76084 817 297 7745 ussteam net ...
Страница 16: ...16 19 Service Maintenance Part 1 Hot water module descaling ...
Страница 19: ...19 24 Service Maintenance Part 2 Boiler descaling ...
Страница 24: ...24 30 Service Maintenance Part 3 Polyester filter optional water filter and O rings ...