DS1723-024

Whether to send power to the motion sensors, if this installation diagram is chosen

(8)

:

Enable only in presence of motion sensors.

Whether to associate a video recording in case of alarm or not:

Video recording can be enabled or not.
A delay can be de

fi

 ned between the time in which the alarm was signal and the beginning of the video 

recording.
The camera to use

(9)

 for recording the video clip can be de

fi

 ned. 

The encoding to use is:

1: door panel camera.
2: second panel camera (if present).
3,4,5,6: cameras connected to the CCTV interface Ref. 1723/69.

The duration of the video clips recorded in case of alarm.

 

 





(8)

   The use of motion sensor precludes the possibility of connecting a local camera to the video door phone: the 

two functions are mutually exclusive.

(9) 

ONLY the cameras previously set in the video surveillance con

fi

 guration will be presented as selectable. The 

local camera can not be used for this function.

Содержание Note 2 1723 Series

Страница 1: ...DS 1723 024 LBT 20469 Mod 1723 ONE AND TWO HOUSEHOLD KIT WITH PANEL AND COLOUR 7 HANDS FREE MONITOR Ref 1723 71 1723 72 CONFIGURATION BOOKLET IP45 IK07 IP45 IK07...

Страница 2: ...F THE THERMOSTAT TO THE BOILER 17 WIRED CONNECTION OF THE THERMOSTAT TO THE BOILER 17 ENDING CONFIGURATION 18 OFFICE WITH ATTACHED HOME SETTING 19 AUTOMATIC DOOR OPENER SETTING 20 TEST 22 VIDEO DOOR P...

Страница 3: ...he clock icon in the bottom right to open the following window 1 When entering date and time always clear the contents of the field FIRST and THEN enter the new required value Tap on the required fiel...

Страница 4: ...a weak one provides a minimum level of protection from actions that the end user could change unintentionally WARNING After having entered the password the Installer menu can be accessed even multiple...

Страница 5: ...art of the gate by pressing and open the second only by pressing In this case Check that dip switch 5 is in the OFF position default Connect the terminals SE and SE timed capacitive discharge to a dec...

Страница 6: ...hen controlling the camera Finally tap on the icon on the top right you can assign specific names to the various controlled cameras The set names will appear superimposed on the image during the contr...

Страница 7: ...t the buttons to the devices The last item can be used to reset radio access points BUTTON CONFIGURATION Select this item to open the complete page of all available buttons regardless of their future...

Страница 8: ...uttons it consists of in sequence As in other kits by tapping on a composite button you can set The name of the button The list of Yokis buttons which are part of the composition The delay in the sequ...

Страница 9: ...useful to make only the configured home automation buttons i e only those which generate an action visible to the final user The installer can therefore access to the specific configuration item in ho...

Страница 10: ...g page Tap on the icon you want to associate with the Stairs Light button 4 If you want to delete an association tap on the highlighted icon so that no icons are selected IMPORTING YOKIS BUTTONS FROM...

Страница 11: ...l the access points of all buttons of the video door phone Run M 24 SETTING THE ALARM FUNCTION The alarm function can be set to Detect the opening of a door e g the front door Detect the energising of...

Страница 12: ...sed during the exit time Entrance time with the alarm armed the energising of the sensor will generate an alarm only after the entrance time To which devices to send an alarm signal Enabling the alarm...

Страница 13: ...camera to use 9 for recording the video clip can be defined The encoding to use is 1 door panel camera 2 second panel camera if present 3 4 5 6 cameras connected to the CCTV interface Ref 1723 69 The...

Страница 14: ...tacts can be modified In the Configuration menu which can be opened using the icon on the top right select the Installer menu type in the password 1937 and select Relay Contacts and select one of the...

Страница 15: ...owing diagram Power supply 230 Vac Relay REL1C MTR2000ERP X receiver E2BPP X transmitter LETTER BOX APT0 10 m Panel Brown Brown Brown Purple White White Green WARNING THE USE OF THE REL1C RELAY IS MAN...

Страница 16: ...ply 230 Vac Rel REL1C MTR2000ERP X receiver E2BPP X transmitter E4BPP X transmitter LETTER BOX APT0 LETTER BOX APT1 10 m Panel Brown Brown Brown Purple Purple Grey White White White Green A single E4B...

Страница 17: ...ESS CONNECTION OF THE THERMOSTAT TO THE BOILER Position Yokis MTR2000ERP relay near the boiler Choose two home automation buttons which will be used exclusively for controlling the relay connected to...

Страница 18: ...f the thermostat to the boiler can be defined as follows IF Contact 2 was assigned to the Thermostat function then Contact 2 will automatically appear on this line and there will be nothing to do the...

Страница 19: ...ly from home or no Importantly the kit provides the possibility of controlling two doors in different manner and so button can be programmed to open the office door by doing so you can use the automat...

Страница 20: ...ration menu In the Configuration menu which can be opened using the icon on the top right select the Installer menu type in the password 1937 tap on the arrow button on the bottom and then select Auto...

Страница 21: ...21 DS1723 024 Remove the tick from the Auto Door Opening option In this way the button will no longer be visible on the Home Page...

Страница 22: ...o be easily located the button When the door opens the icon will light up on the panel It is also possible to switch on the stairs or garden light using button or to open the garage door using the but...

Страница 23: ...will appear using the last chosen video format To cycle the other cameras in the system using the side arrows You must return to the camera of the panel to answer To record a video clip of the visito...

Страница 24: ...door phone by tapping on the screen or the button Tap on the camera control button The video door phone will show the image from the panel camera also providing the possibility to open the door or sta...

Страница 25: ...right flashes during the possible output time any alarms during Exit Time will have no effect and turns green fixed to its end to indicate successful activation The video door phone display will switc...

Страница 26: ...isarmed during the entry time 16 by tapping on the icon to clear the tick HOW TO BROWSE VIDEO CLIPS All recorded video clips automatically in case of alarm or voice mail or manually in case of recordi...

Страница 27: ...orded by additional camera The video clip name always comprises the number of the camera which recorded it 1 to 6 the name of the camera customisable during installation the date the time suffix _AL i...

Страница 28: ...using the middle button and insert a microSD card 18 Switch the video door phone back on and first tap the icon and then the Alarms tab A list of the most recent detected alarms will appear with the i...

Страница 29: ...n from the letterbox by opening the rear collection door and check that the LED goes out WARNING If you want to repeat the test on the same letterbox wait for 10 seconds after closing of the rear coll...

Страница 30: ...he call was sent The following appears on the video door phones in the home and in the office PANEL 1 0 PANEL 1 0 All the call related functions will be available in standard configuration See the VID...

Страница 31: ...o the video door phone 4 Switch on the display if it is off by pressing the central button 5 Hold the button pressed until the video door phone reboots 6 Wait for the update to end the operation may t...

Страница 32: ...nd the electric lock is not activated KEY MEMORISATION PROCEDURE Only keys memorised can activate the electric lock connected to the call station To memorise the keys 1 Move the master key close to th...

Страница 33: ...he call station 2 The call station emits a confirmation beep 3 Hold the Master key in front of icon for at least 5 seconds 4 The call station emits a long confirmation beep Remove the key immediately...

Страница 34: ...is buttons During this step you will need to press the Connect button on several receivers Each Yokis button can be configured to control a single activation module or multiple modules Scenario or Cen...

Страница 35: ...35 DS1723 024 Select Configure Buttons to go to the following page The Yokis buttons are the first 8 on top Tap on the Yokis button you want to configure Five items will appear...

Страница 36: ...figuration presses The green LED on the video door phone corresponds to the red LED of a Yokis remote control the notification flashes can be seen on it The expected number of flashes is shown on the...

Страница 37: ...Access Point E7 R1 This is useful for controlling a specific remote receiver or also more than one positioned on Bus Radio For more information see E Range Extension with Radio Bus and E 1 Definition...

Страница 38: ...Mode for controlling up to four receivers On a video door phone instead is often useful to use the buttons in centralised mode e g to have a button which closes all the shutters another one which turn...

Страница 39: ...is advisable to select the Off Up Stop function see previous paragraph switch off the lights and closing the shutters Not Home scenario If you wish to perform various functions at the same time such...

Страница 40: ...he mode to timer mode and wait for 7 flashes on the receiver Send 26 E 26 to configure the time in minutes and wait for 6 flashes on the receiver Send 14 E14 to set the timer to 15 minutes and wait fo...

Страница 41: ...Yokis buttons on the video door phone but not their labels On the Home Page of the video door phone press the Configuration icon select the Installer button enter the password 1937 and then select the...

Страница 42: ...t this point you can Import the NAME of the button the one that the user will see by tapping on the displayed menu item Check correct operation of the button by pressing the Test button It is not poss...

Страница 43: ...o control the centralised locking of all the shutters Close All in Radio Bus mode and a second Yokis button to switch on the lights in the living room and kitchen Living Room and Kitchen Lights On in...

Страница 44: ...ollowing page The composite buttons are characterised by the default name COMP BTN N and are located in the third and fourth row the two on the left There are six in total Tap on the composite button...

Страница 45: ...ose desired at least 2 Delay Between Buttons The following page will appear Here you can choose a waiting time between the functions of the single buttons forming the composite For example if the comp...

Страница 46: ...46 DS1723 024 The order with which the selected buttons will be activated in sequence from the first to the last or from the last to the first...

Страница 47: ...47 DS1723 024...

Страница 48: ...T 20469 Area tecnica servizio clienti 39 011 23 39 810 http www urmet com e mail info urmet com MADE IN CHINA URMET S p A 10154 TORINO ITALY VIA BOLOGNA 188 C Telef 39 011 24 00 000 RIC AUT Fax 39 011...