background image

16

FILLING PROCEDURES:
1. Unscrew and remove the oil fill plug.
2. Fill the crankcase with lubricant.
3. Replace the oil fill plug HAND TIGHT ONLY.

 CAUTION:  Do not re-

move the oil fill plug while 
the compressor is running.
Refer to the following ta-
ble for crankcase capacity. 
Use one of the following 
methods illustrated to de-
termine when the crank-
case is full.

OPERATION INSTRUCTIONS

PRE-START ROUTINE

1. Ensure that the location for the compressor 
is clean, dry and well ventilated.
2. Ensure the crank case has been filled with oil and 
is at the correct level, and the air filter has been 
fitted.
For the first time of operation, run the com-
pressor for 10 minutes with no load and with 
the outlet valve open to ensure all parts are 
well lubricated.

 WARNING: Be aware that pressurised air will 

be discharged from the outlet and care should 
be taken that this discharge is not directed 
towards you the operator, or other persons 
within the area.

TO START & STOP THE COMPRESSOR
1. Check the rating label on 
the compressor indicates   
120 V.
2. Plug in the mains cable of 
the compressor to a stand-
ard 120 V household power 
point and turn on.
3. To start the compressor, 
lift the ON/OFF switch on the 
pressure switch cover (Fig. 4).
4. To stop the compressor, 
push the ON/OFF switch 
down (Fig. 5).

OPERATION

1. The pressure in the tank is controlled by the 
action of the pressure switch located under  
the pressure switch cover. When the set maxi-

mum pressure is reached the pressure switch 
activates and the motor is switched off. 
The pressure then decreases as the air is used 
by the connected tool until the set minimum 
pressure is reached after which the pressure 
switch causes the motor to switch on again.
The operator of the compressor should be well 
aware that during use of the compressor the 
motor will start and stop under the influence 
of the rising or falling pressure in the tank. The 
motor will start without any warning. 
2. The maximum and minimum pressures are 
factory set and the operator should not try to 
change them.
3. The outlet on the compressor can be regu-
lated.
4. The pressure of the air 
outlet can be changed, 
by turning the regulating 
knob (Fig. 6). Rotate the 
knob clockwise to increase 
pressure and anti-clock-
wise to decrease pressure.
NOTE: To obtain the correct output reading 
on the regulated output gauge, the air must 
be flowing through the outlet. The regulating 
valve should be adjusted and the gauge read 
with the outlet valve open and the air being 
discharged from the regulated outlet through 
the accessory being used. To increase the air 
pressure, rotate the regulating valve clockwise. 
To decrease the pressure, rotate the regulating 
valve anti-clockwise.
NOTE: If you do not allow the air to discharge 
while you are setting the regulator, the pres-
sure as indicated on the regulated outlet 
gauge will be incorrect. This gauge ONLY in-
dicates the correct pressure while air is being 
discharged from the outlet.
5. On completion of the task, i.e. when you 
have finished using the compressor, or when 
you are leaving the compressor unattended, 
turn off the compressor in the following way:
• Press down the on/off switch.
• Wait for the pressurised air to bleed from the 
release valve under the pressure switch cover.
NOTE: When you press the button down you 
should hear a short air discharge (Approx. 1/2 
second).
• Switch off the electrical power supply and re-
move the electrical plug.

ON

OFF

Fig.4

Fig.5

Over-

filled

Optimal 

quantity 

Fig.6

COMP8115 manual.indd   16

30/11/15   5:13 p.m.

Содержание COMP8115

Страница 1: ...s de operar esta herramienta WARNING Read understand and follow the safety rules in this manual before operating this tool Compresor de Aire Industrial Vertical Vertical Air Compressor COMP8115 Manual...

Страница 2: ...les for air compressors Features Installation operation Maintenance Troubleshooting Air compressor Technical data Warranty policy Normas generales de seguridad Seguridad el ctrica Seguridad personal U...

Страница 3: ...rramientas el ctricas a la llu via o a condiciones de humedad El agua que entre en la herramienta aumentar el riesgo de choque el ctrico No abuse del cable No usar nunca el cable para llevar levantar...

Страница 4: ...cidas o carez can de experiencia o conocimiento a menos que dichas personas reciban una supervisi n o capacitaci n para el funcionamiento del apa rato por una persona responsable de su segu ridad Los...

Страница 5: ...s lejos posible del rea de aplicaci n Nunca opere una soldadora cerca del com presor No intente soldar alguna parte al tan que ya que esto podr a ocasionar que el metal y la estructura del tanque se d...

Страница 6: ...lizan orejeras efectivas Da o a los ojos si no se usan gafas de seguri dad eficaces Nunca aplique el aire de este compresor di rectamente a cualquier parte de una persona o de su cuerpo No intente obs...

Страница 7: ...de va a ser ubi cado el compresor se encuentra limpia seca y bien ventilada 2 Encienda el compresor siguiendo los pasos que m s adelante se muestran en la secci n de Encendiendo y apagando el compreso...

Страница 8: ...rese que todo el aire presu rizado se libere del tanque o abra la v lvula de libera ci n que se encuentra en la parte inferior del tanque MANTENIMIENTO ADVERTENCIA Es recomendable que todas las repara...

Страница 9: ...mento de su instalaci n TENSADO DE CORREAS Se puede lograr el tensado de la correa aflojan do los tornillos de anclaje del motor alejando el motor de la bomba y volviendo a apretar los tornillos de an...

Страница 10: ...ble de alimentaci n est n dar El voltaje es muy bajo Revise el voltaje La temperatura del ambiente es muy bajo Uti lice el calentador o cambie el aceite El fusible es muy peque o Revise el fusible El...

Страница 11: ...al ensamblada Cambie la direcci n de la v lvula EL AIRE DEL COMPRESOR NO PARA Problemas en el interruptor del aire Cambie el interruptor y det ngalo a 8 bares y rein cielo a 5 5 bar Los requisitos del...

Страница 12: ...e damaged cords immediately The use of damaged cords can shock burn or electric shock If an extension cord is necessary a cord with adequate size conductors should be used to prevent excessive voltage...

Страница 13: ...o use a safety device suit able such a thermal and differential switch when you are using an electric equipment SERVICE Tool service must be performed only by quali fied repair personnel Service or ma...

Страница 14: ...xtension cord with this product Use additional air hose instead of an extension cord to prevent power loss and pos sible damage to the motor Use of an extension cord voids the warranty After long work...

Страница 15: ...MBLY ADJUSTMENTS HANDLE The handle must be fitted in the following manner 1 Loosen the screws in each of the handle fix ing tubes using an hex key not included 2 Insert the two ends of the handle into...

Страница 16: ...ssure switch causes the motor to switch on again The operator of the compressor should be well aware that during use of the compressor the motor will start and stop under the influence of the rising o...

Страница 17: ...roleum lubricant while crankcase is warm Drain compressor oil and clean oil sight glass 6 months 1000 hrs of operation Replace oil filter and change lubricant if nec essary on pressure lubricated mode...

Страница 18: ...ife is difficult to predict therefore URREA recommends that you schedule a certified tank inspection within the first five years of compressor service To ar range a tank inspection contact your closes...

Страница 19: ...too loose Switch off the ma chine and tighten the screw Piston heat the valve plates Open the cylinder head and inspect Pistons and valve plates have too much dust Open the cylinder and clean it The b...

Страница 20: ...dified by unauthorized or unqualified person Urrea Herramientas Profesionales S A de C V garantiza este producto por el termino de 1 a o en sus piezas componentes y mano de obra con tra cualquier defe...

Отзывы: