EASIVOICE SYSTEM

ELECTRONIC INTERCOM SYSTEM

−−−− 

sec.2

EASIVOICE

DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

Mod. 926

ELECTRONIC INTERCOM SYSTEM Mod. 926

PROGRAMMING - INSTALLATION

CONFERENCE CALL

The conference function can connect up to four different users in one 
phonic communication. Only the intercom which made the fi rst call 
can call other intercom in the course of a conversation. In order to 
include another intercom in the conversation, simply dial the extension 
number. One of the following situations will occur:

• 

The intercom door phone called is free: when the handset is lifted, 
the called party will be included in the conversation in course.

• 

The intercom door phone is free: if the handset is not lifted within 30 
seconds, the call will not go through.

• 

The intercom door phone called is engaged: there will be a busy 
tone of a short duration.

FOLLOW-ME

This function allows incoming calls to be routed to another intercom. 
Up to a maximum of eight other intercoms can be routed to one 
intercom. Several consecutive reroutings of calls from one intercom 
can be made to several different intercoms.

How to forward calls from one intercom door phone to another

• 

Go to the other intercom door phone.

• 

Lift the handset of the other intercom.

• 

Press the dedicated “F” key and dial the number of your intercom 
door phone.

• 

Listen for the tone on the handset; one of the following two situations 
will take place:

 • 

Dial tone: the operation was successful 

 hang up.

 • 

Busy tone: calls cannot be routed because calls to 8 other 
intercoms have already been forwarded to that intercom 

 hang 

up.

How to reset your intercom door phone

• 

Return to your intercom.

• 

Lift the handset.

• 

Press the dedicated “F” key and dial your own number. 

• 

Hang up.

Secretary function
This function permits the user to route his own incoming calls to 
another intercom (i.e. the secretary one). All his own incoming calls 
are routed to the secretary intercom EXCEPT the call that arrives 
from the same secretary. In this way the secretary can, if needed, 
“announce” the calls; anyway it cannot “transfer” the call. The routed 
set can always make outgoing calls (and then it can call again the 
person “announced” by the secretary). This function can be carried 
out by modifying the “follow me” as regard to the last paragraph (the 
crossed one).

GENERAL CALLS (only from authorized intercom 
door phone)

A general call can be made through a loudspeaker connected to a 
suitable amplifi er.
The general call can take place at the same time as four other 
conversations, without interfering with them. General call can only be 
made from intercoms which were explicitly defi ned for making such 
calls during the programming phase.
To make a general call: 

• 

Lift the handset.

• 

Dial the special “99” number.

• 

Wait for the “ding-dong” to be generated.

• 

Make the announcement.

• 

Redial the special “99” number.

• 

Hang up.

ANSWERING A CALL FROM THE OUTDOOR 
STATION

This feature is only available on Ref. 926/2 intercom door phone.
A call from the outdoor station produces a different acoustic signal 
from the normal one and can be easily recognized. Lift the handset to 
establish communication; the open-door key can be used to operate 
the electric lock at any point. 

When a user, engaged in conversation with the outdoor station, 
receives a call from the inside, he visualize the call on the led without 
the possibility to be interrupted (not even with the clearing the line 
function).
Vice versa, when a user, engaged in conversation with another internal 
user, receives a call from an outdoor station, he will see the blinking 
led up to the call key is pressed and he will hear an acoustic signal that 
indicates the call with more emphasis.

PROGRAMMING

All the intercom door phones are produced and tested by URMET 
DOMUS. They are all programmed with the following values during the 
testing phase:

• 

Number: 98

• 

General call function disabled: 0

• 

Line clearing disabled: 0

The devices must all be programmed with two digits, e.g. from 01 to 
09, from 10 to 19, from 20 to 25, or with any other number from 01 to 
97.

These values can be changed at any time through the keypad by 
following the procedure described below:

• 

Simultaneously press the “R” and the “F” keys for two seconds. If 
one or two “beeps” are heard while the keys are pressed, it means 
that the two keys were not pressed simultaneously 

 repeat the 

operation.

• 

When the led is lit and a brief acoustic tone is heard, release the two 
keys.

• 

Enter the number to be assigned to the intercom.

• 

The led will go off for a short interval and then go on again, 
coinciding with a brief acoustic tone.

• 

Set authorization (1) or disable (0) for the general call function.

• 

The led will go off for a short interval and then go on again, 
coinciding with a brief acoustic tone.

• 

Set authorization (1) or disable (0) for the line clearing function.

• 

The led goes off defi nitively, coinciding with a brief acoustic tone.

If the procedure described above is not completed within 30 seconds, 
the intercom will return to normal operating conditions, without storing 
the setting that were entered. 

INSTALLATION

WIRES LAYING

All system intercom door phones must be interconnected in parallel 
using 9 wires (or 8 if the general call installation is not provided for). 
These wires have the following functions:

• 

1 for the power supply voltage  

+ 12

• 

1 for the logical ground  

ML

• 

1 for the data line  

D

• 

4 for the 4 phonic lines  

L1, L2, L3, L4

• 

1 for the general call phonic line (this wire can be

  omitted on installations where this feature is not required)  

L5

• 

1 for the phonic ground  

MF

In addition, installations connected to a Call Station must be considered 
4+N additional wires, which increase the number of wires to the 
installation to 13+N (where N depends on the number of call keys used 
– usually 1 or 2).
These 4+N wires are used as follows: 

• 

3 for the talk volume (F1, F2 and ground).

• 

1 for the door-opener.

• 

N for the call.

If the GENERAL call amplifi er is not used do not connect the wire L5.

The maximum distance between the power supply and the furthest 
intercom must be less than 200 meters.
The maximum distance between two intercom door phones to ensure 
a relatively low cross-talk effect is 200 meters. The cross-talk effect 
increases progressively with an increase in distance.
It is therefore advisable to avoid unnecessary connections distances.

EASIVOICE

Содержание EASIVOICE 926

Страница 1: ...sec 2 1 EASIVOICE BASIC DIAGRAMS EASIVOICE SYSTEM DOOR PHONE VIDEO DOOR PHONE SYSTEMS Installation Diagrams EASIVOICE SYSTEM SECTION 2 REV A Download from www urmetdomus com Technical Manuals area...

Страница 2: ...ns with two or more call keys 2 7 BASIC SYSTEM DIAGRAMS INTERCOM CONNECTION OF MAXIMUM 25 INTERCOM DOOR PHONES Possibility of general call service by means of loudspeakers SC101 0313E 2 8 INTERCOM CON...

Страница 3: ...incoming calls from an intercom x to a y one Anyway y can call x and the last one can make outgoing calls Paging function carried out by means of a 5th independent and dedicated line connected to a l...

Страница 4: ...onnect the system wires to the correspondent terminals of the terminal board The connection cable wires to the door phone socket wire are very specific for table installations They must be connected t...

Страница 5: ...nversation cannot last longer than 10 minutes in order to allow other users access to the phone lines Once this time has lapsed an acoustic end of conversation warning signal will be sent to both inte...

Страница 6: ...and can be easily recognized Lift the handset to establish communication the open door key can be used to operate the electric lock at any point When a user engaged in conversation with the outdoor st...

Страница 7: ...can be opened at any time by pressing the door opener key INSTALLATIONS WITH ONE CALL KEY A basic installation is one in which several intercoms type 926 2 are connected to a Call Station and can all...

Страница 8: ...and be connected to it with a shielded cable The power supply Ref 926 3 is sized for an average installation of 25 intercoms A larger number of intercoms will require additional power supplies connec...

Страница 9: ...on Diagrams COLLEGAMENTO INTERCOMUNICANTE DI UN MASSIMO DI INTERCOM CONNECTION OF MAXIMUM 25 INTERCOM DOOR PHONES Possibility of general call service by means of loudspeakers CY 002 VX 008 CY 004 ELEC...

Страница 10: ...be connected to it with a shielded cable The power supply Ref 926 3 is sized for an average installation of 25 intercoms A larger number of intercoms will require additional power supplies connected...

Страница 11: ...DOOR PHONES Possibility of general call service by means of loudspeakers VX 008 CY 002 VX 008 CY 002 VX 008 CY 002 VX 008 CY 002 CY 004 ELECTRONIC INTERCOM SETS Mod 926 IV GROUP OF 22 SETS III GROUP O...

Страница 12: ...blems no more than 16 intercoms can be called in parallel It is recommended that the power supply Ref 926 3 be placed at the center of the installation to minimize the cross talk effect EQUIPMENT For...

Страница 13: ...or station All the intercom door phones are called in parallel from the outdoor station L5 L4 L3 L2 L1 ML 12 D MF L5 L4 L3 L2 L1 ML 12 D MF A CA 1 AP A 2 L5 L4 L3 L2 L1 ML 12 D MF CA 1 AP 2 CY 002 CY...

Страница 14: ...s no more than 16 intercoms can be called in parallel It is recommended that the power supply Ref 926 3 be placed at the center of the installation to minimize the cross talk effect EQUIPMENT For said...

Страница 15: ...r station is equipped with two keys with one of them it calls in parallel the 8 intercoms of group I with the second one those of group II L5 L4 L3 L2 L1 ML 12 D MF L5 L4 L3 L2 L1 ML 12 D MF A CA 1 AP...

Страница 16: ...alk effect EQUIPMENT For said installation Scheme SC101 0382F the following N 16 Intercom door phones Ref 926 2 N 1 Power supply Ref 926 3 N 1 Power supply for door phone system 28VA Ref 786 11 28VA R...

Страница 17: ...tion Possibility of paging service by means of loudspeakers L5 L4 L3 L2 L1 ML 12 D MF CA 1 AP CY 003 2 L5 L4 L3 L2 L1 ML 12 D MF CA 1 AP 2 CY 004 L5 L4 L3 L2 L1 ML 12 D MF CY 002 A A C4 007 C4 008 L U...

Страница 18: ...18 sec 2 EASIVOICE SYSTEM EASIVOICE BASIC DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS Installation Diagrams...

Отзывы: