Installation and Debugging 

 

Any erroneous installation, adjustment, refit, overhaul or maintenance may cause 

property damage or personal injury. The work shall be performed by authorized and 

licensed technicians, otherwise the manufacturer has the right to void warranty 

service; 

 

Must be installed in accordance with the local code. If no similar standard, you 

should conform to the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the National Gas 

Installation Code, CSA-B149.1, or the L.P. Gas Installation Code, CSA-B149.2 as 

applicable; 

 

The appliance individual shutoff valve must be disconnected from the gas supply 

piping system during any pressure testing of that system at test pressures in excess of 

1/2psi (3.45kPa). 
 
Unpacking and Installation 

 

Please dispose of all packaging materials and residues after unpacking; 

 

Check the equipment. If it is damaged, please keep wrappers and receipts which 

must be signed by the carrier representative (Driver), and contact the carriers to pursue 

a claim within 15 days after receiving; 

 

Check all accessories complete. Refer to table 4; 

 

Be sure to install supporting legs before using, and do not tear up any label or logo 

before use; 

 

Please read these instructions carefully before installation and operation. Please 

contact your local agent if you have any questions; 

 

The charbroiled shall be installed on a level, solid, non-skid and incombustible 

surface, and placed in a well-lit waterproof work area, and away from children and 

customers; 

 

The installation position is a well-ventilated place in accordance with the local 

regulations; 

The char broiler must be installed under the matched cooking fume exhauster according to 

the local regulations; 

 

Important: 

Installation and ventilation laws, and codes are very different, you 

should state and comply with all codes of the National Fire Protection Association Inc. 

when it comes to requirements for installation of equipment;

 

 

Screw 4 adjustable stainless steel legs in the tapping hole with four corners of the 

char broiler bottom, ensure sufficient space for ventilation; 

 

Adjustable stainless steel legs to make the equipment level, and get the same level 

with other series of the same stove; please lift the equipment rather than

 

drag.

 

Содержание USSP-18-1

Страница 1: ...t Stove Operating Instructions Before you begin please read these instructions carefully to use this product correctly to make the product perform ideally and to avoid hazards Models USSP 18 1 USSP 18 2 USSP 18 1L USSP 18 2L ...

Страница 2: ...manual in a safe place for convenient reference and operation This instruction manual is subject to any change without further notice and the manufacturer reserves the right of final interpretation The appliance is designed for commercial purposes not for household use A statement instructing the purchaser to post in a prominent location instructions to be followed in the event the user smells gas...

Страница 3: ...ion 3 Brief Introduction 3 Manufacturer s Authority and Responsibility 3 Parameter Specifications 4 8 Transport and Storage 8 Installation and Debugging 9 11 Safety Notices and Precautions 11 Operating Instructions 12 14 Cleaning and Maintenance 15 16 Troubleshooting 17 Spare Parts 18 22 Accessories List 23 ...

Страница 4: ...in our company production Which is quality designed reasonably structured conveniently operated durable and conveniently maintained Equipped with a cast iron burner and a high efficiency stainless steel tubular burner and pilot light convenient to ignite the main fire burner This is hotel supermarket western restaurant and food industry s ideal cooking product equipment Manufacture s Authority and...

Страница 5: ... 4 Parameter Specifications Outline Dimensions in USSP 18 1 ...

Страница 6: ... 5 USSP 18 2 ...

Страница 7: ... 6 USSP 18 1L ...

Страница 8: ... 7 USSP 18 2L ...

Страница 9: ... ATSP 18 2 2 sets Independent control Natural Gas 4 80 000 160 000 32 L P Gas 10 80 000 160 000 49 ATSP 18 1L 1 set Independent control Natural Gas 4 80 000 80 000 32 L P Gas 10 80 000 80 000 49 ATSP 18 2L 2 sets Independent control Natural Gas 4 80 000 160 000 32 L P Gas 10 80 000 160 000 49 Transport and Storage During transportation handle carefully and keep upright to prevent damage of the pro...

Страница 10: ...ter receiving Check all accessories complete Refer to table 4 Be sure to install supporting legs before using and do not tear up any label or logo before use Please read these instructions carefully before installation and operation Please contact your local agent if you have any questions The charbroiled shall be installed on a level solid non skid and incombustible surface and placed in a well l...

Страница 11: ...soap water or testing instrument to test whether piping joint leaks or not before using and forbid using an open flame to test After installing completely you should check gas supply pressure Use a pressure gauge which is equipped with liquid such as U type pressure gauge the minimum value is 0 1mbar or a digital pressure gauge to test Steps are as follows Remove top panel and needle type pressure...

Страница 12: ...lways be followed including the following The Heavy Duty Stock Pot Stove burners cooking grates and outside surfaces will be hot to touch during and after use Turn off the equipment when repairing maintaining and cleaning If the equipment has any problems of equipment damage gas piping leaks igniter or valves damage or lose product accessories do not operate and call for service immediately The us...

Страница 13: ...n use a screwdriver to adjust the height of the flame Fig 3 Igniting the main burner Revolve the main fire control valve knob anticlockwise after lighting the pilot light the main fire burner is lighted by the pilot light The power of burner increases as the revolving angel increases When knob reaches to burner is in the maximum power Fig 4 Fig 2 Fig 3 Fig 4 ATSP 18 1 CONTROL PANEL ATSP 18 2 CONTR...

