DS1068-020B
15
LBT20769
2.3.2.2
Partial setting from reader
Proceed as follows to set some of the zones assigned to the reader and to the key:
1.
Insert the key or approach it to the reader when all the green LEDs are off (the procedure will set the zones if some green LEDs
are on during the first cycle). The yellow LED will blink to indicate that the key is being read. All the green LEDs will blink rapidly if
the key is not recognised.
2.
The yellow LED will blink and after a few seconds a cycle will start during which the green LEDs turn on showing the various
combinations in sequence.
3.
Extract/move away the key when the combination of zones to be set is displayed by the LEDs. The possibility of setting each
zone depends on the programming of the reader and on the key used.
4.
The green LEDs indicate the status of the zones assigned to the reader:
LED steady on = zone active;
LED off = zone not active;
LED blinking = at least one zone
associated to the LED is set.
IMPORTANT!
The key will set only the assigned zones and not necessarily all the zones with this procedure.
2.4
UNSETTING PROCEDURE
The alarm system may be unset in various manners, some of which are not EN50131 compliant.
Compliant with EN50131
: unsetting with keypad, through time scheduler and through a customised key input.
Not compliant with EN50131
: unsetting with electronic or proximity key, remote unsetting via PSTN module (available only with
1068/005 control panel), GMS module or IP interface and radio remote control.
The authorisation codes which must be used with keypads are described in
paragraph 5.1 System access codes.
You can unset the entire system and only a few zones if they have been configured in programming.
The user or key must have been previously assigned to the zone during programming in order to operate on it.
2.4.1
Partial or total unsetting with 1068/021 keypad
2.4.1.1
Total unsetting
Proceed as follows to deactivate the entire alarm system:
1.
Press the key
associated with the symbol
to deactivate the intrusion alarm system;
2.
Press the key
associated with the symbol
;
3.
Enter the
USER
code and press
to confirm.
IMPORTANT!
The user will unset only the assigned zones and not necessarily all the zones with this procedure.
2.4.1.2
Partial unsetting
Proceed as follows to deactivate some zones of the alarm system:
1.
Access the
MASTER / INSTALLER / TECH. MANAGER / USER
menu by entering the access code. Press
to confirm;
2.
Select "
System status
" by pressing the key associated with the
or
symbol. Press
to confirm;
3.
Press the key
associated with the symbol
to select the zones to deactivate. Pressing
the zones will be
immediately deactivated;
4.
Press
repeatedly to go back to the upper level menu.
IMPORTANT!
The user will unset only the assigned zones and not necessarily all the zones with this procedure.