background image

LT-3200 Switch

6

A. Config Button:

This button is used to enter the configuration menu on

your switch. When you hold it down for 10-15 seconds, the

LED Bar

(

B

) will light up

Yellow

to indicate you are in config mode. It can also

be used to trigger a favorite scene. After setting up the scene, tap the
button one time to trigger it.

B. RGB LED Notification Bar:

This LED bar serves as a visual display

for whether your lights are on or off and offers visual notifications
based on events that are setup via the Gateway. It can be further
configured, disabling or setting certain brightness levels.

C. Responsive Paddle:

The paddle works in a similar manner to a

standard switch. Pressing up will turn the light on while pressing
down will turn the light off. The switch can be tapped up or down 1-5
times to trigger a specific scene.

D. Air Gap Switch:

This will cut the power to the load your switch is

wired to.

LT-3200 Switch

Including A Switch

Below are the steps for including (pairing) a switch to a Gateway.

Plan, Prep, and Install:

Locate an area to install the switch that is within a recommend distance from the Gateway.

Walls, ceilings, and even furniture may degrade communication between devices.

Remember to turn off the power prior to installation.

Check the signal range by holding the config button for

5-10 seconds

.

[

Green

=

Good Signal

/

Red

=

Poor Signal

]

Including to the Network:

Put the Gateway into

inclusion

mode.

Once started, press the config button on the switch three times and the LED Bar will flash blue. If included
successfully, the bar will turn green. If it turns red, the inclusion process failed.

Switch Not Including? Try an Exclusion:

Put the Gateway into

exclusion

mode.

Once started, press the config button on the switch three times. The LED Bar will turn Green if
excluded successfully.

A

B

C

D

Содержание LT-3200

Страница 1: ...urers All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network Specifications Power 120V AC 60Hz Signal Frequency 908 42 MHz Operating Temperature Range 32 104 F 0 40 C Maximum Load 600W Incandescent 300W LED 150 CFL Approval UL Listed FCC IC Z Wave Plus Certified CAN ICES 003 B MB 003 B For indoor use Specifications subject to c...

Страница 2: ...which is looking for Z Wave devices within its radius Z Wave devices outside this radius will not be found and need to either be moved within the radius or use a repeating device to reach it The second example shows how a repeater can be used to reach a device outside of the initial radius Keep this in mind when building your own network and make sure to use the range estimator below ...

Страница 3: ...rated Concrete Stone 30cm 11 8 20 Aluminum Coating 1mm 0 04 100 Ceiling 30cm 11 8 70 Furniture Non wood 30cm 11 8 40 60 Glass No Metal Coating 5cm 2 0 10 Inner Wall 30cm 11 8 40 Iron Reinforced Concrete 30cm 11 8 30 90 Metal Grid 1mm 0 04 90 Outer Wall 30cm 11 8 60 Plaster 10cm 3 9 10 Pumice 30cm 11 8 10 Red Brick 30cm 11 8 35 Stone 30cm 11 8 30 Wood 30cm 11 8 40 60 ...

Страница 4: ...ly with permanently installed fixtures To install multiple switches remove the tabs as needed Unlike the LT 3200 Switch the heat sink tabs are not used and have no effect on performance Ce gradateur est conçu pour être utilisé uniquement avec des luminaires installés en permanence Pour installer plusieurs gradateurs supprimez les onglets si nécessaire Contrairement au LT 3200 Switch les languettes...

Страница 5: ...l Single Pole Installation Single Switch 3 Way Installation Line Load in Separate Boxes The LT 3200 can be used in a 3 way 4 way lighting installation The Master Load Controller must be defined in URC software Secondary controllers must be defined in URC software Multi Way will not work without prior programming Traveler Wire is not needed for Multi Way configurations of two or more LT 3200s Load ...

Страница 6: ...trigger a specific scene D Air Gap Switch This will cut the power to the load your switch is wired to LT 3200 Switch Including A Switch Below are the steps for including pairing a switch to a Gateway Plan Prep and Install Locate an area to install the switch that is within a recommend distance from the Gateway Walls ceilings and even furniture may degrade communication between devices Remember to ...

Страница 7: ...o confirm the settings were saved SmartStart SmartStart enabled products can be added into a Z Wave network by scanning the Z Wave QR Code present on the product with a controller providing SmartStart inclusion No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity Security 2 DSK The DSK can be found on th...

Страница 8: ...d device 01 Local 02 3 way 03 3 way Local 04 Z Wave Hub 05 Z Wave Hub Local 06 Z Wave Hub 3 way 07 Z Wave Hub Local 3 Way 08 Timer 09 Timer Local 10 Timer 3 Way 11 Timer 3 Way Local 12 Timer Z Wave Hub 13 Timer Z Wave Hub Local 14 Timer Z Wave Hub 3 Way 15 All 01 15 15 1 5 Yes LED Indicator Color Sets the default color of the LED Bar 0 255 160 2 6 Yes LED Indicator Intensity Sets the intensity of ...

Страница 9: ...E_UPDATE_MD Factory Default You may factory reset the switch by holding down the Config Button for twenty 20 or more seconds The LED Bar will turn Red and blink three 3 times to confirm However we recommend using a certified Z Wave controller to remove the device from your network for factory resetting the switch Only use either of these procedures in the event that the network primary controller ...

Страница 10: ... cause undesired operation This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation Thi...