![urmet domus Note 2 1723 Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/urmet-domus/note-2-1723-series/note-2-1723-series_configuration-booklet_1062627016.webp)
16
DS1723-024
INSTALLATION ON TWO-FAMILY KIT REF. 1723/72
On each letterbox, of both apartments (0,1) position two magnetic contacts near the front
fl
ap (mail introduction
fl
ap) and at the back (mail collection door).
Apartment
number
Description of the magnetic contact
function
Connection of the magnetic contact to
the E4BPP(X) transmitter on the wires:
0
Mail introduction slot
Green - White
Mail collection door
Brown - White
1
Mail introduction slot
Purple - White
Mail collection door
Grey - White
On the control panel of the kit, connect a Yokis REL1C relay to the SP terminals and an appropriately powered
receiver MTR2000ERP(X) to the relay.
Follow the directions in the following diagram.
Power supply
230 Vac
Relè (*)
REL1C
MTR2000ERP(X)
receiver
E2BPP(X)
transmitter
(#)
E4BPP(X)
transmitter
(#)
LETTER BOX
APT0
LETTER BOX
APT1
10 m
Panel
Brown
Brown
Brown
Purple
Purple
Grey
White
White
White
Green
(#) A single E4BPP(X) transmitter can be used if the two letterboxes are close (distance of less than 10 m)
(*) WARNING.
THE USE OF THE REL1C RELAY IS MANDATORY. IT ENSURES THE INSULATION
BETWEEN THE LOW WORKING VOLTAGE OF THE KIT AND THE 230Vac VOLTAGE AT
WHICH THE MTR2000ERP(X) RELAY IS POWERED.
FAILURE TO USE THE REL1C RELAY WILL INVALIDATE ALL WARRANTIES.
Con
fi
gure the devices as shown in the next chapter.
CONFIGURATION
The con
fi
guration requires three steps:
STEP 1: CONNECT THE TRANSMITTER TO THE RECEIVER
Using a temporary button in parallel to one of the magnetic contacts, press the button on the transmitter
E5
fi
ve
times in rapid sequence.
Then, while the LED is blinking, press “Connect” on the receiver
R1
.
Содержание Note 2 1723 Series