Страница 14: ... 20 minutes before broiling for preheating according to the cooking requirement to adjust the flame size Notice When first preheating the furnace will smoke above This is caused by protective lipids on the grates and other parts are heated it is normal and it will be eliminated after the power up to the maximum for burning an hour Exchange main fire nozzle to switch gas source Remove control panel...

Страница 15: ... opening degree Then screw damper solid screw make sure the equipment will not get loose in the process of moving and transition Reinstall control panel Caution Each burner damper has been adjusted before delivery once air input Normal use without adjustment but only switching gas Adjust only by authorized and licensed technicians Fig 7 Fig 8 Fig 9 ...

Страница 16: ...Wait for the equipment to cool down after the unit has been turned off before cleaning Cut off the gas source when not in use If the equipment is not used for a long time clean the surface by wiping it with a soft cloth and place it in a well ventilated area Comprehensively check the equipment at least once every year by authorized and licensed technicians The product is made of 90 metals and cann...

Страница 17: ...ff valves when not in use Wipe panel and control valve knob with mild detergent daily Catch tray Pull out catch tray from front body until the equipment cools down Use a cloth with cleaning agent to wipe unit surface wipe up residue Reinstall after cleaning Warning if the catch tray is permitted to fill too high should be cleaned Per use ...

Страница 18: ...rd a sound of fire 1 Insufficient gas pressure in pipe 1 Contact the local gas supply dept 2 Not match nozzle aperture with gas resources 2 Adjust nozzle diameter 3 Flow of connection pipe is not enough 3 Increase pipe s allowable flow 4 Damper opening degree is too large 4 Adjust damper Yellow flame and black smoke 1 Use bottom gas 1 Change gas 2 Not match nozzle aperture with gas resources 2 Adj...

Страница 19: ...other companies our company has the right not to provide warranty service Order replacement parts from authorized representatives and after sale service agency Provide the model number serial number and description when you order components Fig 10 ...

Страница 20: ...1L 6 USSP 18 2L 3 21206001002 Control panel 1 453 155 USSP 18 1 21206002002 USSP 18 2 21206001002 USSP 18 1L 21206002002 USSP 18 2L 4 301081006 Galvanized American outside six corner with pad tapping 6 ST4 8 12 5 USSP 18 1 8 USSP 18 2 6 USSP 18 1L 8 USSP 18 2L 5 21106001010 Catch tray 1 460 365 13 USSP 18 1 21106002012 990 365 13 USSP 18 2 21106001010 460 365 13 USSP 18 1L 21106002012 990 365 13 U...

Страница 21: ...her 2 Φ6 5 Φ18 USSP 18 1 2 1L 2L 12 301030002 A18 stopcock 2 A18 318 USSP 18 1 4 USSP 18 2 2 USSP 18 1L 4 USSP 18 2L 13 301040012 A18 nozzle NG32 2 USSP 18 1 301040013 A18 nozzle LP49 4 USSP 18 2 301040012 A18 nozzle NG32 2 USSP 18 1L 301040013 A18 nozzle LP49 4 USSP 18 2L 14 301990006 Damper cover 2 USSP 18 1 4 USSP 18 2 2 USSP 18 1L 4 USSP 18 2L 15 301081011 Stainless steel cross screws 2 M5 10 ...

Страница 22: ...SP 18 1 4 USSP 18 2 2 USSP 18 1L 4 USSP 18 2L 21 211060001011 Pilot light head stator 2 USSP 18 1 4 USSP 18 2 2 USSP 18 1L 4 USSP 18 2L 22 21106002014 Front burner inner pilot intake tube 1 Φ4 7 0 6 USSP 18 1 2 1L 2L 23 301080008 Brass lock nut 0 M18 USSP 18 1 2 USSP 18 2 0 USSP 18 1L 2 USSP 18 2L 24 301050014 Brass double male elbow 0 M16 turn to 3 8 27UNS USSP 18 1 2 USSP 18 2 0 USSP 18 1L 2 USS...

Страница 23: ... 2 1 USSP 18 1L 2 USSP 18 2L 30 301010013 Boiler burner 1 Φ305 385 USSP 18 1 2 USSP 18 2 1 USSP 18 1L 2 USSP 18 2L 31 301070014 18 single head broiler in take tube 1 343 523 86 USSP 18 1 301070015 18 double head broiler in take tube 343 1053 86 USSP 18 2 301070014 18 single head broiler in take tube 343 523 86 USSP 18 1L 301070015 18 double head broiler in take tube 343 1053 86 USSP 18 2L 32 30108...

Страница 24: ...re interface tightness 2 The pressure regulator s have connected the maximum load of natural gas cannot exceed 6 and of LP cannot exceed 12 3 Adjustment range of the pressure regulator s is 4 6 for natural gas and 7 10 for L P 4 Screw the hex nut Fig 11 before connect air intake ensure gas mark Fig 12 on the plastic core whether match with connected gas source if not then pull out the plastic core...

Страница 25: ... durability and low maintenance charge But to update some components and necessary maintenance can prolong life length of the products Contact the dealer for assistance In order to avoid confusion please follow the format in figure 10 and table 4 ...