EASIVOICE SYSTEM

EASIVOICE

BASIC DIAGRAMS

DOOR PHONE - VIDEO DOOR PHONE SYSTEMS: Installation Diagrams

INTERCOM

 

CONNECTION

 

OF

 

MAXIMUM

 16 

INTERCOM

 

DOOR

 

PHONES

With

 

possibility

 

to

 

answer

 

to

 1 

outdoor

 

station.

 

The

 

intercoms

 

are

 

called

 

separately

 

from

 

theoutdoor

 

station.

 

Possibility

 

of

 

paging

 

service

 

by

 

means

 

of

 

loudspeakers

14

09

14

13+n-7

13+n-8

13+n-9

08

02

14

15

14

14

14

13+n-1

13+n-2

13+n-14

14

2

16

9+n

13+n

01

2

FEATURES

This system allows an intercom service up to 16 intercom door phones 
maximum and with possibility to answer to the calls coming from the 
outdoor station. It is possible to make 4 simultaneous conversations 
among the several intercoms plus one with the outdoor station.
The outdoor station calls the several intercoms separately.
The intercom door phones must all be programmed with two digits, 
i.e. from 01 to 09, from 10 to 19, from 20 to 25, or any other number 
between 01 and 97.

The GENERAL CALL must be connected only if necessary. It is 
recommended to place the amplifi er as close as possible to the power 
supply and to connect them with a shielded cable.

Due to absorption problems, no more than 16 intercoms can be called 
in parallel. It is recommended that the power supply Ref. 926/3 be 
placed at the center of the installation to minimize the cross-talk 
effect.

EQUIPMENT

For said installation (Scheme SC101-0382F) the following:

N. 16   Intercom door phones   

Ref.

 

92

6

/2

N. 1  

Power supply   

 

Ref.

 

92

6

/3

N. 1 

Power supply 

 

for door phone system 

28VA 

Ref.

 

78

6

/

11

 

 

 

28VA 

Ref.

 

78

6

/

1

   

28VA 

Ref.

 

78

6

/

1

4

   

38VA  

Ref.

 

78

6

/38

N. 1  

Call repeater relay 

 

Ref.

 

788/2

1

N. 1  

Amplifi er

  

Possible and not supplied by URMET DOMUS

N. X  

Loudspeakers

  

Possible and not supplied by URMET DOMUS

OUTDOOR STATION REFERENCES 

Mod.

 

Sinthesi

N. 1 

Module with door unit set-up 

Ref.

 11

45/20-/2

1

-/22

N. 1 

Door unit 

 

 

Ref.

 11

45/500

N. X 

Button modules  

 

Ref.

 11

45/

11

-/

1

2-/

1

3-/

1

4

Mod.

 

K-Steel

N. 1 

Module with door unit   

Ref.

 11

55/20-/2

1

-/22A

N. X 

Button modules  

 

Ref.

 11

55/

11

-/

1

2A-/

1

3A-/

1

4A

Mod.

 

725

N. 1 

Panels with 2 buttons   

Ref.

 

725/

1

02

N. 1 

Door unit 

 

 

Ref.

 

5

1

50/500

Domus

 

Aura

 

model

 

N. 1  

Panels with 2 buttons   

Ref.

 111

0/2

N. 1  

Door unit 

 

 

Ref.

 

5

1

50/500

NOTE

:  for correct installation of panels refer to “Door phone and 

Video door phone Product Technical Manual”.

WIRES

As indicated in Scheme SC101-0382F.
13 wires common to all the intercom door phones are necessary, 9 of 
which coming from the power supply Ref. 926/3 and 4 from the push 
button panel, power supply and relay.
Moreover from the push button panel all single call wires start towards 
each intercom.
In case the amplifi er is not used for the GENERAL CALL, do not 
connect the wire L5 among the several intercoms. The common wires 
are reduced to 12.

The electric lock will be released through the relay box Ref. 788/52.

DIAGRAM NOTES 

(see

 

section

 1

)

CY.00

1

CY.002
CY.003
CY.004
VX.008

Содержание EASIVOICE 926

Страница 1: ...sec 2 1 EASIVOICE BASIC DIAGRAMS EASIVOICE SYSTEM DOOR PHONE VIDEO DOOR PHONE SYSTEMS Installation Diagrams EASIVOICE SYSTEM SECTION 2 REV A Download from www urmetdomus com Technical Manuals area...

Страница 2: ...ns with two or more call keys 2 7 BASIC SYSTEM DIAGRAMS INTERCOM CONNECTION OF MAXIMUM 25 INTERCOM DOOR PHONES Possibility of general call service by means of loudspeakers SC101 0313E 2 8 INTERCOM CON...

Страница 3: ...incoming calls from an intercom x to a y one Anyway y can call x and the last one can make outgoing calls Paging function carried out by means of a 5th independent and dedicated line connected to a l...

Страница 4: ...onnect the system wires to the correspondent terminals of the terminal board The connection cable wires to the door phone socket wire are very specific for table installations They must be connected t...

Страница 5: ...nversation cannot last longer than 10 minutes in order to allow other users access to the phone lines Once this time has lapsed an acoustic end of conversation warning signal will be sent to both inte...

Страница 6: ...and can be easily recognized Lift the handset to establish communication the open door key can be used to operate the electric lock at any point When a user engaged in conversation with the outdoor st...

Страница 7: ...can be opened at any time by pressing the door opener key INSTALLATIONS WITH ONE CALL KEY A basic installation is one in which several intercoms type 926 2 are connected to a Call Station and can all...

Страница 8: ...and be connected to it with a shielded cable The power supply Ref 926 3 is sized for an average installation of 25 intercoms A larger number of intercoms will require additional power supplies connec...

Страница 9: ...on Diagrams COLLEGAMENTO INTERCOMUNICANTE DI UN MASSIMO DI INTERCOM CONNECTION OF MAXIMUM 25 INTERCOM DOOR PHONES Possibility of general call service by means of loudspeakers CY 002 VX 008 CY 004 ELEC...

Страница 10: ...be connected to it with a shielded cable The power supply Ref 926 3 is sized for an average installation of 25 intercoms A larger number of intercoms will require additional power supplies connected...

Страница 11: ...DOOR PHONES Possibility of general call service by means of loudspeakers VX 008 CY 002 VX 008 CY 002 VX 008 CY 002 VX 008 CY 002 CY 004 ELECTRONIC INTERCOM SETS Mod 926 IV GROUP OF 22 SETS III GROUP O...

Страница 12: ...blems no more than 16 intercoms can be called in parallel It is recommended that the power supply Ref 926 3 be placed at the center of the installation to minimize the cross talk effect EQUIPMENT For...

Страница 13: ...or station All the intercom door phones are called in parallel from the outdoor station L5 L4 L3 L2 L1 ML 12 D MF L5 L4 L3 L2 L1 ML 12 D MF A CA 1 AP A 2 L5 L4 L3 L2 L1 ML 12 D MF CA 1 AP 2 CY 002 CY...

Страница 14: ...s no more than 16 intercoms can be called in parallel It is recommended that the power supply Ref 926 3 be placed at the center of the installation to minimize the cross talk effect EQUIPMENT For said...

Страница 15: ...r station is equipped with two keys with one of them it calls in parallel the 8 intercoms of group I with the second one those of group II L5 L4 L3 L2 L1 ML 12 D MF L5 L4 L3 L2 L1 ML 12 D MF A CA 1 AP...

Страница 16: ...alk effect EQUIPMENT For said installation Scheme SC101 0382F the following N 16 Intercom door phones Ref 926 2 N 1 Power supply Ref 926 3 N 1 Power supply for door phone system 28VA Ref 786 11 28VA R...

Страница 17: ...tion Possibility of paging service by means of loudspeakers L5 L4 L3 L2 L1 ML 12 D MF CA 1 AP CY 003 2 L5 L4 L3 L2 L1 ML 12 D MF CA 1 AP 2 CY 004 L5 L4 L3 L2 L1 ML 12 D MF CY 002 A A C4 007 C4 008 L U...

Страница 18: ...18 sec 2 EASIVOICE SYSTEM EASIVOICE BASIC DIAGRAMS DOOR PHONE VIDEO DOOR PHONE SYSTEMS Installation Diagrams...

Отзывы: